Feasibility and safety of high-power ablation of atrial fibrillation with contact force-sensing catheter: The lesion size index-guided ablation

被引:2
|
作者
Parwani, Abdul Shokor [1 ]
Hohendanner, Felix [1 ]
Kluck, Amelie [1 ]
Blaschke, Florian [1 ]
Pieske, Burkert [1 ]
Boldt, Leif-Hendrik [1 ]
机构
[1] Charite Univ Med Berlin, Campus Virchow Klinikum, Berlin, Germany
来源
ADVANCES IN CLINICAL AND EXPERIMENTAL MEDICINE | 2022年 / 31卷 / 07期
关键词
atrial fibrillation; high-power ablation; lesion size index; contact force sensing; PULMONARY VEIN ISOLATION; SHORT-DURATION ABLATION;
D O I
10.17219/acem/146917
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background. Radiofrequency (RF) ablation is a commonly used method of atrial fibrillation (AF) treatment. High-power short-duration (HPSD) ablation has been suggested as a method to reduce procedure times whilst creating safe and lasting lesions. High-power ablation with contact force (CF)-sensing technology catheters might aid in a further improvement of safety whilst generating lasting transmural lesions. Objectives. We report our experience using lesion size index (LSI)-guided 50 W ablation with a CF-sensing catheter of AF. Materials and methods. We performed LSI-guided 50 W point-by-point ablation using a CF-sensing catheter (TactiCath). Target LSI at the anterior left atrium (LA) was 5.0 and at the posterior LA it was 4.5. Results. Altogether, 4641 RF lesions were created in 86 consecutive patients. To reach a mean LSI of 4.9 +/- 0.01, a mean RF ablation time of 14.3 +/- 0.1 s was applied with a mean CF of 13.4 +/- 0.1 g. The RF time per lesion at the anterior wall of LA was 15.9 +/- 0.2 s, while it was 13 +/- 0.2 s at the posterior wall of LA. We observed force time integral (FTI) values between 36 g and 310 g. Procedure duration was 107 +/- 4 min with a RF ablation time of 15.4 +/- 0.6 min. No audible steam pops occurred. No pericardial effusion was observed. After a 1-year follow-up, no adverse events were reported and 83% of patients had no symptomatic arrhythmia recurrence. Conclusions. We provide evidence for the safety and efficacy of LSI-guided 50 W ablation using the TactiCath CF-sensing ablation catheter. These data support the use of high-power ablation with CF sensing technology to improve both safety and efficacy.
引用
收藏
页码:715 / 721
页数:7
相关论文
共 50 条
  • [21] Actual tissue temperature during ablation index-guided high-power short-duration ablation versus standard ablation: Implications in terms of the efficacy and safety of atrial fibrillation ablation
    Otsuka, Naoto
    Okumura, Yasuo
    Kuorkawa, Sayaka
    Nagashima, Koichi
    Wakamatsu, Yuji
    Hayashida, Satoshi
    Ohkubo, Kimie
    Nakai, Toshiko
    Hao, Hiroyuki
    Takahashi, Rie
    Taniguchi, Yoshiki
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2022, 33 (01) : 55 - 63
  • [22] Comparison of myocardial injury and inflammation between ablation index-guided and conventional contact force-guided ablation in atrial fibrillation patients
    Yano, Masamichi
    Egami, Yasuyuki
    Kawanami, Shodai
    Sugae, Hiroki
    Ukita, Kohei
    Kawamura, Akito
    Nakamura, Hitoshi
    Yasumoto, Koji
    Tsuda, Masaki
    Okamoto, Naotaka
    Matsunaga-Lee, Yasuharu
    Nishino, Masami
    Tanouchi, Jun
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2023, 66 (09) : 2021 - 2030
  • [23] Short and Long-Term Outcomes of Lesion Index-Guided High-Power Short-Duration Approach for Atrial Fibrillation Ablation
