Evaluation of Dose Calculation of RayStation Planning System in Heterogeneous Media

被引:0
作者
Xu, H. [1 ]
Yi, B. [1 ]
Chung, H. [1 ]
Prado, K. [1 ]
Chen, S. [1 ]
机构
[1] Univ Maryland, Sch Med, Baltimore, MD 21201 USA
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
SU-E-T-162
引用
收藏
页码:259 / 260
页数:2
相关论文
共 50 条
[41]   Comparison of five dose calculation algorithms in a heterogeneous media using design of experiment [J].
Vangvichith, M. ;
Autret, D. ;
Tiplica, T. ;
Barreau, M. ;
Dufreneix, S. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 61 :103-111
[42]   Photon dose calculation analysis of a varian treatment planning system algorithm on a siemens linear accelerator in inhomogeneous media [J].
Finlay, J. ;
Mesina, C. .
MEDICAL PHYSICS, 2007, 34 (06) :2481-2481
[43]   Raystation KV cone-beam CT radiotherapy dose calculation: toward clinical dose tracking [J].
Snir, Jonatan ;
Murrell, Donna ;
Fakir, Hatim .
MEDICAL PHYSICS, 2017, 44 (08) :4380-4380
[44]   Evaluation of RayStation?s delivered dose and accumulated dose features for spine stereotactic radiotherapy [J].
Vaccarelli, Marissa Joyce ;
Krafft, Shane Paul ;
Briere, Tina Marie ;
Svensson, Stina ;
Han, Eun Young .
MEDICAL DOSIMETRY, 2023, 48 (01) :1-7
[45]   A protocol to assess the dose calculation features of a treatment planning system [J].
Senchea, GL ;
Panitsa, E ;
Theodorou, K ;
Rosenwald, JC ;
Kappas, C .
BALKAN CONGRESS OF ONCOLOGY, 1996, :135-141
[46]   Verification of Buildup Region Dose Calculation of a Treatment Planning System [J].
Bassey, B. ;
Sidhu, N. .
MEDICAL PHYSICS, 2012, 39 (07) :4635-4635
[47]   A BrachyPhantom for verification of dose calculation of HDR brachytherapy planning system [J].
Austerlitz, C. ;
Campos, C. A. T. .
MEDICAL PHYSICS, 2013, 40 (11)
[48]   A SYSTEM OF DOSE CALCULATION AND TREATMENT PLANNING USING INDEPENDENT JAW [J].
KHAN, FM ;
GERBI, BJ ;
DEIBEL, FC .
MEDICAL PHYSICS, 1985, 12 (04) :508-508
[49]   Validation of the Usefulness of Dose Calculation Algorithms in Radiotherapy Planning System [J].
Kieltyka, B. ;
Rawojc, K. ;
Kisielewicz, K. ;
Markiewicz, I. .
ACTA PHYSICA POLONICA A, 2016, 129 (02) :219-221
[50]   Using of PL-estimator of a dose at a point for dose calculation in heterogeneous media by Monte Carlo method [J].
Chupikin, D. A. ;
Donskoy, E. N. ;
Jourov, Y. V. ;
Klimanov, V. A. ;
Kosterev, V. V. ;
Smirnov, V. V. .
WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 :2072-+