One-stop preoperative assessment of renal vessels for living donors with 3.0 T non-contrast-enhanced magnetic resonance angiography: compared with computerized tomography angiography and surgical results

被引:6
作者
Li, Xiaotian [1 ]
Xia, Fangjie [2 ]
Chen, Lihua [3 ]
Zhang, Xiaodong [3 ]
Mo, Chunbai [4 ]
Shen, Wen [3 ]
机构
[1] Nankai Univ, Sch Med, Tianjin, Peoples R China
[2] Tianjin Med Univ, Tianjin Ctr Hosp 1, Dept Radiol, Tianjin, Peoples R China
[3] Nankai Univ, Tianjin Ctr Hosp 1, Sch Med, Dept Radiol, Tianjin, Peoples R China
[4] Nankai Univ, Tianjin Ctr Hosp 1, Sch Med, Dept Kidney Transplantat, Tianjin, Peoples R China
基金
美国国家科学基金会;
关键词
MR-ANGIOGRAPHY; LAPAROSCOPIC NEPHRECTOMY; TRANSPLANT DONORS; CT ANGIOGRAPHY; KIDNEY DONORS; ARTERIES; TESLA; RECONSTRUCTION; ALLOGRAFTS; RECIPIENTS;
D O I
10.1259/bjr.20210589
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The study was to investigate the feasibility and accuracy of assessment for living renal donors before transplantation by using 3.0 T non-contrast-enhanced magnetic resonance angiography (NCE-MRA). Methods: 30 renal donors were investigated and underwent computed tomography angiography (CTA) and 3.0 T NCE-MRA before nephrectomy. Two radiologists independently assessed arterial and venous anatomy and potential kidney lesions. The image quality score, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), diameters and lengths of renal arteries and veins were compared between CTA and NCE-MRA. Imaging findings were compared with the surgical results served as reference standard. Agreement was assessed using kappa test. The Wilcoxon test and paired sample t test were used for statistically significant differences. Results: The results of image quality score for renal arteries and veins were highly consistent between the two radiologists in NCE-MRA (p < 0.001). There was no significant difference in the scores of renal arterial and venous branches between NCE-MRA and CTA (p > 0.05). The SNR and CNR of renal vessels were higher than CTA (p < 0.001). There were no statistically significant differences in the length of renal vessels measured by the two methods (p > 0.05), and the diameter was smaller than that of CTA (p < 0.05). The detection of normal renal arteries and early branches by both examination techniques was consistent with intraoperative findings. Both methods showed good consistency between the anatomical variation of renal vein and the intraoperative diagnosis (p < 0.001). Conclusion: 3.0 T NCE-MRA can be used for evaluation of main renal arteries and veins with high accuracy for anatomy and variation classification, and can be used for pre-operative vascular evaluation of living donor kidney transplantation. Advances in knowledge: 3.0 T NCE-MRA can be used for evaluation of main renal arteries and veins with high accuracy for anatomy and variation classification, and can be used for preoperative vascular evaluation of living donor kidney transplantation.
引用
收藏
页数:10
相关论文
共 32 条
[1]   Vascular imaging in renal donors [J].
Aghayev, Ayaz ;
Gupta, Sumit ;
Dabiri, Borna E. ;
Steigner, Michael L. .
CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2019, 9 :S116-S130
[2]   Gadolinium Distribution in Cerebrospinal Fluid after Administration of a Gadolinium-based MR Contrast Agent in Humans [J].
Berger, Florian ;
Kubik-Huch, Rahel A. ;
Niemann, Tilo ;
Schmid, Hans Ruedi ;
Poetzsch, Michael ;
Froehlich, Johannes M. ;
Beer, Jiirg H. ;
Thali, Michael J. ;
Kraemer, Thomas .
RADIOLOGY, 2018, 288 (03) :703-709
[3]   Noncontrast-Enhanced Magnetic Resonance Versus Computed Tomography Angiography in Preoperative Evaluation of Potential Living Renal Donors [J].
