da Vinci Skills Simulator Construct Validation Study: Correlation of Prior Robotic Experience With Overall Score and Time Score Simulator Performance EDITORIAL COMMENT

被引:0
作者
Sundaram, Chandru P. [1 ]
机构
[1] Indiana Univ Sch Med, Indianapolis, IN USA
关键词
D O I
10.1016/j.urology.2012.02.062
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE To assess the construct validity of the da Vinci Skills Simulator (Intuitive Surgical, Sunnyvale, CA). Ideally, a well-designed simulator should demonstrate construct validity, which is defined in this study as the correlation between robotic surgical experience and performance on the simulator. PATIENTS AND METHODS Thirty-nine surgeons (18 [46%] group I [0-20 robotic cases]; 8 [21%] group II [21-150 robotic cases]; and 13 [33%] group III [> 150 robotic cases]) were enrolled from September 2010 to December 2010. Participants completed 24 virtual-reality exercises on the da Vinci Skills Simulator. Data on 12 performance metrics were collected by the software. Overall means for score and time across exercises were analyzed. RESULTS Overall scores (64.7%/79.1%/87.4%) and time scores (39.1%/ 58.6%/87.3%) were significantly different among surgeons in groups I-III (P <.001) and demonstrated significant linear relationships (P <.001) for all 24 exercises. Comparisons between the 3 groups using a univariate general linear model (GLM) was used to compare groups I and II and II and III. Groups I and II differed using overall score for 15 exercises and time score for 11 exercises. Groups II and III differed using overall score for 6 exercises and time score for 15 exercises. Mean overall score for 1 exercise displayed significance between both groups I and II and II and III; while using time score, 5 exercises displayed significance between surgeons in groups I and II and II and III. CONCLUSION Initial construct validity analysis revealed that both overall scores and time scores showed a significant linear relationship when comparing the surgeons in groups I, II, and III. Overall score seems to be a stronger indicator for differences between surgeons in groups I and II. Time score seems to be a stronger indicator for differences between surgeons in groups II and III. UROLOGY 80: 330-336, 2012. (c) 2012 Elsevier Inc.
引用
收藏
页码:335 / 335
页数:1
相关论文
共 11 条
[1]   Virtual reality-assisted robotic surgery simulation [J].
Albani, Justin M. ;
Lee, David I. .
JOURNAL OF ENDOUROLOGY, 2007, 21 (03) :285-287
[2]   Warm-up in a Virtual Reality Environment Improves Performance in the Operating Room [J].
Calatayud, Dan ;
Arora, Sonal ;
Aggarwal, Rajesh ;
Kruglikova, Irina ;
Schulze, Svend ;
Funch-Jensen, Peter ;
Grantcharov, Teodor .
ANNALS OF SURGERY, 2010, 251 (06) :1181-1185
[3]  
Do Ann T, 2006, JSLS, V10, P297
[4]   Face, Content and Construct Validity of a Novel Robotic Surgery Simulator [J].
Hung, Andrew J. ;
Zehnder, Pascal ;
Patil, Mukul B. ;
Cai, Jie ;
Ng, Casey K. ;
Aron, Monish ;
Gill, Inderbir S. ;
Desai, Mihir M. .
JOURNAL OF UROLOGY, 2011, 186 (03) :1019-1024
[5]  
Jin Linda X, 2011, J Healthc Qual, V33, P48, DOI 10.1111/j.1945-1474.2011.00148.x
[6]   Effect of Short-Term Pretrial Practice on Surgical Proficiency in Simulated Environments: A Randomized Trial of the "Preoperative Warm-Up" Effect [J].
Kahol, Kanav ;
Satava, Richard M. ;
Ferrara, John ;
Smith, Marshall L. .
JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2009, 208 (02) :255-268
[7]   Face, Content, and Construct Validity of dV-Trainer, a Novel Virtual Reality Simulator for Robotic Surgery [J].
Kenney, Patrick A. ;
Wszolek, Matthew F. ;
Gould, Justin J. ;
Libertino, John A. ;
Moinzadeh, Alireza .
UROLOGY, 2009, 73 (06) :1288-1292
[8]  
Kolata G., 2010, NY TIMES, pA1
[9]  
Lendvay TS, 2008, ST HEAL T, V132, P242
[10]   Does Training on a Virtual Reality Robotic Simulator Improve Performance on the da Vinci® Surgical System? [J].
Lerner, Michelle A. ;
Ayalew, Mikias ;
Peine, William J. ;
Sundaram, Chandru P. .
JOURNAL OF ENDOUROLOGY, 2010, 24 (03) :467-472