Diagnostic accuracy of computed tomography colonography in patients at high risk for colorectal cancer: a meta-analysis

被引:4
作者
Bai, W. [1 ]
Yu, D. [2 ]
Zhu, B. [1 ]
Yu, X. [1 ]
Duan, R. [1 ]
Li, Y. [1 ]
Yu, W. [1 ]
Hua, W. [1 ]
Kou, C. [1 ]
机构
[1] Jilin Univ, Sch Publ Hlth, Dept Epidemiol & Biostat, 1163 Xinmin St, Changchun 130021, Jilin, Peoples R China
[2] Fifth Peoples Hosp Shenyang, Dept Surg Oncol, Shenyang, Peoples R China
关键词
colorectal cancer; computed tomography colonography; meta-analysis; CT-COLONOGRAPHY; VIRTUAL COLONOSCOPY; POPULATION; NEOPLASIA; PERFORMANCE; ACCEPTABILITY; INDIVIDUALS; MULTICENTER; ACCEPTANCE; ADENOMAS;
D O I
10.1111/codi.15060
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Aim The aim was to explore the diagnostic value of computed tomographic colonography (CTC) compared with conventional colonoscopy in individuals at high risk for colorectal cancer. Method PubMed, Embase, the Cochrane Library and the Web of Science were searched by two independent reviewers for potentially eligible studies published up to 31 October 2018 that were based on a per-patient analysis. stata, meta-disc and revman were used to perform this meta-analysis. A random-effect model was used, and a subgroup analysis was conducted to explore the sources of heterogeneity. Results A total of 14 full-text articles, involving 3578 patients, were included in this meta-analysis. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio and the area under the summary receiver operating characteristic curve of CTC for detecting polyps >= 6 mm were 0.87 (95% CI 0.83-0.90), 0.90 (95% CI 0.86-0.93), 9.08 (95% CI 6.28-13.13), 0.14 (95% CI 0.11-0.18) and 0.94 (95% CI 0.92-0.96), respectively. For polyps >= 10 mm, the pooled sensitivity, specificity, positive likelihood ratio and negative likelihood ratio of CTC were 0.91 (95% CI 0.86-0.94), 0.98 (95% CI 0.95-0.99), 40.36 (95% CI 19.16-85.03), 0.90 (95% CI 0.06-0.14) and 0.98 (95% CI 0.96-0.99), respectively. Conclusion In this meta-analysis, CTC had high diagnostic accuracy for detecting polyps >= 6 mm and >= 10 mm in patients at high risk of developing colorectal cancer and it had a higher sensitivity and specificity for detecting polyps >= 10 mm than polyps >= 6 mm. However, the results should be used cautiously due to the significant heterogeneity.
引用
收藏
页码:1538 / 1544
页数:7
相关论文
共 32 条
[1]   Colon distension and scan protocol for CT-colonography: An overview [J].
Boellaard, Thierry N. ;
de Haan, Margriet C. ;
Venema, Henk W. ;
Stoker, Jaap .
EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (08) :1144-1158
[2]   Risk of Colorectal Cancer After Detection and Removal of Adenomas at Colonoscopy: Population-Based Case-Control Study [J].
Brenner, Hermann ;
Chang-Claude, Jenny ;
Rickert, Alexander ;
Seiler, Christoph M. ;
Hoffmeister, Michael .
JOURNAL OF CLINICAL ONCOLOGY, 2012, 30 (24) :2969-2976
[3]   Protection From Colorectal Cancer After Colonoscopy A Population-Based, Case-Control Study [J].
Brenner, Hermann ;
Chang-Claude, Jenny ;
Seiler, Christoph M. ;
Rickert, Alexander ;
Hoffmeister, Michael .
ANNALS OF INTERNAL MEDICINE, 2011, 154 (01) :22-U156
[4]   Low adherence to colonoscopy in the screening of first-degree relatives of patients with colorectal cancer [J].
