Characteristic wavelength selection of volatile organic compounds infrared spectra based on improved interval partial least squares

被引:6
|
作者
Ju, Wei [1 ]
Lu, Changhua [1 ,2 ]
Zhang, Yujun [2 ]
Jiang, Weiwei [1 ]
Wang, Jizhou [1 ]
Lu, Yi Bing [2 ]
Hong, Feng [1 ]
机构
[1] Hefei Univ Technol, Sch Comp & Informat, Hefei 230009, Anhui, Peoples R China
[2] Chinese Acad Sci, Anhui Inst Opt Fine Mech, Hefei 230031, Anhui, Peoples R China
关键词
Ambient air monitoring; Fourier transform infrared spectra analysis; variable selection; interval partial least square; Monte-Carlo sampling; VARIABLE SELECTION; VOCS; SPECTROSCOPY; ELIMINATION; DEGRADATION; TEMPERATURE; REGRESSION; TRANSFORM; ALGORITHM; OXIDATION;
D O I
10.1142/S1793545819500056
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
As important components of air pollutant, volatile organic compounds (VOCs) can cause great harm to environment and human body. The concentration change of VOCs should be focused on in real-time environment monitoring system. In order to solve the problem of wavelength redundancy in full spectrum partial least squares (PLS) modeling for VOCs concentration analysis, a new method based on improved interval PLS (iPLS) integrated with Monte-Carlo sampling, called iPLS-MC method, was proposed to select optimal characteristic wavelengths of VOCs spectra. This method uses iPLS modeling to preselect the characteristic wavebands of the spectra and generates random wavelength combinations from the selected wavebands by Monte-Carlo sampling. The wavelength combination with the best prediction result in regression model is selected as the characteristic wavelengths of the spectrum. Different wavelength selection methods were built, respectively, on Fourier transform infrared (FTIR) spectra of ethylene and ethanol gas at different concentrations obtained in the laboratory. When the interval number of iPLS model is set to 30 and the Monte-Carlo sampling runs 1000 times, the characteristic wavelengths selected by iPLS-MC method can reduce from 8916 to 10, which occupies only 0.22% of the full spectrum wavelengths. While the RMSECV and correlation coefficient (Rc) for ethylene are 0.2977 and 0.9999 ppm, and those for ethanol gas are 0.2977 ppm and 0.9999. The experimental results show that the iPLS-MC method can select the optimal characteristic wavelengths of VOCs FTIR spectra stably and effectively, and the prediction performance of the regression model can be significantly improved and simplified by using characteristic wavelengths.
引用
收藏
页数:19
相关论文
共 50 条
  • [21] Optimisation of partial least squares regression calibration models in near-infrared spectroscopy: a novel algorithm for wavelength selection
    Smith, MR
    Jee, RD
    Moffat, AC
    Rees, DR
    Broad, NW
    ANALYST, 2003, 128 (11) : 1312 - 1319
  • [22] Wavelength Selection Method of Near-Infrared Spectrum Based on Random Forest Feature Importance and Interval Partial Least Square Method
    Chen, Rui
    Wang, Xue
    Wang Zi-wen
    Qu, Hao
    Ma Tie-min
    Chen Zheng-guang
    Gao, Rui
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43 (04) : 1043 - 1050
  • [23] Dual stacked partial least squares for analysis of near-infrared spectra
    Bi, Yiming
    Xie, Qiong
    Peng, Silong
    Tang, Liang
    Hu, Yong
    Tan, Jie
    Zhao, Yuhui
    Li, Changwen
    ANALYTICA CHIMICA ACTA, 2013, 792 : 19 - 27
  • [24] Infrared face recognition based on DCT and partial least squares
    Xie, Zhihua
    Liu, Guodong
    Communications in Computer and Information Science, 2014, 437 : 67 - 73
  • [25] MIDINFRARED SPECTRA FROM NEAR-INFRARED SPECTRA USING PARTIAL LEAST-SQUARES
    LEW, R
    BALKE, ST
    APPLIED SPECTROSCOPY, 1993, 47 (11) : 1747 - 1750
  • [26] A Partial Least Squares based algorithm for parsimonious variable selection
    Mehmood, Tahir
    Martens, Harald
    Saebo, Solve
    Warringer, Jonas
    Snipen, Lars
    ALGORITHMS FOR MOLECULAR BIOLOGY, 2011, 6
  • [27] Model selection for partial least squares based dimension reduction
    Li, Guo-Zheng
    Zhao, Rui-Wei
    Qu, Hai-Ni
    You, Mingyu
    PATTERN RECOGNITION LETTERS, 2012, 33 (05) : 524 - 529
  • [28] Investigation of partial least squares (PLS) calibration performance based on different resolutions of near infrared spectra
    Chung, H
    Choi, SY
    Choo, J
    Lee, Y
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2004, 25 (05): : 647 - 651
  • [29] Multiblock partial least squares regression based on wavelet transform for quantitative analysis of near infrared spectra
    Jing, Ming
    Cai, Wensheng
    Shao, Xueguang
    CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2010, 100 (01) : 22 - 27
  • [30] A Partial Least Squares based algorithm for parsimonious variable selection
    Tahir Mehmood
    Harald Martens
    Solve Sæbø
    Jonas Warringer
    Lars Snipen
    Algorithms for Molecular Biology, 6