Evaluation of Dose Calculation of RayStation Planning System in Heterogeneous Media

被引:0
作者
Xu, H. [1 ]
Yi, B. [1 ]
Chung, H. [1 ]
Prado, K. [1 ]
Chen, S. [1 ]
机构
[1] Univ Maryland, Sch Med, Baltimore, MD 21201 USA
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
SU-E-T-162
引用
收藏
页码:259 / 260
页数:2
相关论文
共 50 条
  • [21] Evaluation of Heterogeneity Corrections Made by RayStation Treatment Planning
    Rodriguez, M.
    Bartolac, S.
    Rezaee, M.
    Bissonnette, J.
    MEDICAL PHYSICS, 2015, 42 (06) : 3423 - 3423
  • [22] Validation of RayStation Monte Carlo dose calculation algorithm for multiple LINACs
    Manco, Luigi
    Vega, Kevin
    Maffei, Nicola
    Gutierrez, Maria Victoria
    Cenacchi, Elisa
    Bernabei, Annalisa
    Bruni, Alessio
    D'angelo, Elisa
    Meduri, Bruno
    Lohr, Frank
    Guidi, Gabriele
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2023, 109
  • [23] Modeling of couch transmission in the RayStation treatment planning system
    Savini, Alessandro
    Bartolucci, Floriana
    Fidanza, Christian
    Rosica, Federica
    Orlandi, Giovanni
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (05): : 735 - 740
  • [24] Accuracy evaluation of dose calculation of ISOgray treatment planning system in wedged treatment fields
    Raghavi, S.
    Sadoughi, H. R.
    Ravari, M. E.
    Mansoury, M. A. Tajik
    Behmadi, M.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2020, 22 (02): : 303 - 308
  • [25] Evaluation of the usefulness of dose calculation algorithms in radiotherapy planning
    Kieltyka, B.
    Rawojc, K.
    Kisielewicz, K.
    Markiewicz, I.
    RADIOTHERAPY AND ONCOLOGY, 2016, 118 : S88 - S89
  • [26] Comparison of the RayStation photon Monte Carlo dose calculation algorithm against measured data under homogeneous and heterogeneous irradiation geometries
    Richmond, Neil
    Angerud, Agnes
    Tamm, Fredrik
    Allen, Vincent
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 82 : 87 - 99
  • [27] Dose distribution evaluation of various dose calculation algorithms in inhomogeneous media
    Kim, Y. L.
    Suh, T. S.
    Choe, B. Y.
    Choi, B. O.
    Chung, J. B.
    Lee, J. W.
    Bae, Y. K.
    Park, B. M.
    Jung, J. Y.
    Shin, Y. J.
    Kim, J. Y.
    Moon, S. K.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2016, 14 (04): : 269 - 278
  • [28] An evaluation of the use of DirectSPR images for proton planning in the RayStation treatment planning software
    Sarkar, Vikren
    Paxton, Adam
    Su, Fanchi
    Price, Ryan
    Nelson, Geoff
    Szegedi, Martin
    St James, Sara
    Salter, Bill J.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (05):
  • [29] Evaluation of Out-of-Field Dose Calculation Accuracy of CyberKnife. System in Heterogeneous Phantom
    Yoon, J.
    Sharma, S.
    Feng, Y.
    MEDICAL PHYSICS, 2018, 45 (06) : E591 - E591
  • [30] IQM system: preliminary tests and implementation on Raystation treatment planning system
    Haller, M.
    Ferrari, P.
    Hofer, S.
    Maffei, M.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2016, 192 : 84 - 84