Bujanda, Luis ;
Sarasqueta, Cristina ;
Zubiaurre, Leire ;
Cosme, Angel ;
Munoz, Carmen ;
Sanchez, Araceli ;
Martin, Cristina ;
Tito, Llucia ;
Pinol, Virginia ;
Castells, Antoni ;
Llor, Xavier ;
Xicola, Rosa M. ;
Pons, Elisenda ;
Clofent, Juan ;
de Castro, Maria L. ;
Cuquerella, Jaime ;
Medina, Enrique ;
Gutierrez, Ana ;
Arenas, Juan I. ;
Jover, Rodrigo .
GUT, 2007, 56 (12) :1714-1718
[5]  
Chaparro Sanchez Maria, 2007, Gastroenterol Hepatol, V30, P375
[6]   Diagnostic value of CT-colonography as compared to colonoscopy in an asymptomatic screening population: a meta-analysis [J].
de Haan, Margriet C. ;
van Gelder, Rogier E. ;
Graser, Anno ;
Bipat, Shandra ;
Stoker, Jaap .
EUROPEAN RADIOLOGY, 2011, 21 (08) :1747-1763
[7]   Primary uncleansed 2D versus primary electronically cleansed 3D in limited bowel preparation CT-colonography. Is there a difference for novices and experienced readers? [J].
de Vries, Ayso H. ;
Liedenbaum, Marjolein H. ;
Bipat, Shandra ;
Truyen, Roel ;
Serlie, Iwo W. O. ;
Cohen, Rutger H. ;
van Elderen, Saskia G. C. ;
Heutinck, Anneke ;
Kesselring, Oskar ;
de Monye, Wouter ;
te Strake, Lambertus ;
Wiersma, Tjeerd ;
Stoker, Jaap .
EUROPEAN RADIOLOGY, 2009, 19 (08) :1939-1950
[8]   Worldwide burden of colorectal cancer: a review [J].
Favoriti, Pasqualino ;
Carbone, Gabriele ;
Greco, Marco ;
Pirozzi, Felice ;
Pirozzi, Raffaele Emmanuele Maria ;
Corcione, Francesco .
UPDATES IN SURGERY, 2016, 68 (01) :7-11
[9]   Primary Three-Dimensional Analysis with Perspective-Filet View Versus Primary Two-Dimensional Analysis: Evaluation of Lesion Detection by Inexperienced Readers at Computed Tomographic Colonography in Symptomatic Patients [J].
Fisichella, V. A. ;
Jaderling, F. ;
Horvath, S. ;
Stotzer, P. -O. ;
Kilander, A. ;
Hellstrom, M. .
ACTA RADIOLOGICA, 2009, 50 (03) :244-255
[10]   Accuracy of computed tomographic colonography in a nationwide multicentre trial, and its relation to radiologist expertise [J].
Heresbach, D. ;
Djabbari, M. ;
Riou, F. ;
Marcus, C. ;
Le Sidaner, A. ;
Pierredon-Foulogne, M. A. ;
Ponchon, T. ;
Boudiaf, M. ;
Seyrig, J. A. ;
Laumonier, H. ;
Luet, D. ;
Giraud-Cohen, M. ;
Pelletier, A. L. ;
Charachon, A. ;
Ramaholimihaso, F. ;
Bouillet, P. ;
Veyrac, M. ;
Ficarelli, S. ;
Vahedi, K. ;
Keruhel, J. ;
Lamouliatte, H. ;
Ridereau-Zins, C. ;
Bouhnik, Y. ;
Tissier, M. ;
Diris, B. ;
Zagdanski, A. M. ;
Josselin, J. M. ;
Hamonic, S. ;
Gandon, Y. ;
Ganivet, Anne ;
Pilleul, Franck ;
Poupeney, Severine ;
Burtin, Pascal ;
Barrau, Vincent ;
Vallot, Thierry ;
Subtil, Clement ;
Simon, Marion ;
De Bazelaire, Cedric ;
Gornet, Jean Marc ;
Sellier, Nicolas ;
Beaugrand, Michel ;
Maitre, Sophie ;
Asnacios, Amani ;
Bessoud, Bertrand ;
Rangheard, Anne-Sophie ;
Boytchev, Isabelle ;
Siauve, Nathalie ;
Bloch, Francis ;
Belkacem, Achene ;
Coffin, Benoit .
GUT, 2011, 60 (05) :658-665