Feasibility analysis and feature comparison of cold thermal energy storage for off-grid PV air-conditioned buildings in the tropics

被引:32
作者
Hu, Liang [1 ,2 ]
Liu, Yanfeng [1 ,2 ]
Wang, Dengjia [1 ,2 ]
Luo, Xi [1 ,2 ]
Liu, Huaican [3 ,4 ]
机构
[1] Xian Univ Architecture & Technol, State Key Lab Green Bldg Western China, 13 Yanta Rd, Xian 710055, Peoples R China
[2] Xian Univ Architecture & Technol, Sch Bldg Serv Sci & Engn, 13 Yanta Rd, Xian 710055, Peoples R China
[3] State Key Lab Air Conditioning Equipment & Syst E, 789 Jinji Rd, Zhuhai 519070, Peoples R China
[4] Gree Elect Appliances Inc Zhuhai, West Jinji Rd, Zhuhai 519070, Peoples R China
基金
中国国家自然科学基金;
关键词
Off-grid PV system; Air-conditioned building; Cold thermal energy storage; Economic optimization; Tropical regions; CHILLED WATER STORAGE; DEMAND-SIDE MANAGEMENT; BATTERY STORAGE; ECONOMIC-ANALYSIS; RENEWABLE ENERGY; COOLING SYSTEM; SOLAR-PV; OPTIMIZATION; LOAD; TIME;
D O I
10.1016/j.enconman.2021.115176
中图分类号
O414.1 [热力学];
学科分类号
摘要
Cold thermal energy storage (CTES) is a cost-efficient storage approach for PV powered air-conditioning systems in tropical buildings. However, the feasibility and performance of different CTESs, including chilled water storage, ice storage, PCM cooling storage, and building thermal storage, are still unclear for off-grid PV airconditioned buildings. In this study, an off-grid PV system with battery and CTES is proposed, including the operation strategy to manage the energy-storage process. To implement all CTES-types, a co-simulation model, which integrates the system model with the ARX (autoregressive with exogenous input) cooling-load model, is constructed to enable the interaction between supply- and demand-side. Based on the minimization of net present cost and the constraint of a certain required solar fraction, an optimization method is developed to find the optimal systemconfiguration. Moreover, an office, a hotel, and a residence are selected for a case study. The results indicate that CTES is feasible for higher solar fraction. The feasibility ranking of building type is (from high to low): residence, hotel, and office. In the most suitable case (residence), the maximum reduction of system costs (compared to battery-only system) is 49.76%, 41.77%, 44.31%, and 22.78%, respectively, for chilled-water storage, ice storage, PCM cooling storage, and building thermal storage. These values are 22.48%, 12.00%, 17.42%, 2.60% for the hotel, and 19.26%, 11.57%, 13.64%, 4.06% for the office. In addition, the sensitivity analysis shows that the increasing cost of both PV-array and CTES-device affects the feasibility of CTES negatively, while the increasing battery cost is a positive factor. Compared to the cost of the PV-array and the CTES-device, the battery cost represents the most significant effect-factor for feasibility.
引用
收藏
页数:26
相关论文
共 71 条
[1]   Dynamic simulation of an integrated solar-driven ejector based air conditioning system with PCM cold storage [J].
Allouche, Yosr ;
Varga, Szabolcs ;
Bouden, Chiheb ;
Oliveira, Armando C. .
APPLIED ENERGY, 2017, 190 :600-611
[2]   Life cycle assessment and economic analysis of residential air conditioning in Saudi Arabia [J].
Almutairi, Kamel ;
Thoma, Greg ;
Burek, Jasmina ;
Algarni, Salem ;
Nutter, Darin .
ENERGY AND BUILDINGS, 2015, 102 :370-379
[3]   An effectiveness-NTU model of a packed bed PCM thermal storage system [J].
Amin, N. A. M. ;
Belusko, M. ;
Bruno, F. .
APPLIED ENERGY, 2014, 134 :356-362
[4]   Effectiveness-NTU correlation for low temperature PCM encapsulated in spheres [J].
Amin, N. A. M. ;
Bruno, F. ;
Belusko, M. .
APPLIED ENERGY, 2012, 93 :549-555
[5]   Thermal energy storage coupled with PV panels for demand side management of industrial building cooling loads [J].
Arteconi, Alessia ;
Ciarrocchi, Eleonora ;
Pan, Quanwen ;
Carducci, Francesco ;
Comodi, Gabriele ;
Polonara, Fabio ;
Wang, Ruzhu .
APPLIED ENERGY, 2017, 185 :1984-1993
[6]   Designing an optimized configuration for a hybrid PV/Diesel/Battery Energy System based on metaheuristics: A case study on Gobi Desert [J].
Ashraf, Muhammad Aqeel ;
Liu, Zhenling ;
Alizadeh, As'ad ;
Nojavan, Sayyad ;
Jermsittiparsert, Kittisak ;
Zhang, Dangquan .
JOURNAL OF CLEANER PRODUCTION, 2020, 270
[7]   Techno-economic analysis of a grid-connected PV/battery system using the teaching-learning-based optimization algorithm [J].
Ashtiani, Mina Najafi ;
Toopshekan, Ashkan ;
Astaraei, Fatemeh Razi ;
Yousefi, Hossein ;
Maleki, Akbar .
SOLAR ENERGY, 2020, 203 :69-82
[8]   Multi-objective optimization of grid-connected PV-wind hybrid system considering reliability, cost, and environmental aspects [J].
Barakat, Shimaa ;
Ibrahim, Haitham ;
Elbaset, Adel A. .
SUSTAINABLE CITIES AND SOCIETY, 2020, 60
[9]   Storing surplus solar energy in low temperature thermal storage for refrigeration applications [J].
Beck, Michael ;
Mueller, Karsten ;
Arlt, Wolfgang .
ENERGY AND BUILDINGS, 2016, 122 :192-198
[10]   Energy and economic analysis of a building air-conditioner with a phase change material (PCM) [J].
Chaiyat, Nattaporn .
ENERGY CONVERSION AND MANAGEMENT, 2015, 94 :150-158