Shaping ability of Mity Roto 360° and Naviflex rotary nickel-titanium instruments in simulated root canals.: Part 1

被引:8
|
作者
Thompson, SA [1 ]
Dummer, PMH [1 ]
机构
[1] Univ Wales Coll Med, Sch Dent, Dept Restorat Dent, Cardiff CF4 4XY, S Glam, Wales
关键词
D O I
10.1016/S0099-2399(98)80093-9
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of this study was to determine the shaping ability of Mity Roto 360 degrees and Naviflex nickel-titanium rotary instruments in simulated root canals. In all, 80 canals consisting of four different shapes in terms of angle and position of curvature were prepared by Mity Roto 360 degrees and Naviflex instruments using the techniques recommended by the manufacturers. This study describes the efficacy of the instruments in terms of preparation time, instrument failure, canal blockages, change in canal length, and three-dimensional canal form. Overall, the mean preparation time for canals prepared using Mity instruments was 5.99 min and 5.81 min when using Naviflex instruments. Canal shape had no significant effect on the speed of preparation with either instrument. No instruments separated during the study; however, 14 Naviflex and 2 Mity instruments were deformed. Canal type did not influence significantly the tendency of either instrument to deform. None of the canals became blocked with debris during preparation. The majority of canals prepared by both instruments retained their original working length, and there was no significant difference between the canal shapes in terms of the mean loss of distance or category of distance change for either instrument. Apical stops as judged from intracanal impressions were present in 29 (72%) of the canals prepared with Mity instruments and in 33 (82%) of those prepared with Naviflex instruments. However, the majority were judged to be of poor quality. Significant differences (p < 0.05) were noted in the quality of apical stops between the canal types using Mity instruments. Canals prepared with Mity and Naviflex instruments were found to be smooth in the apical half of the canal in approximately one-half of the specimens and coronally in nearly all canals. Neither instrument produced horizontal or longitudinal grooves. Favorable flow characteristics were apparent in over one-half of the canals prepared with Mity Roto instruments; however, nearly all specimens had poor taper. Flow and taper were generally poor in the specimens prepared with Naviflex instruments. Under the conditions of this study, Mity Roto 360 degrees and Naviflex instruments prepared canals rapidly, with no separations, canal blockages, and with minimal change in working length. Although, flow was adequate using Mity Roto 360 degrees instruments, the taper characteristics were less than ideal compromising the three-dimensional form of the canals. Naviflex instruments, while creating better taper, produced poorer flow characteristics. The results suggest that when using Mity Roto 360 degrees or Naviflex instruments, the stepdown sequence should be modified to improve canal flow and taper. Alternatively, an instrument with increased taper should be used to complete preparation before obturation.
引用
收藏
页码:128 / 134
页数:7
相关论文
共 50 条
  • [31] Efficiency of rotary nickel-titanium K3 instruments compared with stainless steel hand K-Flexofile.: Part 1.: Shaping ability in simulated curved canals
    Schäfer, E
    Florek, H
    INTERNATIONAL ENDODONTIC JOURNAL, 2003, 36 (03) : 199 - 207
  • [32] Shaping Ability of Three Nickel-Titanium Endodontic File Systems in Simulated S-shaped Root Canals
    Burroughs, Jeffrey R.
    Bergeron, Brian E.
    Roberts, Mark D.
    Hagan, Joseph L.
    Himel, Van T.
    JOURNAL OF ENDODONTICS, 2012, 38 (12) : 1618 - 1621
  • [33] Comparison of the shaping ability of GT® Series X, Twisted Files and AlphaKite rotary nickel-titanium systems in simulated canals
    Raidan Ba-Hattab
    Anne-Kathrin Pröhl
    Hermann Lang
    Dieter Pahncke
    BMC Oral Health, 13
  • [34] Evaluation of the root canal shaping ability of two rotary nickel-titanium systems
    Al-Manei, K. K.
    Al-Hadlaq, S. M. S.
    INTERNATIONAL ENDODONTIC JOURNAL, 2014, 47 (10) : 974 - 979
  • [35] Comparison of the shaping ability of GT® Series X, Twisted Files and AlphaKite rotary nickel-titanium systems in simulated canals
    Ba-Hattab, Raidan
    Proehl, Anne-Kathrin
    Lang, Hermann
    Pahncke, Dieter
    BMC ORAL HEALTH, 2013, 13
  • [36] The influence of various automated devices on the shaping ability of Mtwo rotary nickel-titanium instruments
    Buerklein, S.
    Schaefer, E.
    INTERNATIONAL ENDODONTIC JOURNAL, 2006, 39 (12) : 945 - 951
  • [37] Cyclic fatigue behavior of nickel-titanium dental rotary files in clinical simulated root canals
    Chi, Chih-Wen
    Li, Chun-Chieh
    Lin, Chun-Pin
    Shin, Chow-Shing
    JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 2017, 116 (04) : 306 - 312
  • [38] A comparison of instrumentation using Naviflex and Profile nickel-titanium engine-driven rotary instruments
    Ottosen, SR
    Nicholls, JI
    Steiner, JC
    JOURNAL OF ENDODONTICS, 1999, 25 (06) : 457 - 460
  • [39] Shaping ability of five different nickel-titanium systems in simulated S-shaped canals
    Koring, Stella
    Schwahn, Christian
    Kocher, Thomas
    Steffen, Heike
    ENDO-ENDODONTIC PRACTICE TODAY, 2020, 14 (02): : 135 - 143
  • [40] The study of the shaping ability of three nickel-titanium rotary instruments to two apical dimensions.
    Wei, X
    Ling, JQ
    Cheung, GSP
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : 334 - 334