Modulation; Medical services; Medical diagnostic imaging; Power demand; Bandwidth; Sigma-delta modulation; Voltage; Analog-digital conversion; sigma-delta A; D converters; medical diagnostic; healthcare devices; switched-capacitor circuits; low-voltage; low-power; operational amplifiers; SWITCHED-CAPACITOR; LOW-VOLTAGE; DESIGN; AMPLIFIER; CMOS; ADC;
D O I
10.1109/TCSI.2021.3112342
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a switched-capacitor Sigma-Delta modulator designed in 90-nm CMOS technology, operating at 1.2-V supply voltage. The modulator targets healthcare and medical diagnostic applications where the readout of small-bandwidth signals is required. The design of the proposed A/D converter was optimized to achieve the minimum power consumption and area. A remarkable performance improvement is obtained through the integration of a low-noise amplifier with modified Miller compensation and rail-to-rail output stage. The manuscript also presents a set of design equations, from the small-signal analysis of the amplifier, for an easy design of the modulator in different technology nodes. The Sigma-Delta converter achieves a measured 96-dB dynamic range, over a 250-Hz signal bandwidth, with an oversampling ratio of 500. The power consumption is 30 mu W, with a silicon area of 0.39 mm(2).
引用
收藏
页码:207 / 219
页数:13
相关论文
共 53 条
[1]   AN IMPROVED FREQUENCY COMPENSATION TECHNIQUE FOR CMOS OPERATIONAL-AMPLIFIERS [J].
AHUJA, BK .
IEEE JOURNAL OF SOLID-STATE CIRCUITS, 1983, 18 (06) :629-633
[2]   pyPhotometry: Open source Python']Python based hardware and software for fiber photometry data acquisition [J].
Akam, Thomas ;
Walton, Mark E. .
SCIENTIFIC REPORTS, 2019, 9 (1)
[3]  
Analog Devices, 2021, LIF SCI MED INTR
[4]  
[Anonymous], 2012, P ESSCIRC ESSCIRC SE
[5]  
[Anonymous], 2011, P EUR SOL STAT CIRC
[6]  
[Anonymous], 2005, Understanding Delta-Sigma Data Converters
[7]   Use of Lying Drop Photometry for Clinical Laboratory Diagnostics [J].
Aristov A.A. ;
Nosova E.V. ;
Soldatov A.N. .
Biomedical Engineering, 2017, 50 (05) :314-317
[8]   Linearity enhancement of multibit Delta Sigma and D/A converters using data weighted averaging [J].
Baird, RT ;
Fiez, TS .
IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS II-ANALOG AND DIGITAL SIGNAL PROCESSING, 1995, 42 (12) :753-762
[9]   A Wi-Fi Cloud-Based Portable Potentiostat for Electrochemical Biosensors [J].
Bianchi, Valentina ;
Boni, Andrea ;
Fortunati, Simone ;
Giannetto, Marco ;
Careri, Maria ;
De Munari, Ilaria .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2020, 69 (06) :3232-3240
[10]   A Self-Calibrating IoT Portable Electrochemical Immunosensor for Serum Human Epididymis Protein 4 as a Tumor Biomarker for Ovarian Cancer [J].
Bianchi, Valentina ;
Mattarozzi, Monica ;
Giannetto, Marco ;
Boni, Andrea ;
De Munari, Ilaria ;
Careri, Maria .
SENSORS, 2020, 20 (07)