Behaviour of electrical cables under fire conditions

被引:0
|
作者
Bertrand, R [1 ]
Chaussard, M [1 ]
Gonzalez, R [1 ]
Lacoue, J [1 ]
Mattei, JM [1 ]
Such, JM [1 ]
机构
[1] SERS, DES, Inst Radiol Protect & Nucl Safety, F-92265 Fontenay Aux Roses, France
关键词
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A Fire Probabilistic Safety Assessment - called the Fire PSA is being carried out by the French Institute of Radiological Protection and Nuclear Safety (IRSN) to be used in the framework of the safety, assessment of operating 900 MWe PWRs. The aim of this study, is to evaluate the core damage conditional probability, which could result from a fire. A fire can induce unavailability of safety, equipment, notably damaging electrical cables introducing a significant risk contributor. The purpose of this paper is to present the electrical cable fire tests carried out by IRSN to identify, the failure modes and to determine the cable damage criteria. The impact of each kind of cable failure mode and the methodology, used to estimate the conditional probability, of a failure mode when cable damage occurred is also discussed.
引用
收藏
页码:116 / 120
页数:5
相关论文
共 50 条
  • [21] Effect of passive protection on fire propagation of electrical cables
    Zeng, Dong
    Wang, Yi
    Boardman, Daniel
    FIRE AND MATERIALS, 2021, 45 (03) : 345 - 354
  • [22] Evaluating the fire-safety characteristics of electrical cables
    Larina, E.T.
    Krekhova, O.V.
    Kamenskii, M.K.
    Soviet electrical engineering, 1988, 59 (12): : 33 - 38
  • [23] IMPROVEMENT IN FIRE SAFETY FEATURES OF ELECTRICAL CONDUCTORS AND CABLES
    MCCLUNG, LB
    RAMACHANDRAN, S
    IEEE TRANSACTIONS ON POWER DELIVERY, 1995, 10 (01) : 43 - 52
  • [24] ELECTRICAL CABLES - A LESS SIGNIFICANT FACTOR IN FIRE.
    Mehaffey, James
    Richardson, Kenneth
    Canadian Consulting Engineer, 1985, 27 (08) : 29 - 32
  • [25] FLAME INHIBITION AND REQUIREMENTS FOR SPREADING OF FIRE IN ELECTRICAL CABLES
    GLAEVER, J
    KAUTSCHUK GUMMI KUNSTSTOFFE, 1983, 36 (10): : 880 - 880
  • [26] FIRE PROTECTIVE COATING SYSTEM FOR SHIPBOARD ELECTRICAL CABLES
    WARD, TA
    YKEMA, JI
    NAVAL ENGINEERS JOURNAL, 1990, 102 (03) : 154 - 161
  • [27] Stability behaviour of sinusoidal corrugated web girders under fire conditions
    Kollár, Dénes
    ce/papers, 2023, 6 (3-4) : 2020 - 2025
  • [28] AN EXAMINATION OF THE BEHAVIOUR OF THERMALLY TREATED SPRUCE WOOD UNDER FIRE CONDITIONS
    Martinka, Jozef
    Chrebet, Tomas
    Kral, Jan
    Balog, Karol
    WOOD RESEARCH, 2013, 58 (04) : 599 - 605
  • [29] Behaviour and design of beam-to-column connections under fire conditions
    Ramli-Sulong, N. H.
    Elghazouli, A. Y.
    Izzuddin, B. A.
    FIRE SAFETY JOURNAL, 2007, 42 (6-7) : 437 - 451
  • [30] Prediction of wood and wood products behaviour under real fire conditions
    Martinka, Jozef
    Hrusovsky, Ivan
    Rantuch, Peter
    Balog, Karol
    FIRE PROTECTION, SAFETY AND SECURITY 2017, 2017, : 101 - 105