Quantification of vancomycin and clindamycin in human plasma and synovial fluid applying ultra-performance liquid chromatography tandem mass spectrometry

被引:8
作者
Ringeling, L. T. [1 ]
Bahmany, S. [1 ]
van Oldenrijk, J. [2 ]
Bos, P. K. [2 ]
Veltman, E. S. [2 ]
Koch, B. C. P. [1 ,3 ]
机构
[1] Erasmus MC, Univ Med Ctr Rotterdam, Dept Hosp Pharm, Rotterdam, Netherlands
[2] Erasmus MC, Univ Med Ctr Rotterdam, Dept Orthoped, Rotterdam, Netherlands
[3] Erasmus MC, Univ Med Ctr Rotterdam, Dept Hosp Pharm, Wytemaweg 80,POB 2040, NL-2015 CN Rotterdam, Netherlands
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2022年 / 1212卷
关键词
Vancomycin; Clindamycin; Periprosthetic joint infection; Synovial fluid; Liquid; -chromatography; Mass spectrometry; JOINT REPLACEMENT; PROTEIN-BINDING; HUMAN SERUM; BONE; INFECTION; PHARMACOKINETICS; PENETRATION; INJECTION; PHOSPHATE; SAMPLES;
D O I
10.1016/j.jchromb.2022.123493
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Periprosthetic joint infection is a challenging infection involving the joint prosthesis and adjacent tissue, such as synovial fluid, synovial tissue, and bone tissue. The current treatment consists of multiple surgical revisions and long-term antibiotic therapy. Treatment failure can cause poor functional outcome and reduced quality of life. Further research on the extent of antibiotic penetration into the infected tissues is of great importance. Our work aimed to develop and validate a novel ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for the determination of the commonly administered antibiotics vancomycin and clindamycin in plasma and synovial fluid. An extraction procedure consisting of zinc sulfate precipitation and dilution with eluent was used for both analytes. Chromatographic separation was performed on a Waters Acquity UPLC HSS T3 C18 column (1.8 mu m, 2.1 x 100 mm), and quantification was carried out by a Waters Xevo TQ-S micro mass spectrometer. Stable isotope-labeled vancomycin-d10 served as internal standard. The method validation was performed based on the guidelines of the EMA and FDA. The calibration curves were linear over the range of 0.5-50 mg/L, with a coefficient of determination above 0.990. The validation results for precision and accuracy, specificity, matrix effects and stability were all within the acceptance range. An accurate and rapid method for the simultaneous quantification of vancomycin and clindamycin in human plasma and synovial fluid on the UPLC-MS/MS was developed, optimized and validated. The analysis has a run time of 5.2 min and 50 mu L sample volume is needed. This developed method was successfully applied in eight patients with PJI and is suitable to determine the exposure of antibiotics in plasma and synovial fluid in patients during current PK/PD studies.
引用
收藏
页数:10
相关论文
共 42 条
[1]   Prosthetic Joint Infections: an Update [J].
Abad, C. L. ;
Haleem, A. .
CURRENT INFECTIOUS DISEASE REPORTS, 2018, 20 (07)
[2]  
[Anonymous], 2001, Guidance for industry, bioanalytical method validation
[3]   A Normative Study of the Synovial Fluid Proteome from Healthy Porcine Knee Joints [J].
Bennike, Tue ;
Ayturk, Ugur ;
Haslauer, Carla M. ;
Froehlich, John W. ;
Proffen, Benedikt L. ;
Barnaby, Omar ;
Birkelund, Svend ;
Murray, Martha M. ;
Warman, Matthew L. ;
Stensballe, Allan ;
Steen, Hanno .
JOURNAL OF PROTEOME RESEARCH, 2014, 13 (10) :4377-4387
[4]   Simultaneous analysis of antibiotics in biological samples by ultra high performance liquid chromatography-tandem mass spectrometry [J].
Cazorla-Reyes, Rocio ;
Romero-Gonzalez, Roberto ;
Garrido Frenich, Antonia ;
Rodriguez Maresca, Manuel Angel ;
Martinez Vidal, Jose Luis .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 89 :203-212
[5]   Pharmacokinetic variability of clindamycin and influence of rifampicin on clindamycin concentration in patients with bone and joint infections [J].
Curis, Emmanuel ;
Pestre, Vincent ;
Jullien, Vincent ;
Eyrolle, Luc ;
Archambeau, Denis ;
Morand, Philippe ;
Gatin, Laure ;
Karoubi, Matthieu ;
Pinar, Nicolas ;
Dumaine, Valerie ;
Van, Jean-Claude Nguyen ;
Babinet, Antoine ;
Anract, Philippe ;
Salmon, Dominique .
INFECTION, 2015, 43 (04) :473-481
[6]   Synovial Fluid Aspirates Diluted with Saline or Blood Reduce the Sensitivity of Traditional and Contemporary Synovial Fluid Biomarkers [J].
Deirmengian, Carl ;
Feeley, Scott ;
Kazarian, Gregory S. ;
Kardos, Keith .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2020, 478 (08) :1805-1813
[7]  
Deodhar S D, 1972, Curr Med Res Opin, V1, P108, DOI 10.1185/03007997209111153
[8]   Continuous high-dose vancomycin combination therapy for methicillin-resistant staphylococcal prosthetic hip infection: a prospective cohort study [J].
Dubee, V. ;
Zeller, V. ;
Lhotellier, L. ;
Kitzis, M. -D. ;
Ziza, J. -M. ;
Mamoudy, P. ;
Desplaces, N. .
CLINICAL MICROBIOLOGY AND INFECTION, 2013, 19 (02) :E98-E105
[9]  
Eshkenazi A U, 2001, Am J Knee Surg, V14, P221
[10]   COMPARISON OF THE PHARMACOKINETIC PROPERTIES OF VANCOMYCIN, LINEZOLID, TIGECYCLIN, AND DAPTOMYCIN [J].
Estes, Kerry S. ;
Derendorf, Hartmut .
EUROPEAN JOURNAL OF MEDICAL RESEARCH, 2010, 15 (12) :533-543