Determination of optimal virtual monochromatic energy level for target delineation of brain metastases in radiosurgery using dual-energy CT

被引:8
|
作者
Karino, Tsukasa [1 ]
Ohira, Shingo [1 ,2 ]
Kanayama, Naoyuki [1 ]
Wada, Kentaro [1 ]
Ikawa, Toshiki [1 ]
Nitta, Yuya [1 ]
Washio, Hayate [1 ]
Miyazaki, Masayoshi [1 ,3 ]
Teshima, Teruki [1 ]
机构
[1] Osaka Int Canc Inst, Dept Radiat Oncol, Osaka, Japan
[2] Osaka Univ, Med, Dept Med Phys & Engn, Osaka, Japan
[3] Hyogo Coll Med, Dept Radiol, Nishinomiya, Hyogo, Japan
关键词
TUMOR VOLUME DELINEATION; COMPUTED-TOMOGRAPHY; MONOENERGETIC IMAGES; RADIOTHERAPY; QUALITY; HEAD; RECONSTRUCTION; IMPLEMENTATION; SYSTEM; IMPACT;
D O I
10.1259/bjr.20180850
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: Determination of the optimal energy level of virtual monochromatic image (VMI) for brain metastases in contrast-enhanced dual-energy CT (DECT) for radiosurgery and assessment of the subjective and objective image quality of VMI at the optimal energy level. Methods: 20 patients (total of 42 metastases) underwent contrast-enhanced DECT. Spectral image analysis of VMIs at energy levels ranging from 40 to 140 keV in 1 keV increments was performed to determine the optimal VMI (VMIopt) as the one corresponding to the highest contrast-to-noise ratio (CNR) between brain parenchyma and the metastases. The objective and subjective values of VMIopt were compared to those of the VMI with 120 kVp equivalent, defined as reference VMI (VMIref, 77 keV). The objective measurement parameters included mean HU value and SD of tumor and brain parenchyma, absolute lesion contrast (LC), and CNR. The subjective measurements included five-point scale assessment of "overall image quality" and "tumor delineation" by three radiation oncologists. Results: The VMI at 63 keV was defined as VMIopt. The LC and CNR of VMI(opt )were significantly (p < 0.01) higher than those of VMIref (LC: 37.4 HU vs 24.7 HU; CNR: 1.1 vs 0.8, respectively). Subjective analysis rated VMl opt significantly (p < 0.01) superior to VMIref with respect to the overall image quality (3.2 vs 2.9, respectively) and tumor delineation (3.5 vs 2.9, respectively). Conclusion: The VMI at 63 keV derived from contrast-enhanced DECT yielded the highest CNR and improved the objective and subjective image quality for radiosurgery, compared to VMIref. Advances in knowledge: This paper investigated for the first time the optimal energy level of VMI in DECT for brain metastases. The findings will lead to improvement in tumor visibility with optimal VMI and consequently supplement accuracy delineation of brain metastases.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Determination of the optimal range for virtual monoenergetic images in dual-energy CT based on physical quality parameters
    Fernandez-Velilla Cepria, Enric
    Angel Gonzalez-Ballester, Miguel
    Quera Jordana, Jaume
    Pera, Oscar
    Sanz Latiesas, Xavier
    Foro Arnalot, Palmira
    Membrive Conejo, Ismael
    Rodriguez de Dios, Nuria
    Reig Castillejo, Anna
    Algara Lopez, Manuel
    MEDICAL PHYSICS, 2021, 48 (09) : 5085 - 5095
  • [2] Dual-Energy CT-Based Monochromatic Imaging
    Yu, Lifeng
    Leng, Shuai
    McCollough, Cynthia H.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (05) : S9 - S15
  • [3] Influence of virtual monochromatic spectral image at different energy levels on motion artifact correction in dual-energy spectral coronary CT angiography
    Jia, Yongjun
    Zhai, Bingying
    He, Taiping
    Yu, Yong
    Yu, Nan
    Duan, Haifeng
    Yang, Chuangbo
    Zhang, Xirong
    JAPANESE JOURNAL OF RADIOLOGY, 2019, 37 (09) : 636 - 641
  • [4] Virtual monochromatic images of dual-energy CT as an alternative to single-energy CT: performance comparison using a detectability index for different acquisition techniques
    Kawashima, Hiroki
    Ichikawa, Katsuhiro
    Ueta, Hiroshi
    Takata, Tadanori
    Mitsui, Wataru
    Nagata, Hiroji
    EUROPEAN RADIOLOGY, 2023, 33 (08) : 5752 - 5760
  • [5] Improving Structure Delineation for Radiation Therapy Planning Using Dual-Energy CT
    Noid, George
    Zhu, Justin
    Tai, An
    Mistry, Nilesh
    Schott, Diane
    Prah, Douglas
    Paulson, Eric
    Schultz, Christopher
    Li, X. Allen
    FRONTIERS IN ONCOLOGY, 2020, 10
  • [6] Implementation of dual-energy technique for virtual monochromatic and linearly mixed CBCTs
    Li, Hao
    Giles, William
    Ren, Lei
    Bowsher, James
    Yin, Fang-Fang
    MEDICAL PHYSICS, 2012, 39 (10) : 6056 - 6064
  • [7] Virtual monochromatic dual-energy CT reconstructions improve detection of cerebral infarct in patients with suspicion of stroke
    van Ommen, Fasco
    Dankbaar, Jan Willem
    Zhu, Guangming
    Wolman, Dylan N.
    Heit, Jeremy J.
    Kauw, Frans
    Bennink, Edwin
    de Jong, Hugo W. A. M.
    Wintermark, Max
    NEURORADIOLOGY, 2021, 63 (01) : 41 - 49
  • [8] Virtual monochromatic image at lower energy level for assessing pancreatic ductal adenocarcinoma in fast kV-switching dual-energy CT
    Noda, Y.
    Goshima, S.
    Kaga, T.
    Ando, T.
    Miyoshi, T.
    Kawai, N.
    Kawada, H.
    Tanahashi, Y.
    Matsuo, M.
    CLINICAL RADIOLOGY, 2020, 75 (04) : 320.e17 - 320.e23
  • [9] Virtual Monochromatic Imaging in Dual-source and Dual-energy CT for Visualization of Acute Ischemic Stroke
    Hara, Hidetake
    Muraishi, Hiroshi
    Matsuzawa, Hiroki
    Inoue, Toshiyuki
    Nakajima, Yasuo
    Satoh, Hitoshi
    Abe, Shinji
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2015, 67 (01) : 103 - 107
  • [10] Virtual monochromatic imaging in dual-source dual-energy CT: Radiation dose and image quality
    Yu, Lifeng
    Christner, Jodie A.
    Leng, Shuai
    Wang, Jia
    Fletcher, Joel G.
    McCollough, Cynthia H.
    MEDICAL PHYSICS, 2011, 38 (12) : 6371 - 6379