Clinical Performance of Samfilcon A Contact Lenses in Intensive Digital Device Users: A Multicenter, Prospective Clinical Study

被引:2
|
作者
Ucakhan, Omur O. [1 ]
Tasindi, Emrullah [2 ]
Toker, Ebru [3 ]
Ciftci, Ferda [4 ]
Kurna, Sevda Aydin [5 ]
Acar, Mutlu [6 ]
Ozcelik, Ferah [7 ]
Celebi, Ali Riza Cenk [8 ]
Yildiz, Hatice Elvin [9 ]
Akova, Yonca Aydin [10 ]
Oncu, Emine Sibel [11 ]
Ozbek, Zeynep [12 ]
Tuncer, Zerrin [13 ]
Kocabeyoglu, Sibel
Seker, Burak [14 ]
Kaya, Deniz [14 ]
Barakat, Maxime [15 ]
机构
[1] Ankara Univ, Dept Ophthalmol, Sch Med, Ankara, Turkey
[2] Istanbul Okan Univ, Dept Ophthalmol, Fac Med, Istanbul, Turkey
[3] Marmara Univ Pendik Training & Res Hosp, Dept Ophthalmol, Istanbul, Turkey
[4] Batigoz Altunizade Hosp, Dept Ophthalmol, Istanbul, Turkey
[5] Fatih Sultan Mehmet Training & Res Hosp, Dept Ophthalmol, Istanbul, Turkey
[6] Diskapi Yildinm Beyazit Training & Res Hosp, Dept Ophthalmol, Ankara, Turkey
[7] Prof Dr Resat Belger Beyoglu Training & Res Hosp, Dept Ophthalmol, Istanbul, Turkey
[8] Acibadem Atakent Hosp, Dept Ophthalmol, Istanbul, Turkey
[9] Haydarpasa Numune Training & Res Hosp, Dept Ophthalmol, Istanbul, Turkey
[10] Bayindir Kavakhdere Hosp, Dept Ophthalmol, Ankara, Turkey
[11] Birinci Eye Hosp, Dept Ophthalmol, Istanbul, Turkey
[12] 9 Eyliil Univ Hosp, Dept Ophthalmol, Izmir, Turkey
[13] Getz Vakfi Bayrampasa Eye Hosp, Dept Ophthalmol, Istanbul, Turkey
[14] Bausch Lomb, Istanbul, Turkey
[15] Bausch Hlth, Laval, PQ, Canada
关键词
Computer vision syndrome; Contact lens; Contact lens discomfort; Digital eye strain; Dry eye; Myopia; Patient preference; satisfaction; Samfilcon A; Soft contact lens; Visual acuity; TFOS INTERNATIONAL WORKSHOP; VISUAL-DISPLAY TERMINALS; BLINK RATE; SYMPTOMS; PATTERNS; COMFORT; SURFACE; WEAR;
D O I
10.1007/s40123-021-00389-4
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Introduction To evaluate patient satisfaction with samfilcon A contact lenses (CLs) in intensive digital device users with myopia and to compare patient satisfaction with samfilcon A lenses to prior experience with senofilcon A or lotrafilcon B CLs. Methods This was a comparative, prospective, national study conducted at 14 centers in Turkey. Subjects were adults aged 18 and 45 years with myopia (range -0.25 D to -6.00 D) who spend a minimum of 3 hours viewing digital devices (e.g., computer, smartphone). A subgroup of patients were habitual lens wearers (senofilcon A or lotrafilcon B lens wear for at least 6 months prior to enrollment). The primary assessment was patient satisfaction with samfilcon A lenses (0-100 Likert scale). Secondary assessments included patient satisfaction with samfilcon A lenses compared to patients' habitual lenses, investigator satisfaction with samfilcon A lenses and investigator-evaluated slit lamp examination findings. Results Samfilcon A lenses were given high overall ratings from both patients and investigators, with a low incidence of ocular symptoms. Overall, patients were highly satisfied with samfilcon A lenses for comfort, vision and overall performance, and stated that they would consider wearing these lenses in the future. Among habitual senofilcon A or lotrafilcon B lens wearers, samfilcon A lenses were rated significantly better than the habitual lenses in regard to comfort, vision and overall performance. Investigator assessments were also highly favorable, both at initial fit and after 4 weeks of follow-up, with no significant findings noted on slit lamp examination. Conclusion Samfilcon A lenses were rated highly by investigators in regard to fit, handling and slit lamp findings, and by novice and habitual lens wearers in regard to comfort, vision and overall performance. These results support the use of samfilcon A lenses among digital device users who seek day-long comfort and good visual acuity.
