Diagnostic performance and image quality of low- tube voltage and low- contrast medium dose protocol with hybrid iterative reconstruction for hepatic dynamic CT

被引:10
作者
Ichikawa, Shintaro [1 ]
Motosugi, Utaroh [1 ,2 ]
Shimizu, Tatsuya [1 ]
Kromrey, Marie Luise [1 ,3 ]
Aikawa, Yoshihito [4 ]
Tamada, Daiki [1 ]
Onishi, Hiroshi [1 ]
机构
[1] Univ Yamanashi, Dept Radiol, Chuo Ku, 1110 Shimokato, Kofu, Yamanashi, Japan
[2] Kofu Kyoritsu Hosp, Dept Diagnost Radiol, 1-9-1 Takara, Kofu, Yamanashi, Japan
[3] Univ Med Greifswald, Dept Diagnost Radiol & Neuroradiol, Domstr 11, Greifswald, Germany
[4] Univ Yamanashi Hosp, Div Radiol, Chuo Ku, 1110 Shimokato, Kofu, Yamanashi, Japan
关键词
COMPUTED-TOMOGRAPHY; HEPATOCELLULAR-CARCINOMA; THIN ADULTS; 80; KVP; ALGORITHM; LIVER; REDUCTION; DETECTABILITY; LESIONS; RISK;
D O I
10.1259/bjr.20210601
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To evaluate the diagnostic performance and image quality of the low tube voltage and low-contrast medium dose protocol for hepatic dynamic CT. Methods: This retrospective study was conducted between January and May 2018. All patients underwent hepatic dynamic CT using one of the two protocols: tube voltage, 80 kVp and contrast dose, 370 mgI/kg with hybrid iterative reconstruction or tube voltage, 120 kVp and contrast dose, 600 mgI/kg with filtered back projection. Two radiologists independently scored lesion conspicuity and image quality. Another radiologist measured the CT numbers of abdominal organs, muscles, and hepatocellular carcinoma (HCC) in each phase. Lesion detectability, HCC diagnostic ability, and image quality of the arterial phase were compared between the two protocols using the non-inferiority test. CT numbers and HCC- to- liver contrast were compared between the protocols using the Mann-Whitney U test. Results: 424 patients (70.5 +/- 10.1 years) were evaluated. The 80- kVp protocol showed non-inferiority in lesion detectability and diagnostic ability for HCC (sensitivity, 85.7-89.3%; specificity, 96.3-98.6%) compared with the 120- kVp protocol (sensitivity, 91.0-93.3%; specificity, 93.6-97.3%) (p < 0.001-0.038). The ratio of fair image quality in the 80- kVp protocol also showed non inferiority compared with that in the 120- kVp protocol in assessments by both readers (p < 0.001). HCC- to- liver contrast showed no significant differences for all phases (p = 0.309-0.705) between the two protocols. Conclusion: The 80- kVp protocol with hybrid iterative reconstruction for hepatic dynamic CT can decrease iodine doses while maintaining diagnostic performance and image quality compared with the 120- kVp protocol. Advances in knowledge: The 80-and 120- kVp protocols showed equivalent hepatic lesion detectability, diagnostic ability for HCC, image quality, and HCC- to- liver contrast. The 80- kVp protocol showed a 38.3% reduction in iodine dose compared with the 120- kVp protocol.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Image Quality and Diagnostic Performance of Low-Dose Liver CT with Deep Learning Reconstruction versus Standard-Dose CT
    Lee, Dong Ho
    Lee, Jeong Min
    Lee, Chang Hee
    Afat, Saif
    Othman, Ahmed
    RADIOLOGY-ARTIFICIAL INTELLIGENCE, 2024, 6 (02)
  • [32] Ultra-low-dose CT of the Lung: Effect of Iterative Reconstruction Techniques on Image Quality
    Yanagawa, Masahiro
    Gyobu, Tomoko
    Leung, Ann N.
    Kawai, Misa
    Kawata, Yutaka
    Sumikawa, Hiromitsu
    Honda, Osamu
    Tomiyama, Noriyuki
    ACADEMIC RADIOLOGY, 2014, 21 (06) : 695 - 703
  • [33] Ultra-Low-Dose Neck CT With Low-Dose Contrast Material for Preoperative Staging of Thyroid Cancer: Image Quality and Diagnostic Performance
    Yeom, Jeong A.
    Roh, Jieun
    Jeong, Yeon Joo
    Lee, Jin Choon
    Kim, Hyun Yul
    Suh, Young Ju
    Baik, Seung Kug
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2019, 212 (04) : 748 - 754
  • [34] Performance evaluation of two iterative reconstruction algorithms, MBIR and ASIR, in low radiation dose and low contrast dose abdominal CT in children
    Sun, Jihang
    Yang, Lixin
    Zhou, Zuofu
    Zhang, Dan
    Han, Wei
    Zhang, Qifeng
    Peng, Yun
    RADIOLOGIA MEDICA, 2020, 125 (10): : 918 - 925
  • [35] Studies on the radiation dose, image quality and low contrast detectability from MSCT abdomen by using low tube voltage
    Mokhtar, A.
    Aabdelbary, Z. A.
    Sarhan, A.
    Gad, H. M.
    Ahmed, M. T.
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2021, 52 (01)
  • [36] Iterative CT reconstruction in abdominal low-dose CT used for hybrid SPECT-CT applications: effect on image quality, image noise, detectability, and reader's confidence
    Grosser, Oliver S.
    Ruf, Juri
    Kupitz, Dennis
    Czuczwara, Damian
    Loewenthal, David
    Thormann, Markus
    Furth, Christian
    Ricke, Jens
    Denecke, Timm
    Pech, Maciej
    Kreissl, Michael C.
    Amthauer, Holger
    ACTA RADIOLOGICA OPEN, 2019, 8 (06):
  • [37] Patient dose and image quality in low-dose abdominal CT: a comparison between iterative reconstruction and filtered back projection
    Kataria, Bharti
    Smedby, Orjan
    ACTA RADIOLOGICA, 2013, 54 (05) : 540 - 548
  • [38] Use of low tube voltage and low contrast agent concentration yields good image quality for aortic CT angiography
    Wei, L.
    Li, S.
    Gao, Q.
    Liu, Y.
    Ma, X.
    CLINICAL RADIOLOGY, 2016, 71 (12) : 1313.e5 - 1313.e10
  • [39] Low-dose CT for patients with clinically suspected acute appendicitis: optimal strength of sinogram affirmed iterative reconstruction for image quality and diagnostic performance
    Kim, Seung Ho
    Yoon, Jung-Hee
    Lee, Jang Hee
    Lim, Yun-Jung
    Kim, Ok Hwa
    Ryu, Ji Hwa
    Son, Jung-Hee
    ACTA RADIOLOGICA, 2015, 56 (08) : 899 - 907
  • [40] Diagnostic performance and image quality of deep learning image reconstruction (DLIR) on unenhanced low-dose abdominal CT for urolithiasis
    Delabie, Aurelien
    Bouzerar, Roger
    Pichois, Raphael
    Desdoit, Xavier
    Vial, Jeremie
    Renard, Cedric
    ACTA RADIOLOGICA, 2022, 63 (09) : 1283 - 1292