Biomechanical Study on Three Screw-Based Atlantoaxial Fixation Techniques: A Finite Element Study

被引:3
作者
Erbulut, Deniz Ufuk [1 ]
Mumtaz, Muzammil [2 ]
Zafarparandeh, Iman [3 ]
Ozer, Ali Fahir [4 ]
机构
[1] Metro North Hosp & Hlth Serv, Herston Biofabricat Inst, Brisbane, Qld, Australia
[2] Univ Toledo, Engn Ctr Orthopaed Res Excellence ECORE, Toledo, OH USA
[3] Istanbul Medipol Univ, Dept Biomed Engn, Istanbul, Turkey
[4] Koc Univ, Dept Neurosurg, Sch Med, Istanbul, Turkey
关键词
Atlantoaxial fixation; Lateral mass screw; Pedicle screws; Screw-based technique; Transarticular screw; UPPER CERVICAL-SPINE; LAMINAR SCREWS; PEDICLE; COMPLICATIONS; COMPLEX; MODEL; TRANSLAMINAR; SUITABILITY; FUSION;
D O I
10.31616/asj.2021.0270
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Study Design: This is a finite element study. Purpose: This study is aimed to compare the biomechanical behaviors of three screw-based atlantoaxial fixation techniques. Overview of Literature: Screw-based constructs that are widely used to stabilize the atlantoaxial joint come with their own challenges in surgery. Clinical and in vitro studies have compared the effectiveness of screw-based constructs in joint fixation. Nevertheless, there is limited information regarding the biomechanical behavior of these constructs, such as the stresses and strains they experience. Methods: A finite element model of the upper cervical spine was developed. A type II dens fracture was induced in the intact model to produce the injured model. The following three constructs were simulated on the intact and injured models: transarticular screw (C1-C2TA), lateral mass screw in C1 and pedicle screw in C2 (C1LM1-C2PD), and lateral mass screw in C1 and translaminar screw in C2 (C1LM1-C2TL). Results: In the intact model, flexion-extension range of motion (ROM) was reduced by up to 99% with C11-C2TA and 98% with C1LM1-C2PD and C1LM1-C2TL. The lateral bending ROM in the intact model was reduced by 100%, 95%, and 75% with C11-C2TA, C1LM1-C2PD, and C1LM1-C2TL, respectively. The axial rotation ROM in the intact model was reduced by 99%, 98%, and 99% with C11-C2TA, C1LM1-C2PD, and C1LM1-C2TL, respectively. The largest maximum von Mises stress was predicted for C1LM1-C2TL (332 MPa) followed by C1LM1-C2PD (307 MPa) and C11-C2TA (133 MPa). Maximum stress was predicted to be at the lateral mass screw head of the C1LM1-C2TL construct. Conclusions: Our model indicates that the biomechanical stability of the atlantoaxial joint in lateral bending with translaminar screws is not as reliable as that with transarticular and pedicle screws. Translaminar screws experience large stresses that may lead to failure of the construct before the required bony fusion occurs.
引用
收藏
页码:831 / 838
页数:8
相关论文
共 30 条
  • [1] PEDIATRIC ATLANTOAXIAL INSTABILITY PRESENTING AS CEREBRAL AND CEREBELLAR INFARCTS
    BHATNAGAR, M
    SPONSELLER, PD
    CARROLL, C
    TOLO, VT
    [J]. JOURNAL OF PEDIATRIC ORTHOPAEDICS, 1991, 11 (01) : 103 - 107
  • [2] Development of a finite element model of the upper cervical spine and a parameter study of ligament characteristics
    Brolin, K
    Halldin, P
    [J]. SPINE, 2004, 29 (04) : 376 - 385
  • [3] Lateral Mass Screw Fixation in the Cervical Spine A Systematic Literature Review
    Coe, Jeffrey D.
    Vaccaro, Alexander R.
    Dailey, Andrew T.
    Skolasky, Richard L., Jr.
    Sasso, Richard C.
    Ludwig, Steven C.
    Brodt, Erika D.
    Dettori, Joseph R.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2013, 95A (23) : 2136 - 2143
  • [4] Seven Years of Experience With C2 Translaminar Screw Fixation: Clinical Series and Review of the Literature
    Dorward, Ian G.
    Wright, Neill M.
    [J]. NEUROSURGERY, 2011, 68 (06) : 1491 - 1499
  • [5] Application of an asymmetric finite element model of the C2-T1 cervical spine for evaluating the role of soft tissues in stability
    Erbulut, D. U.
    Zafarparandeh, I.
    Lazoglu, I.
    Ozer, A. F.
    [J]. MEDICAL ENGINEERING & PHYSICS, 2014, 36 (07) : 915 - 921
  • [6] Gallie WE., 1939, AM J SURG, V46, P495, DOI DOI 10.1016/S0002-9610(39)90309-0
  • [7] COMPLICATIONS OF SUBLAMINAR WIRING
    GEREMIA, GK
    KIM, KS
    CERULLO, L
    CALENOFF, L
    [J]. SURGICAL NEUROLOGY, 1985, 23 (06): : 629 - 634
  • [8] Constructs incorporating intralaminar C2 screws provide rigid stability for Atlantoaxial fixation
    Gorek, J
    Acaroglu, E
    Berven, S
    Yousef, A
    Puttlitz, CM
    [J]. SPINE, 2005, 30 (13) : 1513 - 1518
  • [9] Posterior C1-C2 fusion with polyaxial screw and rod fixation
    Harms, J
    Melcher, RP
    [J]. SPINE, 2001, 26 (22) : 2467 - 2471
  • [10] COMPLICATIONS OF POSTERIOR CERVICAL PLATING
    HELLER, JG
    SILCOX, DH
    SUTTERLIN, CE
    [J]. SPINE, 1995, 20 (22) : 2442 - 2448