Toward clinically usable CAD for lung cancer screening with computed tomography

被引:10
|
作者
Brown, Matthew S. [1 ]
Lo, Pechin [1 ]
Goldin, Jonathan G. [1 ]
Barnoy, Eran [1 ]
Kim, Grace Hyun J. [1 ]
McNitt-Gray, Michael F. [1 ]
Aberle, Denise R. [1 ]
机构
[1] Univ Calif Los Angeles, David Geffen Sch Med, Dept Radiol Sci, Ctr Comp Vis & Imaging Biomarkers, 924 Westwood Blvd,Suite 615, Los Angeles, CA 90024 USA
关键词
Lung cancer; Multiple pulmonary nodules; Computer-assisted diagnosis; Early detection of cancer; X-ray computerized axial tomography; NODULE DETECTION; AIDED DIAGNOSIS; CHEST CT;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives The purpose of this study was to define clinically appropriate, computer-aided lung nodule detection (CAD) requirements and protocols based on recent screening trials. In the following paper, we describe a CAD evaluation methodology based on a publically available, annotated computed tomography (CT) image data set, and demonstrate the evaluation of a new CAD system with the functionality and performance required for adoption in clinical practice. Methods A new automated lung nodule detection and measurement system was developed that incorporates intensity thresholding, a Euclidean Distance Transformation, and segmentation based on watersheds. System performance was evaluated against the Lung Imaging Database Consortium (LIDC) CT reference data set. Results The test set comprised thin-section CT scans from 108 LIDC subjects. The median (+/- IQR) sensitivity per subject was 100 (+/- 37.5) for nodules >= 4 mm and 100 (+/- 8.33) for nodules >= 8 mm. The corresponding false positive rates were 0 (+/- 2.0) and 0 (+/- 1.0), respectively. The concordance correlation coefficient between the CAD nodule diameter and the LIDC reference was 0.91, and for volume it was 0.90. Conclusions The new CAD system shows high nodule sensitivity with a low false positive rate. Automated volume measurements have strong agreement with the reference standard. Thus, it provides comprehensive, clinically-usable lung nodule detection and assessment functionality.
引用
收藏
页码:2719 / 2728
页数:10
相关论文
共 50 条
  • [31] Lung Cancer Screening With Low Dose Computed Tomography in Patients With and Without Prior History of Cancer in the National Lung Screening Trial
    Henderson, Louise M.
    Durham, Danielle D.
    Tammemagi, Martin C.
    Bene, Thad
    Marsh, Mary W.
    Rivera, Patricia
    JOURNAL OF THORACIC ONCOLOGY, 2021, 16 (06) : 980 - 989
  • [32] The budget impact of lung cancer screening with low-dose computed tomography
    Nagy Balazs
    Szilbehorn Laszlo
    Kerpel-Fronius, Anna
    Moizs Mariann
    Bajzik Gabor
    Voko Zoltan
    ORVOSI HETILAP, 2021, 162 (24) : 952 - 959
  • [33] Low-Dose Computed Tomography for Lung Cancer Screening: The Protocol and The Dose
    McDermott, Shaunagh
    Kaira, Mannudeep K.
    SEMINARS IN ROENTGENOLOGY, 2017, 52 (03) : 132 - 136
  • [34] Technical Parameters and Interpretive Issues in Screening Computed Tomography Scans for Lung Cancer
    Donnelly, Edwin F.
    JOURNAL OF THORACIC IMAGING, 2012, 27 (04) : 224 - 229
  • [35] Cost-Effectiveness of Computed Tomography Screening for Lung Cancer in the United States
    McMahon, Pamela M.
    Kong, Chung Yin
    Bouzan, Colleen
    Weinstein, Milton C.
    Cipriano, Lauren E.
    Tramontano, Angela C.
    Johnson, Bruce E.
    Weeks, Jane C.
    Gazelle, G. Scott
    JOURNAL OF THORACIC ONCOLOGY, 2011, 6 (11) : 1841 - 1848
  • [36] Computed Tomography Screening The International Early Lung Cancer Action Program Experience
    Henschke, Claudia I.
    Boffetta, Paolo
    Yankelevitz, David F.
    Altorki, Nasser
    THORACIC SURGERY CLINICS, 2015, 25 (02) : 129 - +
  • [37] The Impact of Computed Tomography Screening for Lung Cancer on Smoking Behaviors A Teachable Moment?
    Poghosyan, Hermine
    Sheldon, Lisa Kennedy
    Cooley, Mary E.
    CANCER NURSING, 2012, 35 (06) : 466 - 475
  • [38] Cost-effectiveness of lung cancer screening with volume computed tomography in Portugal
    ten Berge, Hilde
    Togka, Katerina
    Pan, Xuanqi
    Borges, Marina
    Martelo, Fernando Palma
    Guedes, Fernando
    Cabral, Daniel
    Teixeira, Encarnaco
    Fernandes, Gabriela
    Ferreira, Lurdes
    Figueiredo, Sara
    Sousa, Rita
    Barradas, Lourdes
    Estevinho, Fernanda
    Araujo, Antonio
    Hespanhol, Venceslau
    Medeiros, Rui
    JOURNAL OF COMPARATIVE EFFECTIVENESS RESEARCH, 2024, 13 (11)
  • [39] Nationwide lung cancer screening with low-dose computed tomography: implementation and first results of the HUNCHEST screening program
    Kerpel-Fronius, Anna
    Monostori, Zsuzsanna
    Kovacs, Gabor
    Ostoros, Gyula
    Horvath, Istvan
    Solymosi, Diana
    Pipek, Orsolya
    Szatmari, Ferenc
    Kovacs, Anita
    Markoczy, Zsolt
    Rojko, Livia
    Renyi-Vamos, Ferenc
    Hoetzenecker, Konrad
    Bogos, Krisztina
    Megyesfalvi, Zsolt
    Dome, Balazs
    EUROPEAN RADIOLOGY, 2022, 32 (07) : 4457 - 4467
  • [40] Micronodules Detected on Computed Tomography During the National Lung Screening Trial: Prevalence and Relation to Positive Studies and Lung Cancer
    Munden, Reginald F.
    Chiles, Caroline
    Boiselle, Phillip M.
    Sicks, JoRean D.
    Aberle, Denise R.
    Gatsonis, Constantine A.
    JOURNAL OF THORACIC ONCOLOGY, 2019, 14 (09) : 1538 - 1546