Multiwalled Carbon Nanotubes Modified by NTA-Copper Complex for Label-Free Electrochemical Immunosensor Detection

被引:17
作者
Chebil, S. [1 ,2 ]
Macauley, N. [1 ,2 ,3 ]
Hianik, T. [3 ]
Korri-Youssoufi, H. [1 ,2 ]
机构
[1] Univ Paris 11, CNRS UMR 8182, ICMMO, ECBB, F-91405 Orsay, France
[2] Univ Paris 11, F-91405 Orsay, France
[3] Comenius Univ, Fac Math Phys & Informat, Dept Nucl Phys & Biophys, Bratislava 84248, Slovakia
关键词
Biosensors; Deep vein thrombosis; Label-free detection; MWCNT; NTA; copper; DIRECT ELECTRON-TRANSFER; D-DIMER; BINDING; BIOSENSORS; PROTEINS; AFFINITY;
D O I
10.1002/elan.201200298
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A biomaterial based on multiwalled carbon nanotubes (MWCNTs) modified with His-tagged single chain D-dimer antibody trough nitrilo-triacetic-acid (NTA)/copper complex was designed for monitoring D-dimers, which were used as biomarkers of Deep Vein Thrombosis (DVT). The immunosensing evaluation of D-Dimer was followed by measuring the redox process of such complex. We demonstrate that using simple chemistry and exploiting the high surface area, electronic properties of MWCNTs and redox signal of the NTA/Cu2+ complex an efficient electrochemical immunosensor for the evaluation of wide range of D-dimer concentrations was obtained.
引用
收藏
页码:636 / 643
页数:8
相关论文
共 25 条
[11]   Characterisation by immobilised metal ion affinity chromatographic procedures of the binding behaviour of several synthetic peptides designed to have high affinity for Cu(II) ions [J].
Kronina, VV ;
Wirth, HJ ;
Hearn, MTW .
JOURNAL OF CHROMATOGRAPHY A, 1999, 852 (01) :261-272
[12]   The direct electron transfer of glucose oxidase and glucose biosensor based on carbon nanotubes/chitosan matrix [J].
Liu, Y ;
Wang, MK ;
Zhao, F ;
Xu, ZA ;
Dong, SJ .
BIOSENSORS & BIOELECTRONICS, 2005, 21 (06) :984-988
[13]  
Lode P., 2006, THROMB RES, V118, P573
[14]   A neoantigenic determinant in the D-dimer fragment of fibrin [J].
Lugovskoy, EV ;
Kolesnikova, IN ;
Gritsenko, PG ;
Zolotareva, EN ;
Gaffney, P ;
Nieuwenhuizen, W ;
Komisarenko, SV .
THROMBOSIS RESEARCH, 2002, 107 (3-4) :151-156
[15]   Low-potential stable NADH detection at carbon-nanotube-modified glassy carbon electrodes [J].
Musameh, M ;
Wang, J ;
Merkoci, A ;
Lin, YH .
ELECTROCHEMISTRY COMMUNICATIONS, 2002, 4 (10) :743-746
[16]   H2SO4/HNO3/HCl-Functionalization and its effect on dispersion of carbon nanotubes in aqueous media [J].
Osorio, A. G. ;
Silveira, I. C. L. ;
Bueno, V. L. ;
Bergmann, C. P. .
APPLIED SURFACE SCIENCE, 2008, 255 (05) :2485-2489
[17]   Carbon nanotubes for electrochemical biosensing [J].
Rivas, Gustavo A. ;
Rubianes, Maria D. ;
Rodriguez, Marcela C. ;
Ferreyra, Nancy E. ;
Luque, Guillermina L. ;
Pedano, Maria L. ;
Miscoria, Silvia A. ;
Parrado, Concepcion .
TALANTA, 2007, 74 (03) :291-307
[18]   Study on amino-functionalized multiwalled carbon nanotubes [J].
Shen, Jianfeng ;
Huang, Weishi ;
Wu, Liping ;
Hu, Yizhe ;
Ye, Mingxin .
MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 2007, 464 (1-2) :151-156
[19]   Effect of Surface-oxidized Structure of Single-walled Carbon Nanotubes on Heterogeneous Direct Electron-transfer Reaction of Cytochrome c [J].
Tominaga, Masato ;
Yamaguchi, Hiroyuki ;
Sakamoto, Shingo ;
Taniguchi, Isao .
CHEMISTRY LETTERS, 2010, 39 (09) :976-977
[20]   Current and prospective applications of metal ion-protein binding [J].
Ueda, EKM ;
Gout, PW ;
Morganti, L .
JOURNAL OF CHROMATOGRAPHY A, 2003, 988 (01) :1-23