Multiwalled Carbon Nanotubes Modified by NTA-Copper Complex for Label-Free Electrochemical Immunosensor Detection

被引:17
作者
Chebil, S. [1 ,2 ]
Macauley, N. [1 ,2 ,3 ]
Hianik, T. [3 ]
Korri-Youssoufi, H. [1 ,2 ]
机构
[1] Univ Paris 11, CNRS UMR 8182, ICMMO, ECBB, F-91405 Orsay, France
[2] Univ Paris 11, F-91405 Orsay, France
[3] Comenius Univ, Fac Math Phys & Informat, Dept Nucl Phys & Biophys, Bratislava 84248, Slovakia
关键词
Biosensors; Deep vein thrombosis; Label-free detection; MWCNT; NTA; copper; DIRECT ELECTRON-TRANSFER; D-DIMER; BINDING; BIOSENSORS; PROTEINS; AFFINITY;
D O I
10.1002/elan.201200298
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A biomaterial based on multiwalled carbon nanotubes (MWCNTs) modified with His-tagged single chain D-dimer antibody trough nitrilo-triacetic-acid (NTA)/copper complex was designed for monitoring D-dimers, which were used as biomarkers of Deep Vein Thrombosis (DVT). The immunosensing evaluation of D-Dimer was followed by measuring the redox process of such complex. We demonstrate that using simple chemistry and exploiting the high surface area, electronic properties of MWCNTs and redox signal of the NTA/Cu2+ complex an efficient electrochemical immunosensor for the evaluation of wide range of D-dimer concentrations was obtained.
引用
收藏
页码:636 / 643
页数:8
相关论文
共 25 条
  • [1] Nanotubes from carbon
    Ajayan, PM
    [J]. CHEMICAL REVIEWS, 1999, 99 (07) : 1787 - 1799
  • [2] Enzyme-coated carbon nanotubes as single-molecule biosensors
    Besteman, K
    Lee, JO
    Wiertz, FGM
    Heering, HA
    Dekker, C
    [J]. NANO LETTERS, 2003, 3 (06) : 727 - 730
  • [3] Dense monolayers of metal-chelating ligands covalently attached to carbon electrodes electrochemically and their useful application in affinity binding of histidine-tagged proteins
    Blankespoor, R
    Limoges, B
    Schöllhorn, B
    Syssa-Magalé, JL
    Yazidi, D
    [J]. LANGMUIR, 2005, 21 (08) : 3362 - 3375
  • [4] Impedimetric immunosensor based on SWCNT-COOH modified gold microelectrodes for label-free detection of deep venous thrombosis biomarker
    Bourigua, S.
    Hnaien, M.
    Bessueille, F.
    Lagarde, F.
    Dzyadevych, S.
    Maaref, A.
    Bausells, J.
    Errachid, A.
    Renault, N. Jaffrezic
    [J]. BIOSENSORS & BIOELECTRONICS, 2010, 26 (04) : 1278 - 1282
  • [5] Screen-printed electrodes based on carbon nanotubes and cytochrome P450scc for highly sensitive cholesterol biosensors
    Carrara, Sandro
    Shumyantseva, Victoria V.
    Archakov, Alexander I.
    Samori, Bruno
    [J]. BIOSENSORS & BIOELECTRONICS, 2008, 24 (01) : 148 - 150
  • [6] Electrochemical detection of D-dimer as deep vein thrombosis marker using single-chain D-dimer antibody immobilized on functionalized polypyrrole
    Chebil, S.
    Hafaiedh, I.
    Sauriat-Dorizon, H.
    Jaffrezic-Renault, N.
    Errachid, A.
    Ali, Z.
    Korri-Youssoufi, H.
    [J]. BIOSENSORS & BIOELECTRONICS, 2010, 26 (02) : 736 - 742
  • [7] Validation of a new D-dimer microparticle enzyme immunoassay (AxSYM D-Dimer) in patients with suspected pulmonary embolism (PE)
    Ghanima, W.
    Sandset, P. M.
    [J]. THROMBOSIS RESEARCH, 2007, 120 (04) : 471 - 476
  • [8] Non-covalent biofunctionalization of single-walled carbon nanotubes via biotin attachment by π-stacking interactions and pyrrole polymerization
    Haddad, R.
    Cosnier, S.
    Maaref, A.
    Holzinger, M.
    [J]. ANALYST, 2009, 134 (12) : 2412 - 2418
  • [9] Johannsson A., 1991, Principles and Practice of Immunoassay
  • [10] Kim YS, 2006, SYNTHETIC MET, V156, P938, DOI 10.1016/j.synthmet.2006.06.003