    Di Cori, Andrea
    Parollo, Matteo
    Gentile, Francesco
    Pistelli, Lorenzo
    Vitale, Carlo
    Della Volpe, Salvatore
    Santoro, Mario Giannotti
    Mazzocchetti, Lorenzo
    De Lucia, Raffaele
    Canu, Antonio
    Barletta, Valentina
    Grifoni, Gino
    Segreti, Luca
    Bongiorni, Maria Grazia
    Zucchelli, Giulio
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (15)
  • [24] Long-termoutcome of high-power ablation guided by ablation index in the treatment of atrial fibrillation
    Mao, Shaobin
    Wang, Leigang
    Fan, Hongxuan
    Yang, Ling
    Wang, Xun
    Liang, Bin
    JOURNAL OF ARRHYTHMIA, 2024, 40 (03) : 455 - 462
  • [25] Ablation Index-guided high-power (50 W) short-duration for left atrial anterior and roofline ablation: Feasibility, procedural data, and lesion analysis (AI High-Power Linear Ablation)
    Zanchi, Simone
    Chen, Shaojie
    Bordignon, Stefano
    Bianchini, Lorenzo
    Tohoku, Shota
    Bologna, Fabrizio
    Tondo, Claudio
    Chun, K. R. Julian
    Schmidt, Boris
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2021, 32 (04) : 984 - 993
  • [26] Persistent Atrial Fibrillation Ablation With Contact Force-Sensing Catheter The Prospective Multicenter PRECEPT Trial
    Mansour, Moussa
    Calkins, Hugh
    Osorio, Jose
    Pollak, Scott J.
    Melby, Daniel
    Marchlinski, Francis E.
    Athill, Charles A.
    Delaughter, Craig
    Patel, Anshul M.
    Gentlesk, Philip J.
    DeVille, Brian
    Macle, Laurent
    Ellenbogen, Kenneth A.
    Dukkipati, Srinivas R.
    Reddy, Vivek Y.
    Natale, Andrea
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2020, 6 (08) : 958 - 969
  • [27] Comparison of Cryoballoon and Ablation Index-Guided Radiofrequency Ablation in Paroxysmal Atrial Fibrillation
    Bocz, Botond
    Debreceni, Dorottya
    Janosi, Kristof-Ferenc
    Torma, Dalma
    Kupo, Peter
    JOURNAL OF CLINICAL MEDICINE, 2025, 14 (06)
  • [28] Economic impact of contact force sensing in catheter ablation for atrial fibrillation
    Mansour, Moussa
    Reddy, Vivek Y.
    Karst, Edward
    Heist, Edwin Kevin
    Packer, Douglas L.
    Dalal, Nirav
    Agarwal, Rahul
    Calkins, Hugh
    Ruskin, Jeremy N.
    Mahapatra, Srijoy
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (11) : 2302 - 2309
  • [29] High-power short-duration catheter ablation of atrial fibrillation: is it really a new era? Comparison between new and old radiofrequency contact force-sensing catheters
    Dello Russo, Antonio
    D'Angelo, Leonardo
    Compagnucci, Paolo
    Cipolletta, Laura
    Parisi, Quintino
    Valeri, Yari
    Campanelli, Francesca
    Volpato, Giovanni
    Carboni, Laura
    Ciliberti, Giuseppe
    Stronati, Giulia Emily
    Barbarossa, Alessandro
    La Piscopia, Valentina
    Bondavalli, Barbara
    Guerra, Federico
    Natale, Andrea
    Casella, Michela
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2024, 67 (03) : 549 - 557
  • [30] Efficiency and safety of high-power ablation guided by Lesion size index: An ex vivo porcine heart study
    Huo, Shengqi
    Wang, Qian
    Jiang, Yue
    Shi, Wei
    Luo, Pengcheng
    Guo, Junyi
    Peng, Dewei
    Zhu, Mengying
    Men, Lintong
    Jiang, Tao
    Wang, Moran
    Peng, Lulu
    Huang, Bingyu
    Shi, Meijing
    Zhu, Bo
    Bai, Rong
    Day, John D. D.
    Lv, Jiagao
    Lin, Li
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2023, 46 (06): : 487 - 497