Blankholm, Anne Dorte ;
Pedersen, Bodil G. ;
Ostrat, Ernst O. ;
Andersen, Gratien ;
Stausbol-Gron, Brian ;
Laustsen, Susse ;
Ringgaard, Steffen .
ACADEMIC RADIOLOGY, 2015, 22 (11) :1368-1375
[4]   Non-contrast-enhanced MRA of renal artery stenosis: validation against DSA in a porcine model [J].
Bley, T. A. ;
Francois, C. J. ;
Schiebler, M. L. ;
Wieben, O. ;
Takei, N. ;
Brittain, J. H. ;
Del Rio, A. Munoz ;
Grist, T. M. ;
Reeder, S. B. .
EUROPEAN RADIOLOGY, 2016, 26 (02) :547-555
[5]   Pre-operative assessment of living renal transplant donors with state-of-the-art imaging modalities: computed tomography angiography versus magnetic resonance angiography in 118 patients [J].
Engelken, F. ;
Friedersdorff, F. ;
Fuller, T. F. ;
Magheli, A. ;
Budde, K. ;
Halleck, F. ;
Deger, S. ;
Liefeldt, L. ;
Hamm, B. ;
Giessing, M. ;
Diederichs, G. .
WORLD JOURNAL OF UROLOGY, 2013, 31 (04) :983-990
[6]   Contrast-enhanced magnetic resonance angiography: evaluation of renal arteries in living renal transplant donors [J].
Firat, A ;
Akin, O ;
Agildere, AM ;
Aytekin, C ;
Haberal, M .
EUROPEAN JOURNAL OF RADIOLOGY, 2004, 52 (01) :84-93
[7]   Experience and Security of the Hand-Assisted Laparoscopic Nephrectomy of a Living Donor in a Public Health Center [J].
Garcia-Covarrubias, L. ;
Prieto-Olivares, P. ;
Bahena-Portillo, A. ;
Cicero-Lebrija, A. ;
Hinojosa-Heredia, H. ;
Fernandez-Lopez, L. J. ;
Almeida-Nieto, C. ;
Visag-Castillo, V. J. ;
Carrion-Barrera, J. ;
Castro-Nuco, I. ;
Pedraza-Rojas, E. ;
Rosas-Herrera, A. ;
Garcia-Covarrubias, A. ;
Fernandez-Angel, D. ;
Diliz-Perez, H. S. .
TRANSPLANTATION PROCEEDINGS, 2018, 50 (02) :433-435
[8]   Comparison of CT Angiography With MR Angiography in the Preoperative Assessment of Living Kidney Donors [J].
Gluecker, Thomas M. ;
Mayr, Michael ;
schwarz, Jochen ;
Bilecen, Deniz ;
Voegele, Thomas ;
Steiger, Juerg ;
Bachmann, Alexander ;
Bongartz, Georg .
TRANSPLANTATION, 2008, 86 (09) :1249-1256
[9]   Diagnostic Performance of a Non-Contrast-Enhanced Magnetic Resonance Imaging Protocol for Potential Living Related Kidney Donors [J].
Goetti, Robert ;
Baumueller, Stephan ;
Alkadhi, Hatem ;
Clavien, Pierre-Alain ;
Schiesser, Marc ;
Pfammatter, Thomas ;
Hunziker, Roger ;
Puippe, Gilbert .
ACADEMIC RADIOLOGY, 2013, 20 (04) :393-400
[10]   3.0 Tesla magnetic resonance angiography (MRA) for comprehensive renal evaluation of living renal donors: pilot study with computerized tomography angiography (CTA) comparison [J].
Gulati, Mittul ;
Dermendjian, Harout ;
Gomez, Ana M. ;
Tan, Nelly ;
Margolis, Daniel J. ;
Lu, David S. ;
Gritsch, H. Albin ;
Raman, Steven S. .
CLINICAL IMAGING, 2016, 40 (03) :370-377