Design of a hydrodynamic cavitation system for the extraction and detection of Escherichia coli (O157:H7) from ground beef

被引:2
作者
Patel, Dhruv [1 ]
Jayamohan, Harikrishnan [1 ]
Nze, Ugochukwu [1 ]
Lambert, Christopher [1 ]
Feng, Haidong [1 ]
Mahmood, Tawsif [1 ]
Gale, Bruce [1 ,2 ]
Sant, Himanshu [1 ,2 ]
机构
[1] Univ Utah, Dept Mech Engn, Salt Lake City, UT 84112 USA
[2] Espira Inc, 825N 300W Suite N-223, Salt Lake City, UT 84103 USA
关键词
E. coli O157:H7 isolation; Cavitation; Stomaching; Pathogen recovery; Electrochemical detection; ELECTROCHEMICAL DETECTION; FOOD; QUANTIFICATION; DISINFECTION; STRAWBERRIES;
D O I
10.1016/j.snb.2022.132370
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Pathogen detection in food is essential for mitigating a community's adverse health and economic impacts. Pathogen extraction and release from food matrices is a bottleneck for current detection systems. Homogenization via stomaching is the best available method for pathogen extraction from meat. However, the recovery of pathogens is limited. This paper presents the benefit of adding seven minutes of cavitation to the stand-alone stomaching method for the homogenization of ground beef and subsequent downstream detection of E. coli O157:H7 in spiked ground beef. To the best of our knowledge, this is the first instance of the utilization of stomaching followed by cavitation for the extraction of pathogens from food matrices. In this study, the homogenization of ground beef is characterized using particle size measurements. Results show that homogenization of the ground beef increases as cavitation intensity increases, leading to an enhanced release of E. coli O157:H7 compared to stand-alone stomaching. However, much higher intensity cavitation (cavitation number = 0.84) would damage E. coli O157:H7, leading to a 20.5% reduction in the viable E. coli O157:H7, adversely affecting downstream detection. Therefore, cavitation parameters were optimized to maximize the release of E. coli O157:H7 from ground beef and concomitantly minimize the damage to the pathogen. The addition of seven-minute cavitation to stomaching was 74 % more effective than the current gold standard, stand-alone stomaching for detecting E. coli O157:H7 from ground beef. The work presented here has substantial implications for extracting various pathogens from different types of food.
引用
收藏
页数:9
相关论文
共 39 条
[1]   Electrochemical detection of Salmonella using gold nanoparticles [J].
Afonso, Andre S. ;
Perez-Lopez, Briza ;
Faria, Ronaldo C. ;
Mattoso, Luiz H. C. ;
Hernandez-Herrero, Manuela ;
Xavier Roig-Sagues, Artur ;
Maltez-da Costa, Marisa ;
Merkoci, Arben .
BIOSENSORS & BIOELECTRONICS, 2013, 40 (01) :121-126
[2]  
Andrews W H., 2003, Bacteriological Analytical Manual (BAM)
[3]  
[Anonymous], An Overview of Ground Beef at Retail and Food Service
[4]  
[Anonymous], 2014, MULT OUTBR SHIG TOX
[5]  
[Anonymous], 2020, Foodborne pathogens
[6]   Highly sensitive detection of pathogen Escherichia coli O157:H7 by electrochemical impedance spectroscopy [J].
Barreiros dos Santos, M. ;
Agusil, J. P. ;
Prieto-Simon, B. ;
Sporer, C. ;
Teixeira, V. ;
Samitier, J. .
BIOSENSORS & BIOELECTRONICS, 2013, 45 :174-180
[7]   Comparison and optimization of detection methods for noroviruses in frozen strawberries containing different amounts of RT-PCR inhibitors [J].
Bartsch, Christina ;
Szabo, Kathrin ;
Mai Dinh-Thanh ;
Schrader, Christina ;
Trojnar, Eva ;
Johne, Reimar .
FOOD MICROBIOLOGY, 2016, 60 :124-130
[8]  
Beach C, 2021, USDA INVESTIGATES NE
[9]   Electrochemical Detection of E-coli O157:H7 in Water after Electrocatalytic and Ultraviolet Treatments Using a Polyguanine-Labeled Secondary Bead Sensor [J].
Beeman, Michael G. ;
Nze, Ugochukwu C. ;
Sant, Himanshu J. ;
Malik, Hammad ;
Mohanty, Swomitra ;
Gale, Bruce K. ;
Carlson, Krista .
SENSORS, 2018, 18 (05)
[10]   Sample Preparation: The Forgotten Beginning [J].
Brehm-Stecher, Byron ;
Young, Crarles ;
Jaykus, Lee-Ann ;
Tortorello, Mary Lou .
JOURNAL OF FOOD PROTECTION, 2009, 72 (08) :1774-1789