A miniature CuO nanoarray sensor for noninvasive detection of trace salivary glucose

被引:10
|
作者
Yang, Jianping [1 ]
Chen, Huaying [1 ]
Zhu, Caijun [1 ]
Huang, Zhixuan [1 ]
Ou, Rufang [1 ]
Gao, Sijing [1 ]
Yang, Zhiqing [1 ]
机构
[1] Guangdong Univ Educ, Sch Chem & Mat Sci, Guangzhou 510303, Peoples R China
关键词
Miniature sensor; Noninvasive determination; CuO nanoarray; Trace glucose; Saliva; NANOWIRE ARRAYS; COPPER; ELECTRODES; BIOSENSOR; OXIDE; FOIL;
D O I
10.1016/j.ab.2022.114857
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An ultrasensitive mini-sensor has been developed for nonenzymatic and noninvasive determination of trace glucose in saliva. The miniature detector exhibits ultra-high sensitivity and resolution at very low glucose concentration owing to the excellent electrocatalytic activity and electron transfer rate of the prepared 3D ordered CuO nanoflake array in-situ grown on a copper foil. The structure and morphology of the cupric oxide nanoarray were characterized by X-ray powder diffraction and scanning electron microscopy. The electrocatalysis of the CuO nanoarray modified electrode to glucose was demonstrated by cyclic voltammetry and chronoamperometry. The modified electrode presents a high sensitivity of 4954 mu A mM(-1) cm(-2) to glucose at + 0.55 V with a wide linear range of 1.0 mu mol/L to 6000 mu mol/L and a low detection limit of 0.1 mu mol/L and longterm stability. Furthermore, the mini-sensor can clearly distinguish diabetics from healthy people because of its excellent sensing performance. The developed miniaturized sensor holds the prospect for noninvasive determination of trace glucose in saliva for diabetic patients.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Fabrication of hybrid CuO/Pt/Si nanoarray for non-enzymatic glucose sensing
    Liu, Zhaona
    Yadian, Boluo
    Liu, Hai
    Liu, Chao
    Zhang, Bowei
    Ramanujan, R. V.
    Huang, Yizhong
    ELECTROCHEMISTRY COMMUNICATIONS, 2013, 33 : 138 - 141
  • [2] Non-enzymatic salivary glucose detection using porous CuO nanostructures
    Chakraborty, Pinak
    Dhar, Saurab
    Deka, Nitumoni
    Debnath, Kamalesh
    Mondal, Suvra Prakash
    SENSORS AND ACTUATORS B-CHEMICAL, 2020, 302
  • [3] Salivary glucose detection based on platinum metal hydrogel prepared mouthguard electrochemical sensor
    Lu, Dingxi
    Li, Haotian
    Xiao, Nan
    Jiang, Mengyi
    Zuna, Yeerkentai
    Feng, Shiqin
    Li, Zhanhong
    Long, Jianjun
    Marty, Jean Louis
    Zhu, Zhigang
    TALANTA, 2025, 283
  • [4] Wearable hydrogel patch with noninvasive, electrochemical glucose sensor for natural sweat detection
    Lin, Pei-Heng
    Sheu, Sian-Chen
    Chen, Chien-Wei
    Huang, Sheng-Cih
    Li, Bor-Ran
    TALANTA, 2022, 241
  • [5] A planar microwave sensor for noninvasive detection of glucose concentration using regression analysis
    Singh, Tilakdhari
    Mishra, Piyush Kumar
    Pal, Aditya
    Tripathi, Vijay Shanker
    INTERNATIONAL JOURNAL OF MICROWAVE AND WIRELESS TECHNOLOGIES, 2023, 15 (08) : 1343 - 1353
  • [6] Nonenzymatic glucose sensor based on CuO microfibers composed of CuO nanoparticles
    Cao, Fei
    Gong, Jian
    ANALYTICA CHIMICA ACTA, 2012, 723 : 39 - 44
  • [7] Salivary Glucose Detection with Laser Induced Graphene/AgNPs Non-Enzymatic Sensor
    Aparicio-Martinez, Eider Pedro
    Vega-Rios, Alejandro
    Osuna, Velia
    Dominguez, Rocio Berenice
    BIOSENSORS-BASEL, 2023, 13 (02):
  • [8] Co3O4 Nanoparticles as a Noninvasive Electrochemical Sensor for Glucose Detection in Saliva
    Wang, Mei
    Liu, Fang
    Zhang, Zhifeng
    Meng, Erchao
    Gong, Feilong
    Li, Feng
    NANO, 2021, 16 (01)
  • [9] Electrocatalytic CuBr@CuO nanoparticles based salivary glucose probes
    Lin, Wei-Jan
    Lin, Yu-Syuan
    Chang, Huan-Tsung
    Unnikrishnan, Binesh
    Huang, Chih-Ching
    BIOSENSORS & BIOELECTRONICS, 2021, 194
  • [10] Sweat Glucose Sensor With SPCE Modified by CuO Nanorods
    Sathitaphiwan, Kittipat
    Auewetchanichkul, Natchanon
    Kaewparadai, Thitasiree
    Limwathanagura, Siwagorn
    Wanotayan, Sittinadh
    Pungetmongkol, Porpin
    IEEE SENSORS LETTERS, 2024, 8 (05)