External beam radiotherapy cone beam computed tomography-based dose calculation

被引:0
作者
Barateau, Anais [1 ,2 ]
Celeste, Marc [3 ]
Lafond, Caroline [1 ,2 ,3 ]
Henry, Olivier [3 ]
Couespel, Solene [3 ]
Simon, Antoine [1 ,2 ]
Acosta, Oscar [1 ,2 ]
de Crevoisier, Renaud [1 ,2 ,3 ]
Perichon, Nicolas [3 ]
机构
[1] INSERM, U1099, Campus Beaulieu,263 Ave Gen Leclerc, F-35000 Rennes, France
[2] Univ Rennes 1, LTSI, Campus Beaulieu,263 Ave Gen Leclerc,CS 74205, F-35042 Rennes, France
[3] Ctr Eugene Marquis, Dept Radiotherapie, Rue Bataille Flandres Dunkerque,CS 44229, F-35042 Rennes, France
来源
CANCER RADIOTHERAPIE | 2018年 / 22卷 / 01期
关键词
D O I
10.1016/j.canrad.2017.12.001
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
In external beam radiotherapy, the dose planning is currently based on computed tomography (CT) images. A relation between Hounsfield numbers and electron densities (or mass densities) is necessary for dose calculation taking heterogeneities into account. In image-guided radiotherapy process, the cone beam CT is classically used for tissue visualization and registration. Cone beam CT for dose calculation is also attractive in dose reporting/monitoring perspectives and particularly in a context of dose-guided adaptive radiotherapy. The accuracy of cone beam CT-based dose calculation is limited by image characteristics such as quality, Hounsfield numbers consistency and restrictive sizes of volume acquisition. The analysis of the literature identifies three kinds of strategies for cone beam CT-based dose calculation: establishment of Hounsfield numbers versus densities curves, density override to regions of interest, and deformable registration between CT and cone beam CT images. Literature results show that discrepancies between the reference CT-based dose calculation and the cone beam CT-based dose calculation are often lower than 3%, regardless of the method. However, they can also reach 10% with unsuitable method. Even if the accuracy of the cone beam CT-based dose calculation is independent of the method, some strategies are promising but need improvements in the automating process for a routine implementation. (C) 2017 Societe francaise de radiotherapie oncologique (SFRO). Published by Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:105 / 105
页数:1
相关论文
共 83 条
[21]   Accuracy of dose calculations on kV cone beam CT images of lung cancer patients [J].
de Smet, Mariska ;
Schuring, Danny ;
Nijsten, Sebastiaan ;
Verhaegen, Frank .
MEDICAL PHYSICS, 2016, 43 (11) :5934-5941
[22]   Image-guided radiotherapy: Overview of devices and practice in France in 2015 [J].
Delpon, G. ;
Chiavassa, S. ;
Supiot, S. ;
Boutry, C. ;
Darreon, J. ;
Desrousseaux, J. ;
Lafay, F. ;
Leysalle, A. ;
de Crevoisier, R. .
CANCER RADIOTHERAPIE, 2015, 19 (6-7) :501-507
[23]  
Delpon G, 29 SFPM
[24]   A study on adaptive IMRT treatment planning using kV cone-beam CT [J].
Ding, George X. ;
Duggan, Dennis M. ;
Coffey, Charles W. ;
Deeley, Matthew ;
Hallahan, Dennis E. ;
Cmelak, Anthony ;
Malcolm, Arnold .
RADIOTHERAPY AND ONCOLOGY, 2007, 85 (01) :116-125
[25]   'artificial' electron disequilibrium due to cone-beam CT density errors: implications for on-line adaptive stereotactic body radiation therapy of lung (vol 58, pg 4157, 2013) [J].
Disher, Brandon ;
Hajdok, George ;
Wang, An ;
Craig, Jeff ;
Gaede, Stewart ;
Battista, Jerry J. .
PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (12) :4157-4174
[26]   Comparison of CT number calibration techniques for CBCT-based dose calculation [J].
Dunlop, Alex ;
McQuaid, Dualta ;
Nill, Simeon ;
Murray, Julia ;
Poludniowski, Gavin ;
Hansen, Vibeke N. ;
Bhide, Shreerang ;
Nutting, Christopher ;
Harrington, Kevin ;
Newbold, Kate ;
Oelfke, Uwe .
STRAHLENTHERAPIE UND ONKOLOGIE, 2015, 191 (12) :970-978
[27]   The impact of CBCT reconstruction and calibration for radiotherapy planning in the head and neck region - a phantom study [J].
Elstrom, Ulrik V. ;
Olsen, Sune R. K. ;
Muren, Ludvig P. ;
Petersen, Jorgen B. B. ;
Grau, Cai .
ACTA ONCOLOGICA, 2014, 53 (08) :1114-1124
[28]   Evaluation of image quality for different kV cone-beam CT acquisition and reconstruction methods in the head and neck region [J].
Elstrom, Ulrik V. ;
Muren, Ludvig P. ;
Petersen, Jorgen B. B. ;
Grau, Cai .
ACTA ONCOLOGICA, 2011, 50 (06) :908-917
[29]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619
[30]   Feasibility of CBCT-based dose calculation: Comparative analysis of HU adjustment techniques [J].
Fotina, Irina ;
Hopfgartner, Johannes ;
Stock, Markus ;
Steininger, Thomas ;
Luetgendorf-Caucig, Carola ;
Georg, Dietmar .