Body MR Imaging: Artifacts, k-Space, and Solutions

被引:89
作者
Huang, Susie Y. [1 ,2 ]
Seethamraju, Ravi T. [4 ]
Patel, Pritesh [3 ]
Hahn, Peter F. [1 ]
Kirsch, John E. [4 ]
Guimaraes, Alexander R. [1 ,2 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
[2] Massachusetts Gen Hosp, Athinoula A Martinos Ctr Biomed Imaging, Dept Radiol, Boston, MA 02114 USA
[3] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
[4] Siemens Healthcare USA, Malvern, PA USA
基金
美国国家卫生研究院;
关键词
SPIN-ECHO; PRINCIPLES; REDUCTION; SENSE; COILS;
D O I
10.1148/rg.2015140289
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Body magnetic resonance (MR) imaging is challenging because of the complex interaction of multiple factors, including motion arising from respiration and bowel peristalsis, susceptibility effects secondary to bowel gas, and the need to cover a large field of view. The combination of these factors makes body MR imaging more prone to artifacts, compared with imaging of other anatomic regions. Understanding the basic MR physics underlying artifacts is crucial to recognizing the trade-offs involved in mitigating artifacts and improving image quality. Artifacts can be classified into three main groups: (a) artifacts related to magnetic field imperfections, including the static magnetic field, the radiofrequency (RF) field, and gradient fields; (b) artifacts related to motion; and (c) artifacts arising from methods used to sample the MR signal. Static magnetic field homogeneity is essential for many MR techniques, such as fat saturation and balanced steady-state free precession. Susceptibility effects become more pronounced at higher field strengths and can be ameliorated by using spin-echo sequences when possible, increasing the receiver bandwidth, and aligning the phase-encoding gradient with the strongest susceptibility gradients, among other strategies. Nonuniformities in the RF transmit field, including dielectric effects, can be minimized by applying dielectric pads or imaging at lower field strength. Motion artifacts can be overcome through respiratory synchronization, alternative k-space sampling schemes, and parallel imaging. Aliasing and truncation artifacts derive from limitations in digital sampling of the MR signal and can be rectified by adjusting the sampling parameters. Understanding the causes of artifacts and their possible solutions will enable practitioners of body MR imaging to meet the challenges of novel pulse sequence design, parallel imaging, and increasing field strength. (C) RSNA, 2015
引用
收藏
页码:1439 / 1460
页数:22
相关论文
共 29 条
[1]   RESPIRATORY ORDERED PHASE ENCODING (ROPE) - A METHOD FOR REDUCING RESPIRATORY MOTION ARTIFACTS IN MR IMAGING [J].
BAILES, DR ;
GILDERDALE, DJ ;
BYDDER, GM ;
COLLINS, AG ;
FIRMIN, DN .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1985, 9 (04) :835-838
[2]   Imaging artifacts at 3.OT [J].
Bernstein, Matt A. ;
Huston, John, III ;
Ward, Heidi A. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (04) :735-746
[3]   Fat and Water Magnetic Resonance Imaging [J].
Bley, Thorsten A. ;
Wieben, Oliver ;
Francois, Christopher J. ;
Brittain, Jean H. ;
Reeder, Scott B. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (01) :4-18
[4]   Principles, Techniques, and Applications of T2*-based MR Imaging and Its Special Applications [J].
Chavhan, Govind B. ;
Babyn, Paul S. ;
Thomas, Bejoy ;
Shroff, Manohar M. ;
Haacke, E. Mark .
RADIOGRAPHICS, 2009, 29 (05) :1433-U272
[5]   Artifacts in 3-T MRI: Physical background and reduction strategies [J].
Dietrich, Olaf ;
Reiser, Maximilian F. ;
Schoenberg, Stefan O. .
EUROPEAN JOURNAL OF RADIOLOGY, 2008, 65 (01) :29-35
[6]   Technical aspects of MR diffusion imaging of the body [J].
Dietrich, Olaf ;
Biffar, Andreas ;
Baur-Melnyk, Andrea ;
Reiser, Maximilian F. .
EUROPEAN JOURNAL OF RADIOLOGY, 2010, 76 (03) :314-322
[7]   Parallel MR imaging: A user's guide [J].
Glockner, JF ;
Hu, HH ;
Stanley, DW ;
Angelos, L ;
King, K .
RADIOGRAPHICS, 2005, 25 (05) :1279-1297
[8]   Body MRI artifacts in clinical practice: A physicist's and radiologist's perspective [J].
Graves, Martin J. ;
Mitchell, Donald G. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 38 (02) :269-287
[9]   Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) [J].
Griswold, MA ;
Jakob, PM ;
Heidemann, RM ;
Nittka, M ;
Jellus, V ;
Wang, JM ;
Kiefer, B ;
Haase, A .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1202-1210
[10]  
HAACKE E M, 1986, Magnetic Resonance Imaging, V4, P359, DOI 10.1016/0730-725X(86)91046-5