CT exposure in adult and paediatric patients: a review of the mechanisms of damage, relative dose and consequent possible risks

被引:30
作者
Colagrande, Stefano [1 ,2 ]
Origgi, Daniela [3 ]
Zatelli, Giovanna [4 ]
Giovagnoni, Andrea [5 ]
Salerno, Sergio [6 ]
机构
[1] Univ Florence, Dipartimento Sci Biomed Sperimentali & Clin, Florence, Italy
[2] Azienda Osped Univ Careggi, I-50134 Florence, Italy
[3] Ist Europeo Oncol, Dipartimento Fis Med, I-20141 Milan, Italy
[4] Azienda USL 10 Firenze, Dipartimento Fis Sanit, I-50135 Florence, Italy
[5] Univ Politecn Marche, Dipartimento Sci Clin Specialist & Odontostomatol, Sez Sci Radiol, Osped Riuniti, Ancona, Italy
[6] Univ Palermo, AOUP Policlin, Dipartimento Biotecnol & Biotecnol Med & Forensi, I-90127 Palermo, Italy
来源
RADIOLOGIA MEDICA | 2014年 / 119卷 / 10期
关键词
CT; Radiation exposure; DLP; CTDI; Radiation dose; Absorbed dose; COMPUTED-TOMOGRAPHY; IONIZING-RADIATION; DOCTORS KNOWLEDGE; LENGTH PRODUCT; CANCER; CHILDREN; QUALITY;
D O I
10.1007/s11547-014-0393-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
An increase has been observed not only in the absolute number of CT examinations but also in the length of coverage and number of scanning phases, with the result that exposure to ionising radiation from CT is becoming an increasingly serious problem. The extent of the problem is not entirely known and cannot be adequately addressed without proper knowledge of all the phases that leads to the effective dose calculation. In light of the growing awareness of the issue of ionising radiation dose and the possible risk for the individual and the population, there is a need for radiologists, medical physicists and radiographers to play an active role in dose management. In this review, the authors try to delineate the problem in a consequential and multifaceted way: radiation-patient interaction, possible mechanisms of damage, main CT dose units, risk and its quantification in the population, with the aim of optimising the acquisition dose without diagnostic drawbacks. For an "up-to-date'' use of CT, radiologists must know the dose concerns for the single patient and population, and use the CT apparatus with the best dose care; substitute CT with other diagnostic techniques when possible, especially in children; reduce the number/extension of scans and phases, and the dose in single scans and single examinations.
引用
收藏
页码:803 / 810
页数:8
相关论文
共 38 条
[1]  
[Anonymous], 2013, BMJ-BRIT MED J
[2]   Dosimetry for computed tomography examination of children [J].
Axelsson, B ;
Persliden, J ;
Schuwert, P .
RADIATION PROTECTION DOSIMETRY, 1996, 64 (03) :221-226
[3]  
Balonov M. I., 2012, Annals of the ICRP, V41, P129, DOI 10.1016/j.icrp.2012.06.002
[4]   Iterative reconstruction methods in X-ray CT [J].
Beister, Marcel ;
Kolditz, Daniel ;
Kalender, Willi A. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2012, 28 (02) :94-108
[5]   Current concepts - Computed tomography - An increasing source of radiation exposure [J].
Brenner, David J. ;
Hall, Eric J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) :2277-2284
[6]   Cancer risks attributable to low doses of ionizing radiation: Assessing what we really know [J].
Brenner, DJ ;
Doll, R ;
Goodhead, DT ;
Hall, EJ ;
Land, CE ;
Little, JB ;
Lubin, JH ;
Preston, DL ;
Preston, RJ ;
Puskin, JS ;
Ron, E ;
Sachs, RK ;
Samet, JM ;
Setlow, RB ;
Zaider, M .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2003, 100 (24) :13761-13766
[7]   Estimated risks of radiation-induced fatal cancer from pediatric CT [J].
Brenner, DJ ;
Elliston, CD ;
Hall, EJ ;
Berdon, WE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) :289-296
[8]  
Chen W. L., 2007, Dose-Response, V5, P63, DOI 10.2203/dose-response.06-105.Chen
[9]  
Commissione Europea, 2000, LINEE GUIDA PER LESP
[10]   Review of radiation issues for computed tomography [J].
Frush, DP .
SEMINARS IN ULTRASOUND CT AND MRI, 2004, 25 (01) :17-24