Biocompatibility of titanium from the viewpoint of its surface

被引:54
作者
Hanawa, Takao [1 ,2 ,3 ]
机构
[1] Tokyo Med & Dent Univ, Inst Biomat & Bioengn, Tokyo, Japan
[2] Kobe Univ, Ctr Adv Med Engn Res & Dev, Kobe, Hyogo, Japan
[3] Osaka Univ, Grad Sch Engn, Div Mat & Mfg Sci, Osaka, Japan
关键词
Titanium; passive film; corrosion resistance; surface electric charge; electrostatic force; band gap energy; biocompatibility; ORTHOPEDIC IMPLANT ALLOYS; CHEMICAL-VAPOR-DEPOSITION; FRICTION-WEAR PROPERTIES; CR-MO ALLOY; PASSIVE FILMS; OPTICAL-PROPERTIES; OXIDE-FILMS; ANODIC POLARIZATION; THIN-FILMS; BAND-STRUCTURE;
D O I
10.1080/14686996.2022.2106156
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Among metals, Ti and majority of its alloys exhibit excellent biocompatibility or tissue compatibility. Although their high corrosion resistance is a factor in the biocompatibility of Ti and Ti alloys, it is clear that other factors exist. In this review, the corrosion resistance and passive film of Ti are compared to those of other metallic biomaterials, and their band gap energies, E(g)s, are compared to discuss the role of E-g in the reactivity with living tissues. From the perspective of the material's surface, it is possible to explain the excellent biocompatibility of Ti by considering the following factors: Ti ions are immediately stabilized not to show toxicity if it is released to body fluids; good balance of positive and negative charges by the dissociation of surface hydroxyl groups on the passive film; low electrostatic force of the passive film inducing a natural adsorption of proteins maintaining their natural conformation; strong property as n-type semiconductor; lower band gap energy of the passive film on Ti generating optimal reactivity; and calcium phosphate formation is caused by this reactivity. The results suggest that due to the passive oxide film, the optimal balance between high corrosion resistance and appropriate reactivity of Ti is the predominate solution for the excellent biocompatibility of Ti.
引用
收藏
页码:457 / 472
页数:16
相关论文
共 146 条
[1]   Corrosion of spinal implants retrieved from patients with scoliosis [J].
Akazawa, T ;
Minami, S ;
Takahashi, K ;
Koiani, T ;
Hanawa, T ;
Moriya, H .
JOURNAL OF ORTHOPAEDIC SCIENCE, 2005, 10 (02) :200-205
[2]  
[Anonymous], 1987, P CONSENSUS C EUROPE
[3]   PHOTOELECTROCHEMICAL PROPERTIES OF ANODIC OXIDE FILM ON NIOBIUM [J].
ARITA, M ;
HAYASHI, Y .
MATERIALS TRANSACTIONS JIM, 1994, 35 (04) :233-237
[4]   THE SURFACE CHARACTERIZATION OF TITANIUM AND TITANIUM-NICKEL ALLOYS IN SULFURIC-ACID [J].
ASAMI, K ;
CHEN, SC ;
HABAZAKI, H ;
HASHIMOTO, K .
CORROSION SCIENCE, 1993, 35 (1-4) :43-49
[5]   X-RAY PHOTOELECTRON-SPECTRA OF SEVERAL OXIDES OF IRON AND CHROMIUM [J].
ASAMI, K ;
HASHIMOTO, K .
CORROSION SCIENCE, 1977, 17 (07) :559-570
[6]   Corrosion and surface modification on biocompatible metals: A review [J].
Asri, R. I. M. ;
Harun, W. S. W. ;
Samykano, M. ;
Lah, N. A. C. ;
Ghani, S. A. C. ;
Tarlochan, F. ;
Raza, M. R. .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2017, 77 :1261-1274
[7]   ELECTROCHEMISTRY OF FRESHLY-GENERATED TITANIUM SURFACES .1. SCRAPED ROTATING-DISK EXPERIMENTS [J].
BECK, TR .
ELECTROCHIMICA ACTA, 1973, 18 (11) :807-814
[8]   Band offsets of ultrathin high-κ oxide films with Si [J].
Bersch, Eric ;
Rangan, Sylvie ;
Bartynski, Robert Allen ;
Garfunkel, Eric ;
Vescovo, Elio .
PHYSICAL REVIEW B, 2008, 78 (08)
[9]   EXPERIMENTAL LONG-TERM STUDY OF TITANIUM IONS ELUTED FROM PURE TITANIUM MINIPLATES [J].
BESSHO, K ;
FUJIMURA, K ;
IIZUKA, T .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1995, 29 (07) :901-904
[10]  
Bianco PD, 1996, J BIOMED MATER RES, V31, P227