Clinical Performance of Samfilcon A Contact Lenses in Intensive Digital Device Users: A Multicenter, Prospective Clinical Study

被引:2
作者
Ucakhan, Omur O. [1 ]
Tasindi, Emrullah [2 ]
Toker, Ebru [3 ]
Ciftci, Ferda [4 ]
Kurna, Sevda Aydin [5 ]
Acar, Mutlu [6 ]
Ozcelik, Ferah [7 ]
Celebi, Ali Riza Cenk [8 ]
Yildiz, Hatice Elvin [9 ]
Akova, Yonca Aydin [10 ]
Oncu, Emine Sibel [11 ]
Ozbek, Zeynep [12 ]
Tuncer, Zerrin [13 ]
Kocabeyoglu, Sibel
Seker, Burak [14 ]
Kaya, Deniz [14 ]
Barakat, Maxime [15 ]
机构
[1] Ankara Univ, Dept Ophthalmol, Sch Med, Ankara, Turkey
[2] Istanbul Okan Univ, Dept Ophthalmol, Fac Med, Istanbul, Turkey
[3] Marmara Univ Pendik Training & Res Hosp, Dept Ophthalmol, Istanbul, Turkey
[4] Batigoz Altunizade Hosp, Dept Ophthalmol, Istanbul, Turkey
[5] Fatih Sultan Mehmet Training & Res Hosp, Dept Ophthalmol, Istanbul, Turkey
[6] Diskapi Yildinm Beyazit Training & Res Hosp, Dept Ophthalmol, Ankara, Turkey
[7] Prof Dr Resat Belger Beyoglu Training & Res Hosp, Dept Ophthalmol, Istanbul, Turkey
[8] Acibadem Atakent Hosp, Dept Ophthalmol, Istanbul, Turkey
[9] Haydarpasa Numune Training & Res Hosp, Dept Ophthalmol, Istanbul, Turkey
[10] Bayindir Kavakhdere Hosp, Dept Ophthalmol, Ankara, Turkey
[11] Birinci Eye Hosp, Dept Ophthalmol, Istanbul, Turkey
[12] 9 Eyliil Univ Hosp, Dept Ophthalmol, Izmir, Turkey
[13] Getz Vakfi Bayrampasa Eye Hosp, Dept Ophthalmol, Istanbul, Turkey
[14] Bausch Lomb, Istanbul, Turkey
[15] Bausch Hlth, Laval, PQ, Canada
关键词
Computer vision syndrome; Contact lens; Contact lens discomfort; Digital eye strain; Dry eye; Myopia; Patient preference; satisfaction; Samfilcon A; Soft contact lens; Visual acuity; TFOS INTERNATIONAL WORKSHOP; VISUAL-DISPLAY TERMINALS; BLINK RATE; SYMPTOMS; PATTERNS; COMFORT; SURFACE; WEAR;
D O I
10.1007/s40123-021-00389-4
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Introduction To evaluate patient satisfaction with samfilcon A contact lenses (CLs) in intensive digital device users with myopia and to compare patient satisfaction with samfilcon A lenses to prior experience with senofilcon A or lotrafilcon B CLs. Methods This was a comparative, prospective, national study conducted at 14 centers in Turkey. Subjects were adults aged 18 and 45 years with myopia (range -0.25 D to -6.00 D) who spend a minimum of 3 hours viewing digital devices (e.g., computer, smartphone). A subgroup of patients were habitual lens wearers (senofilcon A or lotrafilcon B lens wear for at least 6 months prior to enrollment). The primary assessment was patient satisfaction with samfilcon A lenses (0-100 Likert scale). Secondary assessments included patient satisfaction with samfilcon A lenses compared to patients' habitual lenses, investigator satisfaction with samfilcon A lenses and investigator-evaluated slit lamp examination findings. Results Samfilcon A lenses were given high overall ratings from both patients and investigators, with a low incidence of ocular symptoms. Overall, patients were highly satisfied with samfilcon A lenses for comfort, vision and overall performance, and stated that they would consider wearing these lenses in the future. Among habitual senofilcon A or lotrafilcon B lens wearers, samfilcon A lenses were rated significantly better than the habitual lenses in regard to comfort, vision and overall performance. Investigator assessments were also highly favorable, both at initial fit and after 4 weeks of follow-up, with no significant findings noted on slit lamp examination. Conclusion Samfilcon A lenses were rated highly by investigators in regard to fit, handling and slit lamp findings, and by novice and habitual lens wearers in regard to comfort, vision and overall performance. These results support the use of samfilcon A lenses among digital device users who seek day-long comfort and good visual acuity.
