Using 3D Printers to Create Complex Phantoms for Dose Verification, Quality Assurance, and Treatment Planning System Commissioning in Radiotherapy

被引:0
|
作者
Kassaee, A.
Ding, X.
McDonough, J.
Reiche, M.
Witztum, A.
Teo, B.
机构
关键词
Dosimetry; 3D printing; Medical treatment planning; Quality assurance; Photons; Intensity modulated radiation therapy; Protons; Electron beams; Machining;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
WE-F-16A-0
引用
收藏
页码:515 / 515
页数:2
相关论文
共 50 条
  • [11] 3D CT-based high-dose-rate breast brachytherapy implants: Treatment planning and quality assurance
    Das, RK
    Patel, R
    Shah, H
    Odau, H
    Kuske, RR
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (04): : 1224 - 1228
  • [12] IMRT QUALITY ASSURANCE USING A SECOND TREATMENT PLANNING SYSTEM
    Anjum, Muhammad Naeem
    Parker, William
    Ruo, Russell
    Aldahlawi, Ismail
    Afzal, Muhammad
    MEDICAL DOSIMETRY, 2010, 35 (04) : 274 - 279
  • [13] Low cost multifunctional 3D printed image quality and dose verification phantom for an image-guided radiotherapy system
    Wu, Jian-Kuen
    Yu, Min-Chin
    Chen, Shih-Han
    Liao, Shu-Hsien
    Wang, Yu-Jen
    PLOS ONE, 2022, 17 (04):
  • [14] Error detection using EPID-based 3D in vivo dose verification for lung stereotactic body radiotherapy
    Huang, Jianghua
    Hu, Jinyan
    Lu, Huanping
    Liu, Shijie
    Gong, Fengying
    Wu, Xiuxiu
    Liu, Yimin
    Shi, Juntian
    APPLIED RADIATION AND ISOTOPES, 2023, 192
  • [15] Application of a 3D volumetric display for radiation therapy treatment planning I: quality assurance procedures
    Gong, Xing
    Kirk, Mike
    Zusag, Tom
    Khelashvili, Gocha
    Chu, James
    Napoli, Josh
    Stutsman, Sandy
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2009, 10 (03): : 96 - 114
  • [16] Verification of Acuros XB dose algorithm using 3D printed low-density phantoms for clinical photon beams
    Zavan, Rodolfo
    McGeachy, Philip
    Madamesila, Joseph
    Villarreal-Barajas, Jose-Eduardo
    Khan, Rao
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (03): : 32 - 43
  • [17] Development of a 3D printed phantom for commissioning and quality assurance of multiple brain targets stereotactic radiosurgery
    Mukwada, Godfrey
    Hirst, Andrew
    Rowshanfarzad, Pejman
    Ebert, Martin A.
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2024, 47 (02) : 455 - 463
  • [18] Preclinical dose verification using a 3D printed mouse phantom for radiobiology experiments
    Esplen, Nolan
    Therriault-Proulx, Francois
    Beaulieu, Luc
    Bazalova-Carter, Magdalena
    MEDICAL PHYSICS, 2019, 46 (11) : 5294 - 5303
  • [19] Density scaling of phantom materials for a 3D dose verification system
    Tani, Kensuke
    Fujita, Yukio
    Wakita, Akihisa
    Miyasaka, Ryohei
    Uehara, Ryuzo
    Kodama, Takumi
    Suzuki, Yuya
    Aikawa, Ako
    Mizuno, Norifumi
    Kawamori, Jiro
    Saitoh, Hidetoshi
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (04): : 103 - 113
  • [20] Efficient and reliable 3D dose quality assurance for IMRT by combining independent dose calculations with measurements
    Visser, R.
    Wauben, D. J. L.
    de Groot, M.
    Godart, J.
    Langendijk, J. A.
    van't Veld, A. A.
    Korevaar, E. W.
    MEDICAL PHYSICS, 2013, 40 (02)