Pantograph Arcing in Electrified Railways-Mechanism and Influence of Various Parameters-Part I: With DC Traction Power Supply

被引:74
作者
Midya, Surajit [1 ]
Bormann, Dierk [2 ]
Schuette, Thorsten [3 ]
Thottappillil, Rajeev [4 ]
机构
[1] Bombardier Transportat, Rail Control Solut, S-11760 Stockholm, Sweden
[2] ABB Corp Res, Dept Power Technol, S-72130 Vasteras, Sweden
[3] Rejlers Ingenjorer AB, S-72130 Vasteras, Sweden
[4] Royal Inst Technol, S-10044 Stockholm, Sweden
关键词
Arc discharges; electromagnetic compatibility (EMC); electromagnetic interference (EMI); rail transportation; rail-transportation power systems;
D O I
10.1109/TPWRD.2009.2021035
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Pantograph arcing is a common phenomenon in electrified railway systems. This is also a source of broadband-conducted and radiated electromagnetic interference (EMI) for vehicle as well as traction power and signaling systems. In this paper and the companion paper, experimental analyses of pantograph arcing phenomena are presented for dc and ac feeding systems, respectively. Influences of different parameters on dc traction system, such as supply-voltage polarity, relative motion between pantograph and overhead contact wire, namely, forward motion along the track (longitudinal), and lateral sliding motion of the pantograph (zigzag) are presented here. From the voltage and current waveforms of the test runs, it is shown that pantograph arcing is a polarity-dependent phenomenon. For the positive-fed overhead traction system, where pantograph is cathode, the supply interruptions due to zigzag motion are comparatively less compared to negatively fed traction systems. As a result, the transients, due to pantograph arcing, are more frequent in negatively fed traction systems. It is found that the arc root movement along the electrode surfaces (pantograph-contact wire) is governed by the relative motion and polarity of the electrodes. The analyses presented in this paper also form a foundation to understand the pantograph arcing process and the corresponding influential parameters with the ac supply presented in the companion paper. The findings presented in this paper could be beneficial for coming up with appropriate mitigation techniques from the EMI due to pantograph arcing in dc-fed traction systems.
引用
收藏
页码:1931 / 1939
页数:9
相关论文
共 26 条
[1]  
[Anonymous], 1946, Electrical Contacts
[2]  
[Anonymous], P 11 IMEKO TC 4 S TR
[3]  
BERGER T, 2005, ICING OVERHEADLINES
[4]  
BOARD E, 2008, ELECT BAHNEN, V106, P97
[5]  
BORMANN D, 2003, SECRCPTTR2003038
[6]  
Bormann D, 2007, EMC ZURICH-MUNICH 2007, SYMPOSIUM DIGEST, P369
[7]   Influence of electric fields on the tribological behaviour of electrodynamical copper/steel contacts [J].
Bouchoucha, A ;
Zaidi, H ;
Kadiri, EK ;
Paulmier, D .
WEAR, 1997, 203 :434-441
[8]  
BOUCHOUCHA A, 1995, P 22 INT C MET COA 2, P521
[9]  
BRILLANTE S, 1998, P INT C COMP AID DES, P881
[10]  
BUHRKALL L, 2005, ELECT BAHNEN, V103, P380