Do indoor pollutants and thermal conditions in schools influence student performance? A critical review of the literature

被引:641
作者
Mendell, MJ
Heath, GA
机构
[1] Univ Calif Berkeley, Lawrence Berkeley Lab, Environm Energy Technol Div, Indoor Environm Dept, Berkeley, CA 94720 USA
[2] Univ Calif Berkeley, Energy & Resources Grp, Berkeley, CA 94720 USA
关键词
indoor environment; indoor air quality; performance; schools; education; children;
D O I
10.1111/j.1600-0668.2004.00320.x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
To assess whether school environments can adversely affect academic performance, we review scientific evidence relating indoor pollutants and thermal conditions, in schools or other indoor environments, to human performance or attendance. We critically review evidence for direct associations between these aspects of indoor environmental quality (IEQ) and performance or attendance. Secondarily, we summarize, without critique, evidence on indirect connections potentially linking IEQ to performance or attendance. Regarding direct associations, little strongly designed research was available. Persuasive evidence links higher indoor concentrations of NO2 to reduced school attendance, and suggestive evidence links low ventilation rates to reduced performance. Regarding indirect associations, many studies link indoor dampness and microbiologic pollutants (primarily in homes) to asthma exacerbations and respiratory infections, which in turn have been related to reduced performance and attendance. Also, much evidence links poor IEQ (e.g. low ventilation rate, excess moisture, or formaldehyde) with adverse health effects in children and adults and documents dampness problems and inadequate ventilation as common in schools. Overall, evidence suggests that poor IEQ in schools is common and adversely influences the performance and attendance of students, primarily through health effects from indoor pollutants. Evidence is available to justify (i) immediate actions to assess and improve IEQ in schools and (ii) focused research to guide IEQ improvements in schools.
引用
收藏
页码:27 / 52
页数:26
相关论文
共 182 条
  • [1] [Anonymous], 1993, INDOOR AIR, DOI DOI 10.1111/J.1600-0668.1993.00005.X
  • [2] [Anonymous], ASHVE T
  • [3] [Anonymous], 1979, Quasi experimental designs and analysesfor issues infield settings
  • [4] [Anonymous], 1993, Journal of Indoor Air, DOI DOI 10.1111/J.1600-0668.1993.T01-1-00002.X
  • [5] APTE MG, 1999, P IND AIR 99 8 INT C, V1, P117
  • [6] Academic achievement in children with epilepsy or asthma
    Austin, JK
    Huberty, TJ
    Huster, GA
    Dunn, DW
    [J]. DEVELOPMENTAL MEDICINE AND CHILD NEUROLOGY, 1998, 40 (04) : 248 - 255
  • [7] Effects of pollution from personal computers on perceived air quality, SBS symptoms and productivity in offices
    Bakó-Biró, Z
    Wargocki, P
    Weschler, CJ
    Fanger, PO
    [J]. INDOOR AIR, 2004, 14 (03) : 178 - 187
  • [8] Bartlett K.H., 1999, IND AIR 99 P 8 INT C, V1, P252
  • [9] BAYER CW, 2000, CAUES INDOOR AIR QUA
  • [10] BUILDING CONDITIONS, PARENTAL INVOLVEMENT, AND STUDENT-ACHIEVEMENT IN THE DISTRICT-OF-COLUMBIA PUBLIC-SCHOOL SYSTEM
    BERNER, MM
    [J]. URBAN EDUCATION, 1993, 28 (01) : 6 - 29