The shear strength of concrete beams hybrid-reinforced with GFRP bars and steel bars in main reinforcement without shear reinforcement

被引:2
作者
Shoeib, Ata El-kareim [1 ]
Arafa, Ahmed Noureldean [2 ]
Sedawy, Ahmed EL-sayed [1 ]
EL-Hashmy, Awad M. [1 ]
机构
[1] Helwan Univ, Fac Engn Mataria, Helwan, Egypt
[2] Sohag Univ, Fac Engn, Sohag, Egypt
关键词
Hybrid steel bars with GFRP bars in main reinforcement; reinforcement ratio; shear span-to-depth ratio; depth of the beam; and concrete compressive strength; PREDICTION; BOND;
D O I
10.1515/cls-2022-0013
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
The investigation of the structural performance of reinforced concrete members in the construction process has become a critical issue for Hybrid GFRP bars with steel bars. The ultimate concrete shear strength of reinforced concrete beams contains both GFRP bars and Steel bars in main reinforcement are a main task of work. This paper examines the effect of sharing the fiber-reinforced polymer (FRP) bars with steel bars for reinforced concrete (RC) structures on the concrete shear strength of RC beams. Fourteen RC beams without shear reinforcement were constructed and tested up to failure. The test beams included two steel-RC beams, one GFRP-RC beam, and eleven steel bars and GFRP bars (hybrid GFRP/steel)-RC beams. The main parameters were the reinforcement ratio, shear span to depth ratio, depth of the beam, concrete compressive strength, and compression reinforcement. The test results are presented in terms of crack patterns, failure modes, load-deflection, and load-strain behavior. The test results showed that hybrid GFRP/steel bars causing significant improvement in the ductility with reduction of the deformation comparing with an only steel bar in main steel in tested beams. The dowel action can play a major role in the process by which shear is carried in a beam. Finally, the initial proposal equation that calculates the shear strength of hybrid reinforced elements can serve as a guideline for the introduction of hybrid bars (GFRP and Steel) at the main reinforcement in RC beams.
引用
收藏
页码:146 / 162
页数:17
相关论文
共 46 条
[11]   Designing against size effect on shear strength of reinforced concrete beams without stirrups: I. Formulation [J].
Bazant, ZP ;
Yu, Q .
JOURNAL OF STRUCTURAL ENGINEERING, 2005, 131 (12) :1877-1885
[12]  
Budvytis M., 2018, ENG STRUCTURES TECHN, V10, P46
[13]  
Canadian Standard Association (CSA), 2002, S80602 CAN STAND ASS
[14]   A FE-based limit analysis approach for concrete elements reinforced with FRP bars [J].
De Domenico, D. ;
Pisano, A. A. ;
Fuschi, P. .
COMPOSITE STRUCTURES, 2014, 107 :594-603
[15]  
Gastebled OJ, 2001, ACI STRUCT J, V98, P184
[16]  
GUSTAFSSON PJ, 1988, ACI STRUCT J, V85, P286
[17]  
Hegger J., 2009, P 9 INT S FIB REINF
[18]  
Houde J., 1974, Spec. Publ, V42, P103
[19]  
Jaeger L.G., 1997, P 3 INT S NONM FRP R, P551
[20]  
Jenq Y.S., 1989, ACI Special Publication, V118, P237