Development and validation of a virtual reality transrectal ultrasound guided prostatic biopsy simulator

被引:22
|
作者
Chalasani, Venu [1 ,2 ,3 ,4 ]
Cool, Derek W. [5 ]
Sherebrin, Shi [5 ]
Fenster, Aaron [5 ]
Chin, Joseph [1 ,2 ,3 ,4 ]
Izawa, Jonathan I. [1 ,2 ,3 ,4 ]
机构
[1] Univ Western Ontario, Dept Surg, Div Urol, Schulich Sch Med & Dent, London, ON N6A 3K7, Canada
[2] Univ Western Ontario, Dept Surg, Div Surg Oncol, Schulich Sch Med & Dent, London, ON N6A 3K7, Canada
[3] Univ Western Ontario, Dept Oncol, Div Urol, Schulich Sch Med & Dent, London, ON N6A 3K7, Canada
[4] Univ Western Ontario, Dept Oncol, Div Surg Oncol, Schulich Sch Med & Dent, London, ON N6A 3K7, Canada
[5] Univ Western Ontario, Robarts Res Inst, London, ON, Canada
来源
CUAJ-CANADIAN UROLOGICAL ASSOCIATION JOURNAL | 2011年 / 5卷 / 01期
关键词
CANCER; SYSTEM; UROLOGY; SEXTANT; SKILLS;
D O I
10.5489/cuaj.09159
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Objective: We present the design, reliability, face, content and construct validity testing of a virtual reality simulator for transrectal ultrasound (TRUS), which allows doctors-in-training to perform multiple different biopsy schemes. Methods: This biopsy system design uses a regular "end-firing" TRUS probe. Movements of the probe are tracked with a micro-magnetic sensor to dynamically slice through a phantom patient's 3D prostate volume to provide real-time continuous TRUS views. 3D TRUS scans during prostate biopsy clinics were recorded. Intrinsic reliability was assessed by comparing the left side of the prostate to the right side of the prostate for each biopsy. A content and face validity questionnaire was administered to 26 doctors to assess the simulator. Construct validity was assessed by comparing notes from experts and novices with regards to the time taken and the accuracy of each biopsy. Results: Imaging data from 50 patients were integrated into the simulator. The completed VR TRUS simulator uses real patient images, and is able to provide simulation for 50 cases, with a haptic interface that uses a standard TRUS probe and biopsy needle. Intrinsic reliability was successfully demonstrated by comparing results from the left and right sides of the prostate. Face and content validity respondents noted the realism of the simulator, and its appropriateness as a teaching model. The simulator was able to distinguish between experts and novices during construct validity testing. Conclusions: A virtual reality TRUS simulator has successfully been created. It has promising face, content and construct validity results.
引用
收藏
页码:19 / 26
页数:8
相关论文
共 50 条
  • [31] Is Gleason score in transrectal ultrasound guided prostate biopsy consistent with Gleason score in radical prostatectomy?
    Karabicak, Mustafa
    Turk, Hakan
    Ergani, Batuhan
    Kozacioglu, Zafer
    Koc, Gokhan
    Ilbey, Yusuf Ozlem
    KUWAIT MEDICAL JOURNAL, 2021, 53 (02): : 145 - 149
  • [32] Evaluation of targeted antimicrobial prophylaxis for transrectal ultrasound guided prostate biopsy: a prospective cohort trial
    Zembower, Teresa R.
    Maxwell, Kelly M.
    Nadler, Robert B.
    Cashy, John
    Scheetz, Marc H.
    Qi, Chao
    Schaeffer, Anthony J.
    BMC INFECTIOUS DISEASES, 2017, 17
  • [33] Evaluation of targeted antimicrobial prophylaxis for transrectal ultrasound guided prostate biopsy: a prospective cohort trial
    Teresa R. Zembower
    Kelly M. Maxwell
    Robert B. Nadler
    John Cashy
    Marc H. Scheetz
    Chao Qi
    Anthony J. Schaeffer
    BMC Infectious Diseases, 17
  • [34] Association of Warmer Weather and Infectious Complications Following Transrectal Ultrasound-Guided Prostate Biopsy
    Chen, Yu-Chen
    Chen, Hao-Wei
    Huang, Shu-Pin
    Lin, Szu-Huai
    Chu, Ting-Yin
    Li, Ching-Chia
    Juan, Yung-Shun
    Wu, Wen-Jeng
    JOURNAL OF PERSONALIZED MEDICINE, 2022, 12 (03):
  • [35] Variation of urinary PCA3 following transrectal ultrasound-guided prostate biopsy
    Prezelin, Y.
    Ronsin, C.
    Celhay, O.
    Pires, C.
    Dore, B.
    Fromont, G.
    Larre, S.
    Irani, J.
    PROGRES EN UROLOGIE, 2011, 21 (06): : 412 - 416
  • [36] Development and evaluation of a simulator for training of ultrasound-assisted transrectal gynecological examination of cattle
    Brombacher-Steiert, Silja
    Gundelach, Yasmin
    Heppelmann, Maike
    Debertolis, Letizia
    Tipold, Andrea
    Wissing, Sandra
    BERLINER UND MUNCHENER TIERARZTLICHE WOCHENSCHRIFT, 2021, 134
  • [37] Face, content and construct validation of the first virtual reality laparoscopic nephrectomy simulator
    Brewin, James
    Nedas, Tim
    Challacombe, Ben
    Elhage, Oussama
    Keisu, Jonas
    Dasgupta, Prokar
    BJU INTERNATIONAL, 2010, 106 (06) : 850 - 854
  • [38] Can we detect index tumor using transrectal ultrasound-guided prostate biopsy?
    Karabicak, Mustafa
    Turk, Hakan
    Ergani, Batuhan
    Kozacioglu, Zafer
    Koc, Gokhan
    Ilbey, Yusuf Ozlem
    KUWAIT MEDICAL JOURNAL, 2021, 53 (02): : 136 - 139
  • [39] Development and usability of a virtual reality umbilical venous catheter placement simulator
    Gohman, Taylor
    Nisar, Harris
    Gupta, Avinash
    Javed, M. Jawad
    Rau, Nicole
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2024, 19 (05) : 881 - 889
  • [40] A Virtual Reality Simulator for Basketball Free-Throw Skills Development
    Covaci, Alexandra
    Postelnicu, Cristian-Cezar
    Panfir, Alina Ninett
    Talaba, Doru
    TECHNOLOGICAL INNOVATION FOR VALUE CREATION, 2012, 372 : 105 - +