Image Guidance for All-TilePro Display of 3-Dimensionally Reconstructed Images in Robotic Partial Nephrectomy REPLY

被引:1
作者
Hughes-Hallett, Archie [1 ]
Pratt, Philip [2 ]
Mayer, Erik [1 ]
Martin, Shirley [3 ]
Darzi, Ara [1 ,2 ]
Vale, Justin [1 ]
机构
[1] Imperial Coll London, Dept Surg & Canc, London, England
[2] Imperial Coll London, Hamlyn Ctr Robot Surg, London, England
[3] Imperial Coll Hlthcare NHS Trust, London, England
关键词
WARM-UP;
D O I
10.1016/j.urology.2014.02.059
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE To determine the feasibility of a novel low-barrier-to-entry image guidance system. METHODS Initially a randomized crossover study was performed to establish the interface (iPad or 3-dimensional mouse) that minimized both the amount of time required to perform a manual image registration and the error of that registration. A subsequent clinical feasibility study was undertaken on 5 patients undergoing robot-assisted partial nephrectomy. Randomized crossover study primary outcomes were time to task completion, NASA-Task Load Index score, and alignment error (translational and rotational). The Mann-Whitney U test was used to compare groups. Surgeon feedback was sought when assessing the system in a clinical setting. RESULTS In the initial randomized crossover study, the iPad-based system was able to achieve adequate alignment accuracy (Frobenius norm of 0.3; total error of 20.8 mm) in significantly less time (33 seconds; P <.01) than the 3-dimensional mouse interface. The platform received good feedback from the operating surgeon in all instances with the surgeon commenting particularly on the improved appreciation of hilar vascular anatomy. CONCLUSION In this study, we have demonstrated the feasibility of a "low-barrier-to-entry" image guidance system in a clinical setting. The system was able to achieve swift and sufficiently accurate alignment, with little impact on the surgical workflow. (C) 2014 Elsevier Inc.
引用
收藏
页码:243 / 243
页数:1
相关论文
共 6 条
[1]   Warm-up in a Virtual Reality Environment Improves Performance in the Operating Room [J].
Calatayud, Dan ;
Arora, Sonal ;
Aggarwal, Rajesh ;
Kruglikova, Irina ;
Schulze, Svend ;
Funch-Jensen, Peter ;
Grantcharov, Teodor .
ANNALS OF SURGERY, 2010, 251 (06) :1181-1185
[2]   Segmentations of MRI Images of the Female Pelvic Floor: A Study of Inter- and Intra-reader Reliability [J].
Hoyte, Lennox ;
Ye, Wen ;
Brubaker, Linda ;
Fielding, Julia R. ;
Lockhart, Mark E. ;
Heilbrun, Marta E. ;
Brown, Morton B. ;
Warfield, Simon K. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 33 (03) :684-691
[3]  
Hughes-Hallett A, UROLOGY, DOI [10.1016/j.urology.2014.03.033, DOI 10.1016/J.UROLOGY.2014.03.033]
[4]   Augmented Reality Partial Nephrectomy: Examining the Current Status and Future Perspectives [J].
Hughes-Hallett, Archie ;
Mayer, Erik K. ;
Marcus, Hani J. ;
Cundy, Thomas P. ;
Pratt, Philip J. ;
Darzi, Ara W. ;
Vale, Justin A. .
UROLOGY, 2014, 83 (02) :266-273
[5]   Virtual Surgical Planning: A Novel Aid to Robot-Assisted Laparoscopic Partial Nephrectomy [J].
Lasser, Michael S. ;
Doscher, Matthew ;
Keehn, Aryeh ;
Chernyak, Victoria ;
Garfein, Evan ;
Ghavamian, Reza .
JOURNAL OF ENDOUROLOGY, 2012, 26 (10) :1372-1379
[6]   Simulated Procedure Rehearsal Is More Effective Than a Preoperative Generic Warm-Up for Endovascular Procedures [J].
Willaert, Willem I. M. ;
Aggarwal, Rajesh ;
Daruwalla, Farhad ;
van Herzeele, Isabelle ;
Darzi, Ara W. ;
Vermassen, Frank E. ;
Cheshire, Nicholas J. .
ANNALS OF SURGERY, 2012, 255 (06) :1184-1189