Determination of optimal virtual monochromatic energy level for target delineation of brain metastases in radiosurgery using dual-energy CT

被引:8
|
作者
Karino, Tsukasa [1 ]
Ohira, Shingo [1 ,2 ]
Kanayama, Naoyuki [1 ]
Wada, Kentaro [1 ]
Ikawa, Toshiki [1 ]
Nitta, Yuya [1 ]
Washio, Hayate [1 ]
Miyazaki, Masayoshi [1 ,3 ]
Teshima, Teruki [1 ]
机构
[1] Osaka Int Canc Inst, Dept Radiat Oncol, Osaka, Japan
[2] Osaka Univ, Med, Dept Med Phys & Engn, Osaka, Japan
[3] Hyogo Coll Med, Dept Radiol, Nishinomiya, Hyogo, Japan
关键词
TUMOR VOLUME DELINEATION; COMPUTED-TOMOGRAPHY; MONOENERGETIC IMAGES; RADIOTHERAPY; QUALITY; HEAD; RECONSTRUCTION; IMPLEMENTATION; SYSTEM; IMPACT;
D O I
10.1259/bjr.20180850
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: Determination of the optimal energy level of virtual monochromatic image (VMI) for brain metastases in contrast-enhanced dual-energy CT (DECT) for radiosurgery and assessment of the subjective and objective image quality of VMI at the optimal energy level. Methods: 20 patients (total of 42 metastases) underwent contrast-enhanced DECT. Spectral image analysis of VMIs at energy levels ranging from 40 to 140 keV in 1 keV increments was performed to determine the optimal VMI (VMIopt) as the one corresponding to the highest contrast-to-noise ratio (CNR) between brain parenchyma and the metastases. The objective and subjective values of VMIopt were compared to those of the VMI with 120 kVp equivalent, defined as reference VMI (VMIref, 77 keV). The objective measurement parameters included mean HU value and SD of tumor and brain parenchyma, absolute lesion contrast (LC), and CNR. The subjective measurements included five-point scale assessment of "overall image quality" and "tumor delineation" by three radiation oncologists. Results: The VMI at 63 keV was defined as VMIopt. The LC and CNR of VMI(opt )were significantly (p < 0.01) higher than those of VMIref (LC: 37.4 HU vs 24.7 HU; CNR: 1.1 vs 0.8, respectively). Subjective analysis rated VMl opt significantly (p < 0.01) superior to VMIref with respect to the overall image quality (3.2 vs 2.9, respectively) and tumor delineation (3.5 vs 2.9, respectively). Conclusion: The VMI at 63 keV derived from contrast-enhanced DECT yielded the highest CNR and improved the objective and subjective image quality for radiosurgery, compared to VMIref. Advances in knowledge: This paper investigated for the first time the optimal energy level of VMI in DECT for brain metastases. The findings will lead to improvement in tumor visibility with optimal VMI and consequently supplement accuracy delineation of brain metastases.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Detection of fatty liver using virtual non-contrast dual-energy CT
    Zhang, Pengcheng Peter
    Choi, Hailey H.
    Ohliger, Michael A.
    ABDOMINAL RADIOLOGY, 2022, 47 (06) : 2046 - 2056
  • [32] A novel fast kilovoltage switching dual-energy CT with deep learning: Accuracy of CT number on virtual monochromatic imaging and iodine quantification
    Kojima, Tsukasa
    Shirasaka, Takashi
    Kondo, Masatoshi
    Kato, Toyoyuki
    Nishie, Akihiro
    Ishigami, Kousei
    Yabuuchi, Hidetake
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 81 : 253 - 261
  • [33] Selection of optimal tube potential settings for dual-energy CT virtual mono-energetic imaging of iodine in the abdomen
    Michalak, Gregory
    Grimes, Joshua
    Fletcher, Joel
    Halaweish, Ahmed
    Yu, Lifeng
    Leng, Shuai
    McCollough, Cynthia
    ABDOMINAL RADIOLOGY, 2017, 42 (09) : 2289 - 2296
  • [34] Technical Note: Relation between dual-energy subtraction of CT images for electron density calibration and virtual monochromatic imaging
    Saito, Masatoshi
    MEDICAL PHYSICS, 2015, 42 (07) : 4088 - 4093
  • [35] Virtual monochromatic reconstructions of dual energy CT in abdominal trauma: optimization of energy level improves pancreas laceration conspicuity and diagnostic confidence
    Sugrue, Gavin
    Walsh, John P.
    Zhang, Yilin
    Niu, Bonnie
    Macri, Francesco
    Khasanova, Elina
    Metwally, Omar
    Murray, Nicolas
    Nicolaou, Savvas
    EMERGENCY RADIOLOGY, 2021, 28 (01) : 1 - 7
  • [36] Use of a Noise Optimized Monoenergetic Algorithm for Patient-Size Independent Selection of an Optimal Energy Level During Dual-Energy CT of the Pancreas
    Bellini, Davide
    Gupta, Sonia
    Ramirez-Giraldo, Juan Carlos
    Fu, Wanyi
    Stinnett, Sandra S.
    Patel, Bhavik
    Mileto, Achille
    Marin, Daniele
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2017, 41 (01) : 39 - 47
  • [37] Optimize non -contrast head CT imaging tasks using multiple virtual monochromatic image sets in dual -energy spectral CT />
    Li, Xiaohu
    Li, Zhijie
    Li, Jianying
    Song, Jian
    Yu, Yongqiang
    Liu, Bin
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2020, 28 (02) : 345 - 356
  • [38] Virtual monoenergetic dual-layer dual-energy CT images in colorectal cancer: CT diagnosis could be improved?
    Arico, Francesco Marcello
    Trimarchi, Renato
    Portaluri, Antonio
    Barilla, Claudia
    Migliaccio, Nicola
    Bucolo, Giuseppe Mauro
    Cicero, Giuseppe
    Sofia, Carmelo
    Booz, Christian
    Vogl, Thomas J. J.
    Marino, Maria Adele
    Ascenti, Velio
    D'Angelo, Tommaso
    Mazziotti, Silvio
    Ascenti, Giorgio
    RADIOLOGIA MEDICA, 2023, 128 (08): : 891 - 899
  • [39] Virtual non-calcium dual-energy CT: clinical applications
    D'Angelo, Tommaso
    Albrecht, Moritz H.
    Caudo, Danilo
    Mazziotti, Silvio
    Vogl, Thomas J.
    Wichmann, Julian L.
    Martin, Simon
    Yel, Ibrahim
    Ascenti, Giorgio
    Koch, Vitali
    Cicero, Giuseppe
    Blandino, Alfredo
    Booz, Christian
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2021, 5 (01)
  • [40] Virtual monoenergetic dual-energy CT for evaluation of hepatic and splenic lacerations
    Sun, Ellen X.
    Wortman, Jeremy R.
    Uyeda, Jennifer W.
    Lacson, Roger
    Sodickson, Aaron D.
    EMERGENCY RADIOLOGY, 2019, 26 (04) : 419 - 425