Accuracy of Eclipse Electron Macro Monte Carlo Dose Algorithm for Use in Bolus Electron Conformal Therapy

被引:0
作者
Carver, R. [1 ]
Popple, R. [2 ]
Antolak, J. [3 ]
Sprunger, C. [4 ]
Benhabib, S. [2 ]
Hogstrom, K. [1 ,4 ]
机构
[1] Mary Bird Perkins Canc Ctr, Baton Rouge, LA USA
[2] Univ Alabama Birmingham, Birmingham, AL USA
[3] Mayo Clin, Rochester, MN USA
[4] Louisiana State Univ, Baton Rouge, LA 70803 USA
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
SU-E-T-356
引用
收藏
页码:306 / 306
页数:1
相关论文
共 50 条
[41]   Is wax equivalent to tissue in electron conformal therapy planning? A Monte Carlo study of material approximation introduced dose difference [J].
Zhang, Ray R. ;
Feygelman, Vladimir ;
Harris, Eleanor R. ;
Rao, Nikhil ;
Moros, Eduardo G. ;
Zhang, Geoffrey G. .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (01) :92-101
[42]   Detector selection for commissioning of a Monte Carlo based electron dose calculation algorithm [J].
Anusionwu, Princess ;
Aviles, Jorge E. Alpuche ;
Pistorius, Stephen .
MEDICAL PHYSICS, 2016, 43 (08) :4940-4940
[43]   Evaluation of a Commercial Monte Carlo Dose Calculation Algorithm for Electron Treatment Planning [J].
Huang, J. ;
Dunkerley, D. ;
Smilowitz, J. .
MEDICAL PHYSICS, 2018, 45 (06) :E546-E546
[44]   Evaluation of a commercial Monte Carlo dose calculation algorithm for electron treatment planning [J].
Huang, Jessie Y. ;
Dunkerley, David ;
Smilowitz, Jennifer B. .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (06) :184-193
[45]   Evaluation of a new commercial Monte Carlo dose calculation algorithm for electron beams [J].
Vandervoort, Eric J. ;
Tchistiakova, Ekaterina ;
La Russa, Daniel J. ;
Cygler, Joanna E. .
MEDICAL PHYSICS, 2014, 41 (02) :021711
[46]   The Effect of Smoothing on the Uncertainty in the Dose Distributions for a Commercial Electron Monte Carlo Algorithm [J].
Salomons, G. ;
Darko, J. .
MEDICAL PHYSICS, 2010, 37 (06)
[47]   EVALUATION OF AN ELECTRON MONTE CARLO DOSE CALCULATION ALGORITHM AFTER A SOFTWARE UPGRADE [J].
Petillion, S. ;
Swinnen, A. ;
Van den Heuvel, F. .
RADIOTHERAPY AND ONCOLOGY, 2009, 92 :S223-S224
[48]   Comparison of Measurements and Eclipse Electron Monte Carlo Calculations for Small Electron Fields with Central Block [J].
Ivanova, T. ;
Kassaee, A. .
MEDICAL PHYSICS, 2010, 37 (06) :3263-+
[49]   Commissioning of Electron Monte Carlo in Eclipse Treatment Planning System for TrueBeam [J].
Yang, X. ;
Lasio, G. ;
Zhou, J. ;
Lin, M. ;
Yi, B. ;
Guerrero, M. .
MEDICAL PHYSICS, 2014, 41 (06) :362-362
[50]   Assessment of Eclipse electron Monte Carlo output prediction for various topologies [J].
Lawrence, Shane L. ;
van Lieshout, Natascha H. M. ;
Charland, Paule M. .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (03) :99-106