Elevational Synthetic Aperture Focusing for Three-Dimensional Photoacoustic Imaging Using a Clinical One-Dimensional Array Transducer

被引:10
|
作者
Yoon, Changhan [1 ]
Kang, Jeeun [2 ]
Song, Tai-Kyong [3 ]
Chang, Jin Ho [4 ]
机构
[1] Inje Univ, Dept Biomed Engn, Gimhae, South Korea
[2] Johns Hopkins Univ, Whiting Sch Engn, Baltimore, MD 21218 USA
[3] Sogang Univ, Dept Elect Engn, Seoul, South Korea
[4] Daegu Gyeongbuk Inst Sci & Technol DGIST, Dept Elect Engn & Comp Sci, Daegu 42988, South Korea
基金
美国国家卫生研究院; 新加坡国家研究基金会;
关键词
Transducers; Imaging; Focusing; Three-dimensional displays; Apertures; Lenses; Acoustics; Photoacoustic; 1D array transducer; 3D imaging; breast cancer; synthetic aperture; ULTRASOUND; MICROSCOPY; COHERENCE; TOMOGRAPHY; DETECTOR;
D O I
10.1109/TBME.2022.3154754
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: Two-dimensional (2D) photoacoustic (PA) imaging based on array transducers provide high spatial resolution in the lateral direction by adopting receive dynamic focusing. However, the quality of PA image is often deteriorated by poor elevational resolution which is achieved by an acoustic lens. To overcome this limitation, we present a three-dimensional (3D) image reconstruction method using a commercial one-dimensional (1D) array transducer. Methods: In the method, the elevational resolution is improved by applying synthetic aperture focusing (SAF) technique along the elevational direction. For this, a commercially available 1D array transducer with an acoustic lens is modeled and appropriate synthetic focusing delay that can minimize the effect of the acoustic lens is derived by mathematical analysis. Results: From the simulation and experiment results, it was demonstrated that the proposed method can enhance the image quality of PA imaging, i.e., elevational resolution and signal-to-noise ratio (SNR). Conclusion: 3D PA images with improved elevational resolution were achieved using a clinical 1D array transducer. Significance: The presented method may be useful for clinical application such as detecting microcalcification, imaging of tumor vasculature and guidance of biopsy in real time.
引用
收藏
页码:2817 / 2825
页数:9
相关论文
共 50 条
  • [31] In vivo three-dimensional photoacoustic imaging based on a clinical matrix array ultrasound probe
    Wang, Yu
    Erpelding, Todd N.
    Jankovic, Ladislav
    Guo, Zijian
    Robert, Jean-Luc
    David, Guillaume
    Wang, Lihong V.
    JOURNAL OF BIOMEDICAL OPTICS, 2012, 17 (06)
  • [32] Three-dimensional differential interference contrast microscopy using synthetic aperture imaging
    Kim, Moonseok
    Choi, Youngwoon
    Fang-Yen, Christopher
    Sung, Yongjin
    Kim, Kwanhyung
    Dasari, Ramachandra R.
    Feld, Michael S.
    Choi, Wonshik
    JOURNAL OF BIOMEDICAL OPTICS, 2012, 17 (02)
  • [33] Synthetic aperture radar three-dimensional imaging ——From TomoSAR and array InSAR to microwave vision
    Ding C.
    Qiu X.
    Xu F.
    Liang X.
    Jiao Z.
    Zhang F.
    Journal of Radars, 2019, 8 (06):
  • [34] 3-DIMENSIONAL IMAGING BY SYNTHETIC-APERTURE FOCUSING TECHNIQUE USING A LARGE-APERTURE PLANE ULTRASONIC TRANSDUCER
    KIKUCHI, T
    SATO, S
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1993, 32 (5B): : 2513 - 2520
  • [35] Cylindrical aperture three-dimensional synthetic aperture imaging with pulsed terahertz waves
    Du, Yuanhao
    Feng, Hui
    Wu, Shuai
    OPTICS EXPRESS, 2024, 32 (23): : 40190 - 40201
  • [36] Three-dimensional synthetic aperture focusing photoacoustic microscopy based on the acoustic simulation generated delay time and weighted factor
    Peng, Kuan
    Pang, Weiran
    Xiao, Jiaying
    Wang, Bo
    Zhang, Xiaokai
    APPLIED OPTICS, 2020, 59 (32) : 10082 - 10092
  • [37] Three-dimensional ghost imaging using acoustic transducer
    Zhang, Chi
    Guo, Shuxu
    Guan, Jian
    Cao, Junsheng
    Gao, Fengli
    OPTICS COMMUNICATIONS, 2016, 368 : 134 - 140
  • [38] Three-dimensional print using a one-dimensional screen technique
    Sakamoto, Sho
    Takaki, Yasuhiro
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2008, 47 (07) : 5486 - 5492
  • [39] Three-dimensional print using a one-dimensional screen technique
    Sakamoto, Sho
    Takaki, Yasuhiro
    Japanese Journal of Applied Physics, 2008, 47 (7 PART 1): : 5486 - 5492
  • [40] Three-Dimensional Ultrasound Molecular Imaging of Angiogenesis in Colon Cancer Using a Clinical Matrix Array Ultrasound Transducer
    Wang, Huaijun
    Kaneko, Osamu F.
    Tian, Lu
    Hristov, Dimitre
    Willmann, Juergen K.
    INVESTIGATIVE RADIOLOGY, 2015, 50 (05) : 322 - 329