A new fault location scheme for parallel transmission lines using one-terminal data

被引:10
|
作者
Saber, A. [1 ]
Zeineldin, H. H. [1 ,2 ]
EL-Fouly, Tarek H. M. [2 ]
Al-Durra, Ahmed [2 ]
机构
[1] Cairo Univ, Elect Power Engn Dept, Giza, Egypt
[2] Khalifa Univ, Adv Power & Energy Ctr, Elect Engn & Comp Sci Dept, Abu Dhabi, U Arab Emirates
关键词
Phase-Coordinates; Parallel Transmission Lines; Fault Location; One-Terminal Measurements; LIMITED NUMBER; ALGORITHM; VOLTAGE; PROTECTION;
D O I
10.1016/j.ijepes.2021.107548
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper proposes a fault location (FL) scheme for a two-terminal double-circuit transmission line using oneterminal current and voltage measurements. As the proposed scheme is formulated in the phase-coordinates, the parallel transmission lines are not required to be decoupled, and the proposed scheme can be applied for transposed or untransposed lines. In addition, the proposed scheme takes into account the line asymmetry and the potential couplings between the phases of the same circuit or different circuits. The derived FL equation is based on two concepts. The first concept is that the fault impedance is mainly resistive component. The second one is that the voltages of the similar phases in both circuits at each line terminal are equal to each other. Further, a new fault classification method is introduced to recognize the faulted phases, which are initially required to apply the proposed FL scheme. Moreover, the IEEE 39-bus system is deployed as a test case, and it is simulated on PSCAD/EMTDC software. The frequency-dependent phase model is used to emulate the parallel transmission lines. All fault types, including the cross-circuit faults, are tested considering different fault resistances and locations. In addition, the effect of the measurement errors on the fault location accuracy is investigated.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Fault Location for Interline Fault of Parallel Transmission Lines Using One-terminal Data
    Xu, Gang
    Yu, Sheng
    Xu, Zhenyu
    2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 2014 - +
  • [2] An accurate fault location algorithm for parallel transmission lines using one-terminal data
    Song Guobing
    Jiale, Suonan
    Ge Yaozhong
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2009, 31 (2-3) : 124 - 129
  • [3] Fault location in transmission lines using one-terminal postfault voltage data
    De Pereira, CE
    Zanetta, LC
    IEEE TRANSACTIONS ON POWER DELIVERY, 2004, 19 (02) : 570 - 575
  • [4] Fault location for parallel transmission lines using one-terminal current traveling waves
    徐青山
    Journal of Harbin Institute of Technology, 2009, 16 (03) : 408 - 412
  • [6] Long Transmission Lines Fault Location Based on Parameter Identification Using One-Terminal Data
    Wang, Bin
    Suonan, Jiale
    Liu, Heqing
    Song, Guobing
    2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,
  • [7] Transmission line fault location for phase-to-earth fault using one-terminal data
    Zhang, Q
    Zhang, Y
    Song, W
    Yu, Y
    IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 1999, 146 (02) : 121 - 124
  • [8] Fault location of two-parallel transmission line for non-earth fault using one-terminal data
    Zhang, QC
    Zhang, Y
    Song, WN
    Yu, YX
    Wang, ZG
    IEEE TRANSACTIONS ON POWER DELIVERY, 1999, 14 (03) : 863 - 867
  • [9] Time-domain fault location algorithm based on one-terminal current of parallel transmission lines
    School of Electric Engineering, Xi'an Jiaotong University, Xi'an 710049, China
    Zhongguo Dianji Gongcheng Xuebao, 2007, 7 (52-57):
  • [10] Fault location of two-parallel transmission line for double phase-to-earth fault using one-terminal data
    Zhang Qing-chao
    Duan Hui
    Geng Chao
    Song Wen-nan
    Journal of Zhejiang University-SCIENCE A, 2003, 4 (5): : 520 - 525