Detection of low-volume blood loss: Compensatory reserve versus traditional vital signs

被引:59
作者
Tisherman, Samuel A. [1 ]
机构
[1] Univ Maryland, Sch Med, R Adams Cowley Shock Trauma Ctr, Baltimore, MD 21201 USA
关键词
D O I
10.1097/TA.0000000000000423
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BACKGROUND: Humans are able to compensate for low-volume blood loss with minimal change in traditional vital signs. We hypothesized that a novel algorithm, which analyzes photoplethysmogram (PPG) wave forms to continuously estimate compensatory reserve would provide greater sensitivity and specificity to detect low-volume blood loss compared with traditional vital signs. The compensatory reserve index (CRI) is a measure of the reserve remaining to compensate for reduced central blood volume, where a CRI of 1 represents supine normovolemia and 0 represents the circulating blood volume at which hemodynamic decompensation occurs; values between 1 and 0 indicate the proportion of reserve remaining. METHODS: Subjects underwent voluntary donation of 1 U (approximately 450 mL) of blood. Demographic and continuous noninvasive vital sign wave form data were collected, including PPG, heart rate, systolic blood pressure, cardiac output, and stroke volume. PPG wave forms were later processed by the algorithm to estimate CRI values. RESULTS: Data were collected from 244 healthy subjects (79 males and 165 females), with a mean (SD) age of 40.1 (14.2) years and mean (SD) body mass index of 25.6 (4.7). After blood donation, CRI significantly decreased in 92% (alpha = 0.05; 95% confidence interval [CI], 88-95%) of the subjects. With the use of a threshold decrease in CRI of 0.05 or greater for the detection of 1 U of blood loss, the receiver operating characteristic area under the curve was 0.90, with a sensitivity of 0.84 and specificity of 0.86. In comparison, systolic blood pressure (52%; 95% CI, 45-59%), heart rate (65%; 95% CI, 58-72%), cardiac output (47%; 95% CI, 40-54%), and stroke volume (74%; 95% CI, 67-80%) changed in fewer subjects, had significantly lower receiver operating characteristic area under the curve values, and significantly lower specificities for detecting the same volume of blood loss. CONCLUSION: Consistent with our hypothesis, CRI detected low-volume blood loss with significantly greater specificity than other traditional physiologic measures. These findings warrant further evaluation of the CRI algorithm in actual trauma settings. (Copyright 0 2014 by Lippincott Williams & Wilkins)
引用
收藏
页码:897 / 898
页数:2
相关论文
共 40 条
[11]   Estimation of individual-specific progression to impending cardiovascular instability using arterial waveforms [J].
Convertino, Victor A. ;
Grudic, Greg ;
Mulligan, Jane ;
Moulton, Steve .
JOURNAL OF APPLIED PHYSIOLOGY, 2013, 115 (08) :1196-1202
[12]   Use of Advanced Machine-Learning Techniques for Noninvasive Monitoring of Hemorrhage [J].
Convertino, Victor A. ;
Moulton, Steven L. ;
Grudic, Gregory Z. ;
Rickards, Caroline A. ;
Hinojosa-Laborde, Carmen ;
Gerhardt, Robert T. ;
Blackbourne, Lorne H. ;
Ryan, Kathy L. .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2011, 71 :S25-S32
[13]   Lower body negative pressure as a model to study progression to acute hemorrhagic shock in humans [J].
Cooke, WH ;
Ryan, KL ;
Convertino, VA .
JOURNAL OF APPLIED PHYSIOLOGY, 2004, 96 (04) :1249-1261
[14]   Muscle sympathetic nerve activity during intense lower body negative pressure to presyncope in humans [J].
Cooke, William H. ;
Rickards, Caroline A. ;
Ryan, Kathy L. ;
Kuusela, Tom A. ;
Convertino, Victor A. .
JOURNAL OF PHYSIOLOGY-LONDON, 2009, 587 (20) :4987-4999
[15]   Resuscitation of Traumatic Shock A Hemodynamic Review [J].
Cottingham, Christine A. .
AACN ADVANCED CRITICAL CARE, 2006, 17 (03) :317-326
[16]   Can near-infrared spectroscopy identify the severity of shock in trauma patients? [J].
Crookes, BA ;
Cohn, SM ;
Bloch, S ;
Amortegui, J ;
Manning, R ;
Li, P ;
Proctor, MS ;
Hallal, A ;
Blackbourne, LH ;
Benjamin, R ;
Soffer, D ;
Habib, F ;
Schulman, CI ;
Duncan, R ;
Proctor, KG .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2005, 58 (04) :806-+
[17]   Admission base deficit predicts transfusion requirements and risk of complications [J].
Davis, JW ;
Parks, SN ;
Kaups, KL ;
Gladen, HE ;
ODonnellNicol, S .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1996, 41 (05) :769-774
[18]   Predicting fluid responsiveness in mechanically ventilated children under general anaesthesia using dynamic parameters and transthoracic echocardiography [J].
de Souza Neto, E. Pereira ;
Grousson, S. ;
Duflo, F. ;
Ducreux, C. ;
Joly, H. ;
Convert, J. ;
Mottolese, C. ;
Dailler, F. ;
Cannesson, M. .
BRITISH JOURNAL OF ANAESTHESIA, 2011, 106 (06) :856-864
[19]  
Dutton R P, 2001, Curr Opin Anaesthesiol, V14, P217, DOI 10.1097/00001503-200104000-00014
[20]   Impact of withdrawal of 450 ml of blood on respiration-induced oscillations of the ear plethysmographic waveform [J].
Gesquiere M.J. ;
Awad A.A. ;
Silverman D.G. ;
Stout R.G. ;
Jablonka D.H. ;
Silverman T.J. ;
Shelley K.H. .
Journal of Clinical Monitoring and Computing, 2007, 21 (05) :277-282