Radiation risk issues in recurrent imaging

被引:48
作者
Brower, Charles [1 ]
Rehani, Madan M. [2 ]
机构
[1] Harvard Med Sch, Boston, MA 02115 USA
[2] Massachusetts Gen Hosp, Boston, MA 02114 USA
关键词
EMERGENCY-DEPARTMENT PATIENTS; INFLAMMATORY-BOWEL-DISEASE; DOSE IONIZING-RADIATION; COMPUTED-TOMOGRAPHY; SKIN INJURIES; CANCER-RISKS; EXPOSURE; CT; PROTECTION; TRENDS;
D O I
10.1259/bjr.20210389
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Millions of patients benefit from medical imaging every single day. However, we have entered an unprecedented era in imaging practices wherein 1 out of 125 patients can be exposed to effective dose >50 mSv from a single CT exam and 3 out of 10,000 patients undergoing CT exams could potentially receive cumulative effective doses > 100 mSv in a single day. Recurrent imaging with CT, fluoroscopically guided interventions, and hybrid imaging modalities such as positron emission tomography/computed tomography (PET/CT) is more prevalent today than ever before. Presently, we do not know the cumulative doses that patients may be receiving across all imaging modalities combined. Furthermore, patients with diseases with longer life expectancies are being exposed to high doses of radiation enabling radiation effects to manifest over a longer time period. The emphasis in the past on improving justification of imaging and optimization of technique and practice has proved useful. While that must continue, the current situation requires imaging device manufacturers to urgently develop imaging technologies that are safer for patients as high doses have been observed in patients where imaging has been justified through clinical decision-support and optimized by keeping doses below the national benchmark doses. There is a need to have a critical look at the fundamental principles of radiation protection as cumulative doses are likely to increase in the coming years.
引用
收藏
页数:10
相关论文
共 116 条
[1]  
An initiative of ABIM Foundation, 2021, CHOOS WISELY
[2]   Analysis of patients receiving ≥ 100 mSv during a computed tomography intervention [J].
Arellano, Ronald S. ;
Yang, Kai ;
Rehani, Madan M. .
EUROPEAN RADIOLOGY, 2021, 31 (05) :3065-3070
[3]   REJECT ANALYSIS - A PILOT PROGRAM FOR IMAGE QUALITY MANAGEMENT [J].
ARVANITIS, TN ;
PARIZEL, PM ;
DEGRYSE, HR ;
DESCHEPPER, AMA .
EUROPEAN JOURNAL OF RADIOLOGY, 1991, 12 (03) :171-176
[4]   Unintentional exposure of neonates to conventional radiography in the Neonatal Intensive Care Units [J].
Bader, D. ;
Datz, H. ;
Bartal, G. ;
Juster, A. A. ;
Marks, K. ;
Smolkin, T. ;
Zangen, S. ;
Kugelman, A. ;
Hoffmann, C. ;
Shani, G. ;
Ben-Shlomo, A. ;
Margaliot, M. ;
Sadetzki, S. .
JOURNAL OF PERINATOLOGY, 2007, 27 (09) :579-585
[5]   Multinational data on cumulative radiation exposure of patients from recurrent radiological procedures: call for action [J].
Brambilla, Marco ;
Vassileva, Jenia ;
Kuchcinska, Agnieszka ;
Rehani, Madan M. .
EUROPEAN RADIOLOGY, 2020, 30 (05) :2493-2501
[6]   Cumulative radiation dose and radiation risk from medical imaging in patients subjected to endovascular aortic aneurysm repair [J].
Brambilla, Marco ;
Cerini, Paolo ;
Lizio, Domenico ;
Vigna, Luca ;
Carriero, Alessandro ;
Fossaceca, Rita .
RADIOLOGIA MEDICA, 2015, 120 (06) :563-570
[7]   Estimating cancer risks from pediatric CT: going from the qualitative to the quantitative [J].
Brenner, DJ .
PEDIATRIC RADIOLOGY, 2002, 32 (04) :228-231
[8]   Cumulative CT exposures in emergency department patients evaluated for suspected renal colic [J].
Broder, Joshua ;
Bowen, Josie ;
Lohr, Jeffrey ;
Babcock, Andrew ;
Yoon, Jungyeon .
JOURNAL OF EMERGENCY MEDICINE, 2007, 33 (02) :161-168
[9]   Radiation exposure in patients with inflammatory bowel disease-primum non nocere? [J].
Butcher, Rhys Owain ;
Nixon, Emma ;
Sapundzieski, Milan ;
Filobbos, Rafik ;
Limdi, Jimmy K. .
SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 2012, 47 (10) :1192-1199
[10]   Mechanical obstruction of the small bowel and colon [J].
Cappell, Mitchell S. ;
Batke, Mihaela .