A randomized cross-over study with objective quantification of the performance of an asymmetric triacetate and a polysulfone dialysis membrane using different anticoagulation strategies

被引:11
作者
Vanommeslaeghe, Floris [1 ]
Josipovic, Ivan [2 ]
Boone, Matthieu [2 ]
Dhondt, Annemie [1 ]
Van Biesen, Wim [1 ]
Eloot, Sunny [1 ]
机构
[1] Ghent Univ Hosp, Nephrol Dept, Ghent, Belgium
[2] Univ Ghent, Ctr Xray Tomog Phys & Astron, Ghent, Belgium
关键词
anticoagulation; clotting; haemodialysis; micro-CT scan; polymers; REGIONAL CITRATE ANTICOAGULATION; HIGH-FLUX DIALYZERS; HEMODIALYSIS; BIOINCOMPATIBILITY; EXPRESSION; EFFICACY; RISK; SAFE;
D O I
10.1093/ckj/sfz163
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background. Different strategies can be used to counteract coagulation of extracorporeal systems. Systemic anticoagulation is most widely used in routine clinical practice, but can be contraindicated in specific settings. The Solacea((TM)) dialyser, containing the asymmetric triacetate membrane, claims improved biocompatibility, which should result in decreased tendency for coagulation. We quantified the performance of the Solacea (TM) versus the FX800CORDIAX dialyser regarding resistance to fibre blocking as assessed by micro-computed tomography (CT). Methods. This cross-over study with four arms randomized consecutively 10 maintenance haemodialysis patients to a 4-h post-dilution haemodiafiltration session at midweek, using either Solacea (TM) 19H or FX800CORDIAX, with either regular or half dose of anticoagulation (EC2017/1459-NCT03820401). Dialyser fibre blocking was visualized in the dialyser outlet potting using a 3D CT scanning technique on micrometre resolution. Extraction ratios of middle molecules [myoglobin, lambda and kappa free light chains (FLCs)] were determined. Results. The relative number of open fibres post-dialysis was lower in FX800CORDIAX versus Solacea (TM) dialyser, and this was irrespective of the anticoagulation dose used or the threshold for counting open fibres. Extraction ratios of FLCs were not different at regular anticoagulation between Solacea (TM) and FX800CORDIAX (21%4% for kappa and 32%+/- 8% for lambda with Solacea (TM) versus 23%+/- 7% and 38%+/- 6% for FX800CORDIAX), but were superior with the Solacea (TM) (34%+/- 12% versus 22%+/- 8% with FX800CORDIAX; P=0.02) for myoglobin in case of halving anticoagulation dose. No clinically relevant albumin loss was detected. Conclusions. The Solacea (TM) dialyser seems to be promising for use in conditions where systemic anticoagulation is contraindicated, as even under conditions of low systemic anticoagulation, virtually no signs of fibre blocking could be observed using the sensitive micro-CT scanning technique. This finding is in line with its presumed good performance in terms of biocompatibility.
引用
收藏
页码:398 / 407
页数:10
相关论文
共 30 条
[1]  
[Anonymous], 2002, NEPHROL DIAL TRANSPL, V17, P63
[2]   Citrate for long-term hemodialysis: Prospective study of 1,009 consecutive high-flux treatments in 59 patients [J].
Apsner, R ;
Buchmayer, H ;
Gruber, D ;
Sunder-Plassmann, G .
AMERICAN JOURNAL OF KIDNEY DISEASES, 2005, 45 (03) :557-564
[3]  
Bosch T, 1985, Contrib Nephrol, V46, P14
[4]   Effect of different dialysis membranes on platelet function. A tool for biocompatibility evaluation [J].
Desanctis, LB ;
Stefoni, S ;
Cianciolo, G ;
Coli, L ;
Buscaroli, A ;
Feliciangeli, G ;
Borgnino, LC ;
Bonetti, M ;
Gregorini, MC ;
DeGiovanni, P ;
Buttazzi, R .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1996, 19 (07) :404-410
[5]   Citrate anticoagulation does not correct cuprophane bioincompatibility as evaluated by the expression of leukocyte surface molecules [J].
Dhondt, A ;
Vanholder, R ;
Waterloos, MA ;
Glorieux, G ;
De Smet, R ;
Lameire, N .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 1998, 13 (07) :1752-1758
[6]   Effect of regional citrate anticoagulation on leukopenia, complement activation, and expression of leukocyte surface molecules during hemodialysis with unmodified cellulose membranes [J].
Dhondt, A ;
Vanholder, R ;
Tielemans, C ;
Glorieux, G ;
Waterloos, MA ;
De Smet, R ;
Lameire, N .
NEPHRON, 2000, 85 (04) :334-342
[7]   Heparin-coated polyacrylonitrile membrane versus regional citrate anticoagulation: A prospective randomized study of 2 anticoagulation strategies in patients at risk of bleeding [J].
Evenepoel, Pieter ;
Dejagere, Tom ;
Verhamme, Peter ;
Claes, Kathleen ;
Kuypers, Dirk ;
Bammens, Bert ;
Vanrenterghem, Yves .
AMERICAN JOURNAL OF KIDNEY DISEASES, 2007, 49 (05) :642-649
[8]   Avoidance of systemic anticoagulation during intermittent haemodialysis with heparin-grafted polyacrilonitrile membrane and citrate-enriched dialysate: a retrospective cohort study [J].
Francois, Karlien ;
Wissing, Karl Martin ;
Jacobs, Rita ;
Boone, Dries ;
Jacobs, Kristine ;
Tielemans, Christian .
BMC NEPHROLOGY, 2014, 15
[9]   Evaluation of the efficacy of a medium cut-off dialyser and comparison with other high-flux dialysers in conventional haemodialysis and online haemodiafiltration [J].
Garcia-Prieto, Ana ;
Vega, Almudena ;
Linares, Tania ;
Abad, Soraya ;
Macias, Nicolas ;
Aragoncillo, Ines ;
Torres, Esther ;
Hernandez, Andres ;
Barbieri, Diego ;
Luno, Jose .
CLINICAL KIDNEY JOURNAL, 2018, 11 (05) :742-746
[10]   Long-Term Citrate Anticoagulation in Chronic Hemodialysis Patients [J].
Gubensek, Jakob ;
Kovac, Janko ;
Benedik, Miha ;
Marn-Pernat, Andreja ;
Knap, Bojan ;
Ponikvar, Rafael ;
Buturovic-Ponikvar, Jadranka .
THERAPEUTIC APHERESIS AND DIALYSIS, 2011, 15 (03) :278-282