引用
收藏
页码:957 / 972
页数:16
相关论文
共 50 条
  • [1] Clinical Performance of Samfilcon A Contact Lenses in Intensive Digital Device Users: A Multicenter, Prospective Clinical Study
    Ömür Ö. Uçakhan
    Emrullah Taşındı
    Ebru Toker
    Ferda Çiftçi
    Sevda Aydın Kurna
    Mutlu Acar
    Ferah Özçelik
    Ali Rıza Cenk Çelebi
    Hatice Elvin Yıldız
    Yonca Aydın Akova
    Emine Sibel Öncü
    Zeynep Özbek
    Zerrin Tuncer
    Sibel Kocabeyoğlu
    Burak Şeker
    Deniz Kaya
    Maxime Barakat
    Ophthalmology and Therapy, 2021, 10 : 957 - 972
  • [2] Evaluating the Performance of Verofilcon A Daily Disposable Contact Lenses in a Group of Heavy Digital Device Users
    Schulze, Marc-Matthias
    Fadel, Daddi
    Luensmann, Doerte
    Ng, Alison
    Guthrie, Sarah
    Woods, Jill
    Jones, Lyndon
    CLINICAL OPHTHALMOLOGY, 2023, 17 : 3165 - 3176
  • [3] Performance of a Toric, Monthly, Soft Contact Lens in Digital Device Users
    Pucker, Andrew D.
    Franklin, Quentin X.
    Perkins, Amy F.
    May, Kristopher
    Kannarr, Shane R.
    Bromley, Morgan
    Lievens, Chris
    CLINICAL OPTOMETRY, 2025, 17 : 11 - 20
  • [4] Clinical performance of different care systems with silicone hydrogel contact lenses
    Keir, Nancy
    Woods, Craig A.
    Dumbleton, Kathryn
    Jones, Lyndon
    CONTACT LENS & ANTERIOR EYE, 2010, 33 (04): : 189 - 195
  • [5] Clinical performance and Willingness To Pay for soft toric contact lenses in low and moderate astigmats
    Morgan, O. Ashton
    Mirza, Aftab A.
    Parmar, Ketan R.
    Plowright, Andrew J.
    Vega, Jose A.
    Orsborn, Gary N.
    Maldonado-Codina, Carole
    Whitehead, John C.
    Morgan, Philip B.
    CONTACT LENS & ANTERIOR EYE, 2023, 46 (05):
  • [6] Clinical performance of a custom-designed soft contact lens in patients with keratoconus and intolerance to rigid contact lenses
    Hiraoka, Takahiro
    Kiuchi, Gaku
    Hiraoka, Reia
    Oshika, Tetsuro
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2022, 66 (04) : 350 - 357
  • [7] Clinical performance of a custom-designed soft contact lens in patients with keratoconus and intolerance to rigid contact lenses
    Hiraoka, Takahiro
    Kiuchi, Gaku
    Hiraoka, Reia
    Oshika, Tetsuro
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2022,
  • [8] Clinical performance of a custom-designed soft contact lens in patients with keratoconus and intolerance to rigid contact lenses
    Takahiro Hiraoka
    Gaku Kiuchi
    Reia Hiraoka
    Tetsuro Oshika
    Japanese Journal of Ophthalmology, 2022, 66 : 350 - 357
  • [9] Objective clinical performance of 'comfort-enhanced' daily disposable soft contact lenses
    Wolffsohn, James S.
    Hunt, Olivia A.
    Chowdhury, Ashock
    CONTACT LENS & ANTERIOR EYE, 2010, 33 (02): : 88 - 92
  • [10] Clinical findings in Bordetella pertussis infections: Results of a prospective multicenter surveillance study
    Heininger, U
    Klich, K
    Stehr, K
    Cherry, JD
    PEDIATRICS, 1997, 100 (06) : E10