Phantomless assessment of volumetric bone mineral density using virtual non-contrast images from spectral detector computed tomography

被引:14
作者
Zopfs, David [1 ,2 ]
Lennartz, Simon [1 ,2 ,3 ,4 ]
Zaeske, Charlotte [1 ,2 ]
Merkt, Martin [1 ,5 ]
Laukamp, Kai Roman [1 ,2 ]
Reimer, Robert Peter [1 ,2 ]
Maintz, David [1 ,2 ]
Borggrefe, Jan [1 ,2 ]
Hokamp, Nils Grosse [1 ,2 ]
机构
[1] Univ Cologne, Fac Med, Cologne, Germany
[2] Univ Hosp Cologne, Inst Diagnost & Intervent Radiol, Cologne, Germany
[3] Univ Hosp Cologne, Else Kroner Forschungskolleg Clonal Evolut Canc, Weyertal 115b, D-50931 Cologne, Germany
[4] Massachusetts Gen Hosp, Dept Radiol, 55 Fruit St,White 270, Boston, MA 02114 USA
[5] Univ Hosp Cologne, Cologne, Germany
关键词
DUAL-ENERGY CT; DIAGNOSTIC-ACCURACY; OSTEOPOROSIS; PREVALENCE; METASTASES; FRACTURES;
D O I
10.1259/bjr.20190992
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To evaluate phantomless assessment of volumetric bone mineral density (vBMD) based on virtual non-contrast images of arterial (VNCa) and venous phase (VNCv) derived from spectral detector CT in comparison to true non-contrast (TNC) images and adjusted venous phase conventional images (CIV(adjusted)). Methods: 104 consecutive patients who underwent triphasic spectral detector CT between January 2018 and April 2019 were retrospectively included. TNC, VNCa, VNCv and venous phase images (CIV) were reconstructed. vBMD was obtained by two radiologists using an FDA/CE-cleared software. Average vBMD of the first three lumbar vertebrae was determined in each reconstruction; vBMD of CIV was adjusted for contrast enhancement as suggested earlier. Results: vBMD values obtained from CIV(adjusted) are comparable to vBMD values derived from TNC images (91.79 +/- 36.52 vs 90.16 +/- 41.71 mg/cm(3), p = 1.00); however, vBMD values derived from VNCa and VNCv (42.20 +/- 22.50 and 41.98 +/- 23.3 mg/cm(3) respectively) were significantly lower as compared to vBMD values from TNC and CIV(adjusted) (all p = 0.01). Conclusion: Spectral detector CT-derived virtual non-contrast images systematically underestimate vBMD and therefore should not be used without appropriate adjustments. Adjusted venous phase images provide reliable results and may be utilized for an opportunistic BMD screening in CT examinations. Advances in knowledge: Adjustments of venous phase images facilitate opportunistic assessment of vBMD, while spectral detector CT-derived VNC images systematically underestimate vBMD.
引用
收藏
页数:6
相关论文
共 35 条
[1]   Improvements of diagnostic accuracy and visualization of vertebral metastasis using multi-level virtual non-calcium reconstructions from dual-layer spectral detector computed tomography [J].
Abdullayev, N. ;
Hokamp, N. Grosse ;
Lennartz, S. ;
Holz, J. A. ;
Romman, Z. ;
Pahn, G. ;
Neuhaus, V ;
Maintz, D. ;
Krug, B. ;
Borggrefe, J. .
EUROPEAN RADIOLOGY, 2019, 29 (11) :5941-5949
[2]   Effects of Contrast Enhancement on In-Body Calibrated Phantomless Bone Mineral Density Measurements in Computed Tomography [J].
Abdullayev, Nuran ;
Neuhaus, Victor-Frederic ;
Bratke, Grischa ;
Voss, Sebastian ;
Hokamp, Nils Grosse ;
Hellmich, Martin ;
Krug, Barbara ;
Maintz, David ;
Borggrefe, Jan .
JOURNAL OF CLINICAL DENSITOMETRY, 2018, 21 (03) :360-366
[3]   Opportunistic screening for osteoporosis by routine CT in Southern Europe [J].
Alacreu, Elena ;
Moratal, David ;
Arana, Estanislao .
OSTEOPOROSIS INTERNATIONAL, 2017, 28 (03) :983-990
[4]   Spectral detector CT-derived virtual non-contrast images: comparison of attenuation values with unenhanced CT [J].
Ananthakrishnan, Lakshmi ;
Rajiah, Prabhakar ;
Ahn, Richard ;
Rassouli, Negin ;
Xi, Yin ;
Soesbe, Todd C. ;
Lewis, Matthew A. ;
Lenkinski, Robert E. ;
Leyendecker, John R. ;
Abbara, Suhny .
ABDOMINAL RADIOLOGY, 2017, 42 (03) :702-709
[5]   Utilization of virtual non-contrast images derived from dual-energy CT in evaluation of biliary stone disease: Virtual non-contrast image can replace true non-contrast image regarding biliary stone detection [J].
Bae, Jae Seok ;
Lee, Dong Ho ;
Joo, Ijin ;
Jeon, Sun Kyung ;
Han, Joon Koo .
EUROPEAN JOURNAL OF RADIOLOGY, 2019, 116 :34-40
[6]   DXA in vivo BMD methodology:: An erroneous and misleading research and clinical gauge of bone mineral status, bone fragility, and bone remodelling [J].
Bolotin, H. H. .
BONE, 2007, 41 (01) :138-154
[7]   Accuracy of iodine density thresholds for the separation of vertebral bone metastases from healthy-appearing trabecular bone in spectral detector computed tomography [J].
Borggrefe, Jan ;
Neuhaus, Victor-Frederic ;
Le Blanc, Markus ;
Hokamp, Nils Grosse ;
Maus, Volker ;
Mpotsaris, Anastasios ;
Lennartz, Simon ;
dos Santos, Daniel Pinto ;
Maintz, David ;
Abdullayev, Nuran .
EUROPEAN RADIOLOGY, 2019, 29 (06) :3253-3261
[8]   Diagnostic accuracy of virtual non-contrast enhanced dual-energy CT for diagnosis of adrenal adenoma: A systematic review and meta-analysis [J].
Connolly, Michael J. ;
McInnes, Matthew D. F. ;
El-Khodary, Mohamed ;
McGrath, Trevor A. ;
Schieda, Nicola .
EUROPEAN RADIOLOGY, 2017, 27 (10) :4324-4335
[9]   Longitudinal trends in use of bone mass measurement among older Americans, 1999-2005 [J].
Curtis, Jeffrey R. ;
Carbone, Laura ;
Cheng, Hong ;
Hayes, Burton ;
Laster, Andrew ;
Matthews, Robert ;
Saag, Kenneth G. ;
Sepanski, Robert ;
Tanner, Simpson B. ;
Delzell, Elizabeth .
JOURNAL OF BONE AND MINERAL RESEARCH, 2008, 23 (07) :1061-1067
[10]   Radiation exposure in X-ray-based imaging techniques used in osteoporosis [J].
Damilakis, John ;
Adams, Judith E. ;
Guglielmi, Giuseppe ;
Link, Thomas M. .
EUROPEAN RADIOLOGY, 2010, 20 (11) :2707-2714