Evaluation of Deformable Image Registration for Lung Motion Estimation Using Hyperpolarized Gas Tagging MRI

被引:0
|
作者
Huang, Q.
Zhang, Y.
Liu, Y.
Hu, L.
Miller, W.
Yin, F.
Cai, J.
机构
关键词
Lungs; Motion estimation; Image registration; Vector fields; Medical magnetic resonance imaging; Flow visualization; Protons; Optical flow; Three dimensional image processing;
D O I
10.1118/1.4889214
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
MO-G-18C-0
引用
收藏
页数:2
相关论文
共 50 条
  • [1] Evaluate Deformable Image Registration for the Lungs Using Hyperpolarized Gas Tagging MRI
    Liu, Y.
    Miller, W.
    Yin, F.
    Cai, J.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [2] Physiological Modeling of Lung Motion Based On Hyperpolarized Gas Tagging MRI
    Cui, T.
    Hu, L.
    Miller, W.
    Yin, F.
    Cai, J.
    MEDICAL PHYSICS, 2015, 42 (06) : 3733 - 3734
  • [3] Estimation of Lung Motion Using Deformable Image Registration Based on Compressible Flow
    Li, Min
    Zhang, Limei
    Lian, Zhichao
    Xiang, Zhikang
    Xiao, Liang
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2017, 7 (07) : 1667 - 1670
  • [4] An initial investigation of hyperpolarized gas tagging magnetic resonance imaging in evaluating deformable image registration-based lung ventilation
    Cui, Taoran
    Miller, G. Wilson
    Mugler, John P., III
    Cates, Gordon D., Jr.
    Mata, Jaime F.
    de Lange, Eduard E.
    Huang, Qijie
    Altes, Talissa A.
    Yin, Fang-Fang
    Cai, Jing
    MEDICAL PHYSICS, 2018, 45 (12) : 5535 - 5542
  • [5] Evaluation of DIR-Based Lung Ventilation Imaging Against Hyperpolarized Gas Ventilation MRI and Hyperpolarized Gas Tagging MRI
    Duarte, I.
    Lam, S.
    Cui, T.
    Miller, G.
    Garrison, W.
    Mugler, J., III
    Shim, M.
    Cates, G.
    Yin, F.
    Cai, J.
    MEDICAL PHYSICS, 2019, 46 (06) : E502 - E502
  • [6] A method for quantitative analysis of regional lung ventilation using deformable image registration of CT and hybrid hyperpolarized gas/1H MRI
    Tahir, Bilal A.
    Swift, Andrew J.
    Marshall, Helen
    Parra-Robles, Juan
    Hatton, Matthew Q.
    Hartley, Ruth
    Kay, Richard
    Brightling, Christopher E.
    Vos, Wim
    Wild, Jim M.
    Ireland, Rob H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (23): : 7267 - 7277
  • [7] A hybrid proton and hyperpolarized gas tagging MRI technique for lung respiratory motion imaging: a feasibility study
    Hu, Lei
    Huang, Qijie
    Cui, Taoran
    Duarte, Isabella
    Miller, G. Wilson
    Mugler, John P., III
    Cates, Gordon D., Jr.
    Matas, Jaime F.
    de Lange, Eduard E.
    Altes, Talissa A.
    Yin, Fang-Fang
    Cai, Jing
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (10):
  • [8] Deformable Image Registration of Liver With Consideration of Lung Sliding Motion
    Xie, Yaoqin
    Chao, Ming
    Xiong, Guanglei
    MEDICAL PHYSICS, 2011, 38 (10) : 5351 - 5361
  • [9] Assessing Inter and Intrafraction Target Motion in Lung SBRT Using Deformable Image Registration
    Liang, J.
    Lack, D.
    Liu, Q.
    Sandhu, R.
    Benedetti, L.
    Stevens, C.
    Yan, D.
    MEDICAL PHYSICS, 2020, 47 (06) : E408 - E408
  • [10] Evaluation of the accuracy of deformable image registration on MRI with a physical phantom
    Wu, Richard Y.
    Liu, Amy Y.
    Yang, Jinzhong
    Williamson, Tyler D.
    Wisdom, Paul G.
    Bronk, Lawrence
    Gao, Song
    Grosshan, David R.
    Fuller, David C.
    Gunn, Gary B.
    Ronald Zhu, X.
    Frank, Steven J.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (01): : 166 - 173