Using 3D Printers to Create Complex Phantoms for Dose Verification, Quality Assurance, and Treatment Planning System Commissioning in Radiotherapy

被引:0
|
作者
Kassaee, A.
Ding, X.
McDonough, J.
Reiche, M.
Witztum, A.
Teo, B.
机构
关键词
Dosimetry; 3D printing; Medical treatment planning; Quality assurance; Photons; Intensity modulated radiation therapy; Protons; Electron beams; Machining;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
WE-F-16A-0
引用
收藏
页码:515 / 515
页数:2
相关论文
共 50 条
  • [21] Adaptation, Commissioning, and Evaluation of a 3D Treatment Planning System for High-Resolution Small-Animal Irradiation
    Jeong, Jeho
    Chen, Qing
    Febo, Robert
    Yang, Jie
    Hai Pham
    Xiong, Jian-Ping
    Zanzonico, Pat B.
    Deasy, Joseph O.
    Humm, John L.
    Mageras, Gig S.
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2016, 15 (03) : 460 - 471
  • [22] Quality assurance for a six degrees-of-freedom table using a 3D printed phantom
    Woods, Kyle
    Ayan, Ahmet S.
    Woollard, Jeffrey
    Gupta, Nilendu
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (01): : 115 - 124
  • [23] Commissioning and validation of fluence-based 3D VMAT dose reconstruction system using new transmission detector
    Nakaguchi Y.
    Oono T.
    Maruyama M.
    Shimohigashi Y.
    Kai Y.
    Nakamura Y.
    Radiological Physics and Technology, 2018, 11 (2) : 165 - 173
  • [24] Experimental verification of a 3D in vivo dose monitoring system based on EPID
    Wang, Xiaoyong
    Chen, Lixin
    Xie, Conghua
    Wang, Dajiang
    Chen, Gaili
    Fu, Zhengming
    Liu, Hui
    ONCOTARGET, 2017, 8 (65) : 109619 - 109631
  • [25] Design, construction, and dosimetry of 3D printed heterogeneous phantoms for synchrotron brain cancer radiation therapy quality assurance
    Bustillo, John Paul O.
    Paino, Jason
    Barnes, Micah
    Cayley, James
    de Rover, Vincent
    Cameron, Matthew
    Engels, Elette E. M.
    Tehei, Moeava
    Beirne, Stephen
    Wallace, Gordon G.
    Rosenfeld, Anatoly B.
    Lerch, Michael L. F.
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (14)
  • [26] Commissioning of motorized wedge for the first Equinox-80 telecobalt unit and implementation in the eclipse 3D treatment planning system
    Kinhikar, R. A.
    Sharma, S.
    Upreti, R.
    Tambe, C. M.
    Deshpande, D. D.
    Shrivastava, S. K.
    Dinshaw, K. A.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2007, 30 (02) : 127 - 134
  • [27] Commissioning of motorized wedge for the first Equinox-80 telecobalt unit and implementation in the Eclipse 3D treatment planning system
    R. A. Kinhikar
    S. Sharma
    R. Upreti
    C. M. Tambe
    D. D. Deshpande
    S. K. Shrivastava
    K. A. Dinshaw
    Australasian Physics & Engineering Sciences in Medicine, 2007, 30 : 127 - 134
  • [28] The use of radiochromic EBT2 film for the quality assurance and dosimetric verification of 3D conformal radiotherapy using Microtek ScanMaker 9800XL flatbed scanner
    Sim, G. S.
    Wong, J. H. D.
    Ng, K. H.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (04): : 85 - 95
  • [29] Determining tolerance levels for quality assurance of 3D printed bolus for modulated arc radiotherapy of the nose
    Kairn, T.
    Talkhani, S.
    Charles, P. H.
    Chua, B.
    Lin, C. Y.
    Livingstone, A. G.
    Maxwell, S. K.
    Poroa, T.
    Simpson-Page, E.
    Spelleken, E.
    Vo, M.
    Crowe, S. B.
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2021, 44 (04) : 1187 - 1199
  • [30] Determining tolerance levels for quality assurance of 3D printed bolus for modulated arc radiotherapy of the nose
    T. Kairn
    S. Talkhani
    P. H. Charles
    B. Chua
    C. Y. Lin
    A. G. Livingstone
    S. K. Maxwell
    T. Poroa
    E. Simpson-Page
    E. Spelleken
    M. Vo
    S. B. Crowe