Sodium hypochlorite dosage for household and emergency water treatment - Response

被引:72
作者
不详
机构
[1] Enteric Diseases Epidemiology Branch, M/S A-38, Centers for Disease Control and Prevention, Atlanta, GA 30333
来源
JOURNAL AMERICAN WATER WORKS ASSOCIATION | 2008年 / 100卷 / 08期
关键词
D O I
10.1002/j.1551-8833.2008.tb09704.x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
For the 1.1 billion people worldwide who do not have access to improved drinking water supply, point-of-use (POU) water treatment with sodium hypochlorite (NaOCl) is proven to reduce the incidence of diarrheal disease. However, NaOQ dosage recommendations for both household water treatment and disaster response water treatment vary significantly. In this study, 106 water samples front a variety of unproved and unimproved sources in 16 countries were tested ep ascertain whether a standardized NaOCl dosage regime could be developed. Results indicated that for household water treatment with NaOCl alone, a dose of 1.875 mg/L NaOCl proved effective in 86.6% of samples with turbidity < 10 ntu and a dose of 3.75 mg/L NaOCl was effective in 91.7% of unimproved sources with turbidity of 10-100 ntu. On the basis of test results, it is also recommended that POU chlorination programs adopt a proposed criteria for a free chlorine residual of < 2.0 mg/L 1 hour after NaOCl addition and > 0.2 mg/L after 24 hours of storage.
引用
收藏
页码:131 / 131
页数:1
相关论文
共 29 条
[1]   MALNUTRITION, CELL-MEDIATED IMMUNE-DEFICIENCY, AND DIARRHEA - A COMMUNITY-BASED LONGITUDINAL-STUDY IN RURAL BANGLADESHI CHILDREN [J].
BAQUI, AH ;
BLACK, RE ;
SACK, RB ;
CHOWDHURY, HR ;
YUNUS, M ;
SIDDIQUE, AK .
AMERICAN JOURNAL OF EPIDEMIOLOGY, 1993, 137 (03) :355-365
[2]  
BARTRAM J, 2005, COMMUNICATION
[3]  
*CDC, 2006, EFF CHLOR IN SEL MIC
[4]  
Chiller TM, 2006, B WORLD HEALTH ORGAN, V84, P28, DOI 10.2471/BLT.04.016980
[5]   Household based treatment of drinking water with flocculant-disinfectant for preventing diarrhoea in areas with turbid source water in rural western Kenya: cluster randomised controlled trial [J].
Crump, JA ;
Otieno, PO ;
Slutsker, L ;
Keswick, BH ;
Rosen, DH ;
Hoekstra, RM ;
Vulule, JM ;
Luby, SP .
BMJ-BRITISH MEDICAL JOURNAL, 2005, 331 (7515) :478-481
[6]   Effect of point-of-use disinfection, flocculation and combined flocculation-disinfection on drinking water quality in western Kenya [J].
Crump, JA ;
Okoth, GO ;
Slutsker, L ;
Ogaja, DO ;
Keswick, BH ;
Luby, SP .
JOURNAL OF APPLIED MICROBIOLOGY, 2004, 97 (01) :225-231
[7]   The role of public health improvements in health advances: The twentieth-century United States [J].
Cutler, D ;
Miller, G .
DEMOGRAPHY, 2005, 42 (01) :1-22
[8]   Water, sanitation and hygiene in developing countries: interventions and diarrhoea - a review [J].
Fewtrell, L ;
Colford, JM .
WATER SCIENCE AND TECHNOLOGY, 2005, 52 (08) :133-142
[9]   Association of early childhood diarrhea and cryptosporidiosis with impaired physical fitness and cognitive function four-seven years later in a poor urban community in northeast brazil [J].
Guerrant, DI ;
Moore, SR ;
Lima, AAM ;
Patrick, PD ;
Schorling, JB ;
Guerrant, RL .
AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 1999, 61 (05) :707-713
[10]   Disinfection by-product formation and mitigation strategies in point-of-use chlorination of turbid and non-turbid waters in western Kenya [J].
Lantagne, D. S. ;
Blount, B. C. ;
Cardinali, F. ;
Quick, R. .
JOURNAL OF WATER AND HEALTH, 2008, 6 (01) :67-82