Development and validation of a virtual reality transrectal ultrasound guided prostatic biopsy simulator

被引:22
|
作者
Chalasani, Venu [1 ,2 ,3 ,4 ]
Cool, Derek W. [5 ]
Sherebrin, Shi [5 ]
Fenster, Aaron [5 ]
Chin, Joseph [1 ,2 ,3 ,4 ]
Izawa, Jonathan I. [1 ,2 ,3 ,4 ]
机构
[1] Univ Western Ontario, Dept Surg, Div Urol, Schulich Sch Med & Dent, London, ON N6A 3K7, Canada
[2] Univ Western Ontario, Dept Surg, Div Surg Oncol, Schulich Sch Med & Dent, London, ON N6A 3K7, Canada
[3] Univ Western Ontario, Dept Oncol, Div Urol, Schulich Sch Med & Dent, London, ON N6A 3K7, Canada
[4] Univ Western Ontario, Dept Oncol, Div Surg Oncol, Schulich Sch Med & Dent, London, ON N6A 3K7, Canada
[5] Univ Western Ontario, Robarts Res Inst, London, ON, Canada
来源
CUAJ-CANADIAN UROLOGICAL ASSOCIATION JOURNAL | 2011年 / 5卷 / 01期
关键词
CANCER; SYSTEM; UROLOGY; SEXTANT; SKILLS;
D O I
10.5489/cuaj.09159
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Objective: We present the design, reliability, face, content and construct validity testing of a virtual reality simulator for transrectal ultrasound (TRUS), which allows doctors-in-training to perform multiple different biopsy schemes. Methods: This biopsy system design uses a regular "end-firing" TRUS probe. Movements of the probe are tracked with a micro-magnetic sensor to dynamically slice through a phantom patient's 3D prostate volume to provide real-time continuous TRUS views. 3D TRUS scans during prostate biopsy clinics were recorded. Intrinsic reliability was assessed by comparing the left side of the prostate to the right side of the prostate for each biopsy. A content and face validity questionnaire was administered to 26 doctors to assess the simulator. Construct validity was assessed by comparing notes from experts and novices with regards to the time taken and the accuracy of each biopsy. Results: Imaging data from 50 patients were integrated into the simulator. The completed VR TRUS simulator uses real patient images, and is able to provide simulation for 50 cases, with a haptic interface that uses a standard TRUS probe and biopsy needle. Intrinsic reliability was successfully demonstrated by comparing results from the left and right sides of the prostate. Face and content validity respondents noted the realism of the simulator, and its appropriateness as a teaching model. The simulator was able to distinguish between experts and novices during construct validity testing. Conclusions: A virtual reality TRUS simulator has successfully been created. It has promising face, content and construct validity results.
引用
收藏
页码:19 / 26
页数:8
相关论文
共 50 条
  • [1] Robotic Transrectal Ultrasound Guided Prostate Biopsy
    Lim, Sunghwan
    Jun, Changhan
    Chang, Doyoung
    Petrisor, Doru
    Han, Misop
    Stoianovici, Dan
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2019, 66 (09) : 2527 - 2537
  • [2] Prostatic ductal adenocarcinoma: An aggressive variant that is underdiagnosed and undersampled on transrectal ultrasound (TRUS)-guided needle biopsy
    Gulavita, Previn
    Hakim, Shaheed W.
    Schieda, Nicola
    Breau, Rodney H.
    Morash, Chris
    Keefe, Daniel T.
    Robertson, Susan J.
    Mai, Kien T.
    Belanger, Eric C.
    Flood, Trevor A.
    CUAJ-CANADIAN UROLOGICAL ASSOCIATION JOURNAL, 2015, 9 (9-10): : 302 - 306
  • [3] The Efficacy of Transrectal Ultrasound Guided Biopsy Versus Transperineal Template Biopsy of the Prostate in Diagnosing Prostate Cancer in Men with Previous Negative Transrectal Ultrasound Guided Biopsy
    Nafie, Shady
    Wanis, Michael
    Khan, Masood
    UROLOGY JOURNAL, 2017, 14 (02) : 3008 - 3012
  • [4] Transrectal ultrasound-guided biopsy sepsis and the rise in carbapenem antibiotic use
    Leahy, Olivia R.
    O'Reilly, Mary
    Dyer, David R.
    Phillips, David
    Grummet, Jeremy P.
    ANZ JOURNAL OF SURGERY, 2015, 85 (12) : 931 - 935
  • [5] Validation of a Novel Virtual Reality Robotic Simulator
    Sethi, Amanjot S.
    Peine, William J.
    Mohammadi, Yousef
    Sundaram, Chandru P.
    JOURNAL OF ENDOUROLOGY, 2009, 23 (03) : 503 - 508
  • [6] Geometric Evaluation of Systematic Transrectal Ultrasound Guided Prostate Biopsy
    Han, Misop
    Chang, Doyoung
    Kim, Chunwoo
    Lee, Brian J.
    Zuo, Yihe
    Kim, Hyung-Joo
    Petrisor, Doru
    Trock, Bruce
    Partin, Alan W.
    Rodriguez, Ronald
    Carter, H. Ballentine
    Allaf, Mohamad
    Kim, Jongwon
    Stoianovici, Dan
    JOURNAL OF UROLOGY, 2012, 188 (06) : 2404 - 2409
  • [7] The change in serum Thiol/Disulphide homeostasis after transrectal ultrasound guided prostate biopsy
    Tokgoz, Husnu
    Tas, Selim
    Giray, Ozlem
    Yalcinkaya, Soner
    Tokgoz, Ozlem
    Koca, Cemile
    Savas, Murat
    Erel, Ozcan
    INTERNATIONAL BRAZ J UROL, 2017, 43 (03): : 455 - 461
  • [8] Validation of Simendo Knee Arthroscopy Virtual Reality Simulator
    van der Heijden, Laura L. M.
    Reijman, Max
    van der Steen, M. C.
    Janssen, Rob P. A.
    Tuijthof, Gabrielle J. M.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2019, 35 (08) : 2385 - 2390
  • [9] Improving the Gleason grading accuracy of transrectal ultrasound-guided biopsy
    Luisa Nieto-Morales, Maria
    Fernandez-Ramos, Julian
    Perez-Mendez, Lina
    Alventosa-Fernandez, Elena
    Soledad Pastor-Santovena, Maria
    Arias-Rodriguez, Angeles
    Aguirre-Jaime, Armando
    ACTA RADIOLOGICA, 2013, 54 (10) : 1218 - 1223
  • [10] Re: Geometric Evaluation of Systematic Transrectal Ultrasound Guided Prostate Biopsy
    Donaldson, I. A.
    Moore, C. M.
    Emberton, M.
    Ahmed, H. U.
    JOURNAL OF UROLOGY, 2013, 190 (01) : 363 - 364