Fouling in hollow fiber membrane microfilters used for household water treatment

被引:11
作者
Murray, Anna [1 ]
Goeb, Mario [2 ]
Stewart, Barbara [3 ]
Hopper, Catherine [4 ]
Peck, Jamin [5 ]
Meub, Carolyn [5 ]
Asatekin, Ayse [6 ]
Lantagne, Daniele [1 ]
机构
[1] Tufts Univ, Dept Civil & Environm Engn, Medford, MA 02155 USA
[2] Pure Water World, Trojes, Honduras
[3] Univ Maine, Dept Chem, Orono, ME 04469 USA
[4] Univ Maine, Dept Mol & Biomed Sci, Orono, ME USA
[5] Pure Water World, Rutland, VT USA
[6] Tufts Univ, Dept Chem & Biol Engn, Medford, MA 02155 USA
基金
美国国家科学基金会;
关键词
drinking water; filter fouling; hollow fiber membrane; household water treatment; microfiltration; point-of-use; NATURAL ORGANIC-MATTER; SURFACE-WATER; ULTRAFILTRATION; PERFORMANCE;
D O I
10.2166/washdev.2015.206
中图分类号
TV21 [水资源调查与水利规划];
学科分类号
081501 ;
摘要
The Sawyer PointOne hollow fiber membrane microfilter is promoted for household water treatment in developing countries. Critical limitations of membrane filtration are reversible and irreversible membrane fouling, managed by backwashing and chemical cleaning, respectively. The PointOne advertised lifespan is 10 years; users are instructed to backwash as maintenance. Owing to reduced turbidity and bacterial removal efficiencies, six PointOnes were removed from Honduran homes after 23 months of use. In the laboratory, we tested sterile water filtrate for turbidity and bacterial presence before and after backwashing and chemical cleaning. Sterile water filtrate from uncleaned filters had turbidity of 144-200 NTU and bacteria counts of 13-200 CFU. Cleaned filter effluent was positive for total coliforms. On one new and one used, cleaned filter, we imaged membranes with scanning electron microscopy and characterized surface elemental compositions with spectroscopy. Images and spectroscopy of the used, cleaned membrane revealed a dense, cake fouling layer consisting of inorganic metal oxides, organic material, and biofouling. Burst fibers were visually observed. This PointOne was thus irreversibly fouled and non-functional after <2 years of use. Further research is recommended to determine: impacts of source water quality on PointOne performance, a cleaning regimen to manage fouling, and an appropriate filter lifespan.
引用
收藏
页码:220 / 228
页数:9
相关论文
共 25 条
  • [1] Ultrafiltration of water containing natural organic matter: heavy metal removing in the hybrid complexation-ultrafiltration process
    Alpatova, A
    Verbych, S
    Bryk, M
    Nigmatullin, R
    Hilal, N
    [J]. SEPARATION AND PURIFICATION TECHNOLOGY, 2004, 40 (02) : 155 - 162
  • [2] [Anonymous], 2014, WHO International Scheme to Evaluate Household Water Treatment Technologies. General Testing Protocol #6: Ceramic Pot Gravity Flow Mechanical Filtration Batch System Technology (with and without a silver component)
  • [3] [Anonymous], SAW WAT FILT TECHN
  • [4] [Anonymous], 2012, Progress on Drinking Water and Sanitation 2012 Update
  • [5] [Anonymous], 2018, Guidelines for Drinking Water Quality
  • [6] [Anonymous], 2011, EVALUATING HOUSEHOLD
  • [7] Brune L., 2013, Monitoring and Evaluation of a Pointof- Use Water Treatment Pilot Project in the Peruvian Amazon
  • [8] Membrane fouling control in ultrafiltration technology for drinking water production: A review
    Gao, Wei
    Liang, Heng
    Ma, Jun
    Han, Mei
    Chen, Zhong-lin
    Han, Zheng-shuang
    Li, Gui-bai
    [J]. DESALINATION, 2011, 272 (1-3) : 1 - 8
  • [9] Give Clean Water, 2009, POINT ON FILT FIELD
  • [10] Goeb M., 2013, Anticipated timeline to ensure the sustainability of interventions with Sawyer filters in Trojes, Honduras