A Distribution Line Model for Lightning Overvoltage Studies

被引:3
|
作者
Matsuura, Susumu
Noda, Taku
Asakawa, Akira
Yokoyama, Shigeru
机构
[1] Electric Power Engineering Research Laboratory, CRIEPI
关键词
distribution line; direct lightning stroke; lightning overvoltage; EMTP; modeling; SURGE RESPONSE; STROKES;
D O I
10.1002/eej.21001
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Recently, the focus of lightning protection measures for distribution lines has moved from a nearby lightning stroke to a direct lightning stroke. Studies of direct lightning stroke countermeasures are generally carried out by digital simulations using the EMTP (Electro-Magnetic Transients Program). Thus, components of a distribution line must be modeled appropriately in the EMTP for accurate simulations. The authors have previously clarified the surge response of a distribution line by pulse tests using a reduced-scale distribution line model. In this paper, first, the results of the pulse tests are simulated in the EMTP using a conventional model which represents a distribution pole by a single lossless distributed-parameter line model, and comparisons with the test results show that transient overvoltages generated at the insulators cannot accurately be reproduced by the conventional model. This indicates that a special treatment is required to represent the transient response of a distribution pole and wires. Then, this paper proposes new EMTP models of the pole and wires which can reproduce the transient overvoltages at the insulators. The parameter values of the proposed models can be determined based on a pulse test result. 2010 Wiley Periodicals, Inc. Electr Eng Jpn, 173(1): 11-23, 2010; Published online in Wiley InterScience (www.interscience.wiley.com). DOI 10.1002/eej.21001
引用
收藏
页码:11 / 23
页数:13
相关论文
共 50 条
  • [31] Lightning surge analysis model of reinforced concret pole and grounding lead conductor in distribution line
    Sekioka, Show
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2008, 3 (04) : 432 - 440
  • [32] Overvoltage's expose of HV substacion by lightning stroke and back-flashover
    Mackiewicz, Marcin Maciej
    PRZEGLAD ELEKTROTECHNICZNY, 2010, 86 (11B): : 94 - 96
  • [33] Lightning Fault Rate of Power Distribution Line in Wind Farm in Winter Lightning Area
    Michishita, Koji
    Yokoyama, Shigeru
    PROCEEDINGS OF THE 21ST INTERNATIONAL SYMPOSIUM ON HIGH VOLTAGE ENGINEERING, VOL 1, 2020, 598 : 1377 - 1389
  • [34] Evaluation of lightning overvoltage at neutral point of HVDC converter transformer based on EMTP
    Hu, Zhe
    Han, Yang
    Yang, Ping
    Wang, Conling
    Zalhaf, Amr S.
    ENERGY REPORTS, 2022, 8 : 274 - 283
  • [35] CALCULATION ESTIMATION OF OVERVOLTAGE ON INSULATION OF THE EQUIPMENT OF A SUBSTATION AT THE LIGHTNING STRIKE IN ITS LIGHTNING ARRESTER
    Nizhevskyi, I., V
    Nizhevskyi, V., I
    ELECTRICAL ENGINEERING & ELECTROMECHANICS, 2019, (03) : 67 - 73
  • [36] Overvoltage Response at the Terminal for Impulse Current Injection to 10 kV Distribution Line
    Wang, Jianguo
    Xu, Zhiling
    Cai, Li
    Fang, Yuquan
    Lu, Dai
    Huang, Huan
    Zhou, Mi
    Fan, Yadong
    IEEE TRANSACTIONS ON POWER DELIVERY, 2022, 37 (05) : 3722 - 3729
  • [37] A Model of Pole-Mounted Distribution Transformer for Lightning Failure Analysis -A Model Capable of Calculating Lightning Overvoltages in Transformer Windings-
    Kanatani K.
    Matsuura S.
    Fujita H.
    Michishita K.
    IEEJ Transactions on Power and Energy, 2023, 143 (02) : 165 - 175
  • [38] Probability of appearance of certain value of phase to ground overvoltage due to direct lightning stroke
    Skuletic, Sreten
    Vucinic, Aleksandar
    PROCEEDINGS OF THE SIXTH IASTED INTERNATIONAL CONFERENCE ON EUROPEAN POWER AND ENERGY SYSTEMS, 2006, : 119 - +
  • [39] Equivalent Circuit of Distribution Line for Lightning-Induced Voltage Analysis Using Analytical Formulas
    Sekioka, Shozo
    ELECTRICAL ENGINEERING IN JAPAN, 2017, 199 (03) : 26 - 34
  • [40] Equivalent circuit of distribution line for lightning-induced voltage analysis using analytical formulas
    Sekioka S.
    Sekioka, Shozo (sekioka@elec.shonan-it.ac.jp), 1600, Institute of Electrical Engineers of Japan (136): : 610 - 616