Voltage control; Tuning; Power harmonic filters; Harmonic analysis; Robustness; Pulse width modulation; Phase locked loops; Power grids; Power converters; Robust control; Evolutionary computation; Grid-tied converter; multiresonant controllers; robust control; Naslin polynomial method; disk margin analysis; evolutionary global optimization; TRANSIENT-RESPONSE CONTROL; PERFORMANCE; COMPENSATION; OPTIMIZATION; LOOP;
D O I
10.1109/ACCESS.2022.3199702
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The majority of the paper is devoted to debunking flawed methods proposed in the literature within the context of multiresonant control systems for grid-connected converters and then a novel approach is proposed. Several flawed approaches to grid tied power electronic converters (rectifiers and shunt active power filters) are discussed to initiate a critical discussion regarding some tuning methods reported in the topical literature. In this paper we analytically show that some of them are even erroneous from the control theory point of view or are based on mathematically erroneous derivations. That is especially prevalent for papers in which the Naslin polynomial method is employed to tune proportional-multiresonant controllers. Some authors recognize that the resulting control systems are not robust, i.e. not practical, and use obtained gains only as a starting point for further tuning using the trial and error method or evolutionary global optimization. Robustness of such systems is often not guaranteed and if it occurs at all, it is by chance or thanks to a combination of luck and expert knowledge of the engineer (not by deliberate design). Therefore, the absence of such a guarantee motivates the search for better ways to tune such controllers. As a result, a practical robust controller tuning method for multiresonant grid current controllers is proposed and verified experimentally. We are convinced that one of the solutions can be based on the disk margin stability analysis and a global search algorithm. The required robustness is expressed as stability margins. The design procedure is very user-friendly and the disk size is the key design parameter to be selected by an engineer. The practicality of the tuning method is demonstrated empirically in a 10 kVA physical grid-tied converter.
引用
收藏
页码:88211 / 88225
页数:15
相关论文
共 50 条
  • [1] A New Tuning Method of Multiresonant Current Controllers for Grid-Connected Voltage Source Converters
    Xie, Chuan
    Zhao, Xin
    Li, Kai
    Zou, Jianxiao
    Guerrero, Josep M.
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2019, 7 (01) : 458 - 466
  • [2] An Approach to Increase the Bandwidth of Current Controllers for Grid-tied Converters with LCL Filter
    de Assuncao, Marcos Paulo F.
    Ribeiro, Luiz A. de S.
    de Matos, Jose G.
    Freijedo, Francisco D.
    2019 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2019, : 3764 - 3768
  • [3] Optimized parametrization of adaptive controllers for enhanced current regulation in grid-tied converters
    Hollweg, Guilherme Vieira
    Evald, Paulo Jefferson Dias de Oliveira
    Mattos, Everson
    Borin, Lucas Cielo
    Tambara, Rodrigo Varella
    Montagner, Vinicius Foletto
    INTERNATIONAL JOURNAL OF ADAPTIVE CONTROL AND SIGNAL PROCESSING, 2024, 38 (01) : 200 - 220
  • [4] Optimization of Robust PI Controllers for Grid-Tied Inverters
    Osorio, Caio R. D.
    Borin, Lucas C.
    Koch, Gustavo G.
    Montagner, Vinicius F.
    2019 IEEE 15TH BRAZILIAN POWER ELECTRONICS CONFERENCE AND 5TH IEEE SOUTHERN POWER ELECTRONICS CONFERENCE (COBEP/SPEC), 2019,
  • [5] Improved Resonant Current Controller for Grid-Tied Converters
    Perez-Estevez, Diego
    Doval-Gandoy, Jesus
    Yepes, Alejandro G.
    Lopez, Oscar
    Baneira, Fernando
    2017 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2017, : 3877 - 3884
  • [6] Application of Resonant Controllers for Current Harmonic Suppression and Rejection in Grid-Tied Modular Multilevel Converters
    Bach, Amandus
    Aguilar, Raul Santiago Munoz
    Colak, Ilknur
    IECON 2021 - 47TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2021,
  • [7] Harmonic Compensation Method of Grid-Tied Converters in a Weak Grid
    Deng Hua
    Li Guanyang
    Cui Chen
    Wang Shanlong
    Zhao Zhongtian
    Wang Hongzhao
    2017 CHINESE AUTOMATION CONGRESS (CAC), 2017, : 6928 - 6933
  • [8] Dynamics estimation and generalized tuning of stationary frame current controller for grid-tied power converters
    Zhang, Weiyi
    Remon, Daniel
    Cantarellas, Antoni M.
    Luna, Alvaro
    Rodriguez, Pedro
    EPE JOURNAL, 2016, 26 (03) : 85 - 95
  • [9] A performance comparison of current controllers for grid-tied photovoltaic microinverters
    Jung, Felipe
    Pereira, Thiago A.
    Rech, Thiago Fonseca
    Coelho, Roberto F.
    Kirsten, Andre Luis
    INTERNATIONAL JOURNAL OF CIRCUIT THEORY AND APPLICATIONS, 2025, 53 (01) : 163 - 174
  • [10] Self-tuning methodology for adaptive controllers based on genetic algorithms applied for grid-tied power converters
    Hollweg, Guilherme Vieira
    Evald, Paulo Jefferson Dias de Oliveira
    Mattos, Everson
    Borin, Lucas Cielo
    Tambara, Rodrigo Varella
    Montagner, Vinicius Foletto
    CONTROL ENGINEERING PRACTICE, 2023, 135