Integration of maXs-type microcalorimeter detectors for high-resolution x-ray spectroscopy into the experimental environment at the CRYRING@ESR electron cooler

被引:10
|
作者
Pfaefflein, Ph [1 ,2 ,3 ]
Allgeier, S. [4 ]
Bernitt, S. [1 ,2 ,3 ]
Fleischmann, A. [4 ]
Friedrich, M. [4 ]
Hahn, Ch [1 ,2 ]
Hengstler, D. [4 ]
Herdrich, M. O. [1 ,2 ,3 ]
Kalinin, A. [1 ]
Kroeger, F. M. [2 ,3 ]
Kuntz, P. [4 ]
Lestinsky, M. [1 ]
Loeher, B. [1 ]
Menz, E. B. [1 ,2 ,3 ]
Over, T. [2 ,3 ]
Spillmann, U. [1 ]
Weber, G. [1 ,2 ]
Zhu, B. [1 ,2 ,3 ]
Enss, Ch [4 ,5 ]
Stoehlker, Th [1 ,2 ,3 ]
机构
[1] GSI Helmholtzzentrum Schwerionenforsch, Planckstr 1, D-64291 Darmstadt, Germany
[2] Helmholtz Inst Jena, Frobelstieg 3, D-07743 Jena, Germany
[3] Friedrich Schiller Univ, Inst Opt & Quantum Elect, Max Wien Pl 1, D-07743 Jena, Germany
[4] Heidelberg Univ, Kirchhoff Inst Phys, Neuenheimer Feld 227, D-69120 Heidelberg, Germany
[5] Karlsruhe Inst Technol, Inst Data Proc & Elect, Hermann von Helmholtz Pl 1, D-76344 Eggenstein Leopoldshafen, Germany
基金
欧洲研究理事会;
关键词
microcalorimeter; precision x-ray spectroscopy; heavy highly charged ions; ion storage ring; metallic magnetic calorimeter; coincidence measurement; RELATIVISTIC HEAVY-IONS; PHYSICS; COLLISIONS; FIELDS;
D O I
10.1088/1402-4896/ac93be
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
We report on the first integration of novel magnetic microcalorimeter detectors (MMCs), developed within SPARC (Stored Particles Atomic Physics Research Collaboration), into the experimental environment of storage rings at GSI(6), Darmstadt, namely at the electron cooler of CRYRING@ESR. Two of these detector systems were positioned at the 0 degrees and 180 degrees view ports of the cooler section to obtain high-resolution x-ray spectra originating from a stored beam of hydrogen-like uranium interacting with the cooler electrons. While previous test measurements with microcalorimeters at the accelerator facility of GSI were conducted in the mode of well-established stand-alone operation, for the present experiment we implemented several notable modifications to exploit the full potential of this type of detector for precision x-ray spectroscopy of stored heavy ions. Among these are a new readout system compatible with the multi branch system data acquisition platform of GSI, the synchronization of a quasi-continuous energy calibration with the operation cycle of the accelerator facility, as well as the first exploitation of the maXs detectors' time resolution to apply coincidence conditions for the detection of photons and charge-changed ions.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] A high-resolution asymmetric von Hamos spectrometer for low-energy X-ray spectroscopy at the CRYRING@ESR electron cooler
    Jagodzinski, P.
    Banas, D.
    Pajek, M.
    Kubala-Kukus, A.
    Jablonski, L.
    Stabrawa, I.
    Szary, K.
    Sobota, D.
    Warczak, A.
    Gumberidze, A.
    Beyer, H. F.
    Lestinsky, M.
    Weber, G.
    Stoehlker, Th.
    Trassinelli, M.
    JOURNAL OF INSTRUMENTATION, 2023, 18 (11)
  • [2] Concept and simulations of a high-resolution asymmetric von Hamos X-ray spectrometer for CRYRING@ESR electron cooler
    Jagodzinski, P.
    Banas, D.
    Pajek, M.
    Warczak, A.
    Beyer, H. F.
    Gumberidze, A.
    Weber, G.
    Stoehlker, Th
    Trassinelli, M.
    31ST INTERNATIONAL CONFERENCE ON PHOTONIC, ELECTRONIC AND ATOMIC COLLISIONS (ICPEAC XXXI), 2020, 1412
  • [3] maXs: Microcalorimeter Arrays for High-Resolution X-Ray Spectroscopy at GSI/FAIR
    Pies, C.
    Schaefer, S.
    Heuser, S.
    Kempf, S.
    Pabinger, A.
    Porst, J. -P.
    Ranitsch, P.
    Foerster, N.
    Hengstler, D.
    Kampkoetter, A.
    Wolf, T.
    Gastaldo, L.
    Fleischmann, A.
    Enss, C.
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2012, 167 (3-4) : 269 - 279
  • [4] maXs: Microcalorimeter Arrays for High-Resolution X-Ray Spectroscopy at GSI/FAIR
    C. Pies
    S. Schäfer
    S. Heuser
    S. Kempf
    A. Pabinger
    J.-P. Porst
    P. Ranitsch
    N. Foerster
    D. Hengstler
    A. Kampkötter
    T. Wolf
    L. Gastaldo
    A. Fleischmann
    C. Enss
    Journal of Low Temperature Physics, 2012, 167 : 269 - 279
  • [5] SEMICONDUCTOR DRIFT DETECTORS FOR HIGH-RESOLUTION X-RAY SPECTROSCOPY
    CASTOLDI, A
    SAMPIETRO, M
    SENSORS AND ACTUATORS A-PHYSICAL, 1992, 31 (1-3) : 245 - 249
  • [6] SILICON RADIATION DETECTORS FOR HIGH-RESOLUTION X-RAY SPECTROSCOPY
    PIGNATEL, GU
    INFORMACIJE MIDEM-JOURNAL OF MICROELECTRONICS ELECTRONIC COMPONENTS AND MATERIALS, 1995, 25 (02): : 89 - 97
  • [7] Superconducting tunnel junctions as detectors for high-resolution x-ray spectroscopy
    Huber, M
    Angloher, G
    Hollerith, C
    Ruedig, A
    Jochum, J
    Potzel, W
    von Feilitzsch, F
    X-RAY SPECTROMETRY, 2004, 33 (04) : 253 - 255
  • [8] Silicon Drift Detectors and CUBE Preamplifiers for High-Resolution X-ray Spectroscopy
    Quaglia, R.
    Bombelli, L.
    Busca, P.
    Fiorini, C.
    Occhipinti, M.
    Giacomini, G.
    Ficorella, F.
    Picciotto, A.
    Piemonte, C.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2015, 62 (01) : 221 - 227
  • [9] Application of Low-Temperature Detectors to High-Resolution X-ray Spectroscopy
    Kilbourne, Caroline A.
    LOW TEMPERATURE DETECTORS LTD 13, 2009, 1185 : 419 - 425
  • [10] HIGH-RESOLUTION X-RAY SPECTROSCOPY WITH SILICON DRIFT DETECTORS AND INTEGRATED ELECTRONICS
    BERTUCCIO, G
    SAMPIETRO, M
    FAZZI, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 322 (03): : 538 - 542