引用
收藏
页码:957 / 972
页数:16
相关论文
共 50 条
  • [41] Clinical Performance & Patient Satisfaction of Monolithic Zirconia (5Y), Lithium Disilicate and Modified PEEK CAD-CAM Endocrown Materials: 3-Year Clinical Prospective Study
    Tammam, Raafat
    Abuzinadah, D. Samar Hatem
    Alhaddad, D. Abdulrahman Jafar
    [J]. JOURNAL OF RESEARCH IN MEDICAL AND DENTAL SCIENCE, 2021, 9 (10): : 209 - 220
  • [42] Performance of high-translucent zirconia CAD/CAM fixed dental prostheses using a digital workflow: A clinical study up to 6 years
    Guncu, Mustafa Baris
    Aktas, Guliz
    Turkyilmaz, Ilser
    Gavras, Nicolette
    [J]. JOURNAL OF DENTAL SCIENCES, 2023, 18 (01) : 44 - 49
  • [43] Reduction of Leg Pain by Oxiplex Gel After Lumbar Discectomy in Patients With Predominant Leg Pain and Elevated Levels of Lower Back Pain A Prospective, Randomized, Blinded, Multicenter Clinical Study
    Lei, Wei
    Ehmsen, Ronald J.
    Chiacchierini, Richard P.
    Krelle, John L.
    diZerega, Gere S.
    [J]. JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2015, 28 (08): : 301 - 307
  • [44] Evaluation of clinical performance and safety for the rechargeable InterStim Micro device in overactive bladder subjects: 6-month results from the global postmarket ELITE study
    Goudelocke, Colin
    Xavier, Keith
    Pecha, Barry
    Burgess, Kimberly
    Perrouin-Verbe, Marie-A.
    Krlin, Ryan
    Michaels, Jodi
    Shah, Sagar
    Peyronnet, Benoit
    Zaslau, Stanley
    Champs, Mylene
    Papi, Bianca
    Bittner, Katie
    Elterman, Dean
    Nitti, Victor
    [J]. NEUROUROLOGY AND URODYNAMICS, 2023, 42 (04) : 761 - 769
  • [45] A prospective clinical study to evaluate the performance of zirconium dioxide dental implants in single-tooth edentulous area: 3-year follow-up
    Bormann, Kai-Hendrik
    Gellrich, Nils-Claudius
    Kniha, Heinz
    Schild, Sabine
    Weingart, Dieter
    Gahlert, Michael
    [J]. BMC ORAL HEALTH, 2018, 18
  • [46] Risk factors, clinical correlates, and social functions of Chinese schizophrenia patients with drug-induced parkinsonism: A cross-sectional analysis of a multicenter, observational, real-world, prospective cohort study
    Weng, Jiajun
    Zhang, Lei
    Yu, Wenjuan
    Zhao, Nan
    Zhu, Binggen
    Ye, Chengyu
    Zhang, Zhanxing
    Ma, Changlin
    Li, Yan
    Yu, Yiming
    Li, Huafang
    [J]. FRONTIERS IN PHARMACOLOGY, 2023, 14
  • [47] Real- world outcomes on myopia management efficacy of diverse segmented defocus optics (DSDO) and defocus incorporated multiple segments (DIMS) spectacle lenses in Chinese children: An initial 12- month prospective clinical study
    Fan, Yuzhuo
    Chu, Huihui
    Peng, Zisu
    Zhou, Jingwei
    Ma, Jiahui
    Lu, Yuchang
    Zhao, Chenxu
    Wang, Yanyan
    Deng, Qiulin
    Yu, Jifeng
    Li, Yan
    Wang, Kai
    Zhao, Mingwei
    [J]. JOURNAL OF OPTOMETRY, 2025, 18 (01)
  • [48] Radiographic evaluation of immediately loaded implants supporting 2-3 units fixed bridges in the posterior maxilla: a 3-year follow-up prospective randomized controlled multicenter clinical study
    Cesaretti, Gianfranco
    Botticelli, Daniele
    Renzi, Antonio
    Rossi, Marcello
    Rossi, Riccardo
    Lang, Niklaus P.
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (04) : 399 - 405
  • [49] Safety, effectiveness, and economic evaluation of an herbal medicine, Ukgansangajinpibanha granule, in children with autism spectrum disorder: a study protocol for a prospective, multicenter, randomized, double-blinded, placebo-controlled, parallel-group clinical trial
    Lee, Sun Haeng
    Shin, Seungwon
    Kim, Tae-hun
    Kim, Sang Min
    Do, Tae Yoon
    Park, Sulgi
    Lee, Boram
    Shin, Hye Jin
    Lee, Jihong
    Lee, Jin Yong
    Chang, Gyu Tae
    [J]. TRIALS, 2019, 20 (1)
  • [50] Nonsurgical treatment of peri-implantitis using an air-abrasive device or mechanical debridement and local application of chlorhexidine. Twelve-month follow-up of a prospective, randomized, controlled clinical study
    John, Gordon
    Sahm, Narja
    Becker, Juergen
    Schwarz, Frank
    [J]. CLINICAL ORAL INVESTIGATIONS, 2015, 19 (08) : 1807 - 1814