Changes in total and segmental extracellular and intracellular volumes with hypotension during hemodialysis measured with bioimpedance spectroscopy

被引:6
|
作者
Haroon, Sabrina [1 ]
Tai, Bee Choo [2 ]
Yeo, Xier [3 ]
Davenport, Andrew [4 ]
机构
[1] Natl Univ Singapore Hosp, Div Nephrol, Level 10,NUHS Tower Block,1E Kent Ridge Rd, Singapore 119228, Singapore
[2] Natl Univ Singapore, Saw Swee Hock Sch Publ Hlth, Singapore, Singapore
[3] Natl Univ Singapore Hosp, Epidemiol Unit, Singapore, Singapore
[4] UCL, Royal Free Hosp, UCL Ctr Nephrol, London, England
关键词
bioelectrical impedance analysis; end stage renal failure; hemodialysis; intradialytic hypotension; ultrafiltration; BIOELECTRICAL-IMPEDANCE ANALYSIS; BLOOD-VOLUME; INTRADIALYTIC HYPOTENSION; BODY-COMPOSITION; PRESSURE; DIALYSIS; MORTALITY; RISK; ULTRAFILTRATION; ASSOCIATION;
D O I
10.1111/aor.14096
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background Bioelectrical impedance analysis (BIA) devices have been advocated to guide volume management in hemodialysis (HD) patients. We hypothesized that understanding the dynamics of fluid shifts in different body segments may provide additional insight on preventive measures to reduce the risk of intradialytic hypotension. Methods A prospective observational study was conducted among 42 HD patients at risk of hypotension who were admitted as emergencies inpatient. Results A total of 191 BIA measurements were made during the 42 HD sessions, and hypotension occurred during 52 measurements (27%). The extracellular water (ECW) to intracellular water ratio (EIR) was measured in different body segments and declined significantly only in the non-access arm with increasing HD session duration (beta = -0.04; 95% confidence interval (CI): -0.05 to -0.03, p < 0.01). There was no significant association between EIR and hypotension with respect to the different body segments. Only pre-HD N-terminal-pro b-type natriuretic peptide was significantly associated with hypotension (beta = 0.20, 95% CI: 0.04 to 0.89, p = 0.04). There was no association between relative blood volume monitoring change and EIR. Conclusion In summary, we found that segmental BIA during HD was unable to detect or predict hypotension during dialysis. Although BIA is able to provide information about ECW and guide clinical assessment of volume in HD patients prior to dialysis, our findings did not suggest the use of serial measurements of changes in EIR in different body segments during HD provided sufficient information to predict intradialytic hypotension. Similarly, changes in EIR did not provide information on changes in plasma volume that could potentially trigger interventions to prevent or reduce intra-dialytic hypotension.
引用
收藏
页码:666 / 676
页数:11
相关论文
共 30 条
  • [21] Differences in tissue oxygenation and changes in total hemoglobin signal strength in the brain, liver, and lower-limb muscle during hemodialysis
    Ookawara, Susumu
    Ito, Kiyonori
    Ueda, Yuichiro
    Miyazawa, Haruhisa
    Hayasaka, Hideyuki
    Kofuji, Masaya
    Uchida, Takayuki
    Ishii, Hiroki
    Shindo, Mitsutoshi
    Kitano, Taisuke
    Aomatsu, Akinori
    Hirai, Keiji
    Kaku, Yoshio
    Hoshino, Taro
    Tabei, Kaoru
    Morishita, Yoshiyuki
    JOURNAL OF ARTIFICIAL ORGANS, 2018, 21 (01) : 86 - 93
  • [22] VALIDATION-STUDY OF THORACIC FLUID BIOIMPEDANCE FOR ASSESSING THE HEMODIALYSIS-INDUCED CHANGES IN TOTAL-BODY FLUIDS
    GRAZIANI, G
    BADALAMENTI, S
    COMO, G
    AMBROSO, G
    GAZZANO, G
    FINAZZI, S
    MANGIAROTTI, R
    MORGANTI, A
    BLOOD PURIFICATION, 1994, 12 (02) : 106 - 112
  • [23] Total body water changes after an exercise intervention tracked using bioimpedance spectroscopy: A deuterium oxide comparison
    Moon, Jordan R.
    Smith, Abbie E.
    Tobkin, Sarah E.
    Lockwood, Christopher M.
    Kendall, Kristina L.
    Graef, Jennifer L.
    Roberts, Michael D.
    Dalbo, Vincent J.
    Kerksick, Chad M.
    Cramer, Joel T.
    Beck, Travis W.
    Stout, Jeffrey R.
    CLINICAL NUTRITION, 2009, 28 (05) : 516 - 525
  • [24] Do Pre-Hemodialysis Estimates of Extracellular Volume Excess Using Bioimpedance and N-Terminal Brain Natriuretic Peptide Correlate With Cardiac Chamber Size Measured by Magnetic Resonance Imaging?
    Yoowannakul, Suree
    Kotecha, Tushar
    Fontana, Marianna
    Davenport, Andrew
    THERAPEUTIC APHERESIS AND DIALYSIS, 2019, 23 (04) : 362 - 368
  • [25] Novel equations for bioimpedance spectroscopy to calculate body fluid volume based on the agreement between body weight and extracellular water change before and after hemodialysis as a guide
    Yashiro, Masatomo
    Kotera, Hirohisa
    RENAL REPLACEMENT THERAPY, 2019, 5 (01)
  • [26] Novel equations for bioimpedance spectroscopy to calculate body fluid volume based on the agreement between body weight and extracellular water change before and after hemodialysis as a guide
    Masatomo Yashiro
    Hirohisa Kotera
    Renal Replacement Therapy, 5
  • [27] Prefrontal hemodynamic changes measured using near-infrared spectroscopy during the Valsalva maneuver in patients with orthostatic intolerance
    Kim, Yoo Hwan
    Phillips, Zephaniah, V
    Paik, Seung-ho
    Jeon, Nam-Joon
    Kim, Beop-Min
    Kim, Byung-Jo
    NEUROPHOTONICS, 2018, 5 (01)
  • [28] Differences in tissue oxygenation and changes in total hemoglobin signal strength in the brain, liver, and lower-limb muscle during hemodialysis
    Susumu Ookawara
    Kiyonori Ito
    Yuichiro Ueda
    Haruhisa Miyazawa
    Hideyuki Hayasaka
    Masaya Kofuji
    Takayuki Uchida
    Hiroki Ishii
    Mitsutoshi Shindo
    Taisuke Kitano
    Akinori Aomatsu
    Keiji Hirai
    Yoshio Kaku
    Taro Hoshino
    Kaoru Tabei
    Yoshiyuki Morishita
    Journal of Artificial Organs, 2018, 21 : 86 - 93
  • [29] Changes in cerebral oxygenation and cerebral blood flow during hemodialysis - A simultaneous near-infrared spectroscopy and positron emission tomography study
    Polinder-Bos, Harmke A.
    Elting, Jan Willem J.
    Aries, Marcel J. H.
    Garcia, David Vallez
    Willemsen, Antoon T. M.
    van Laar, Peter J.
    Kuipers, Johanna
    Krijnen, Wim P.
    Slart, Riemer H. J. A.
    Luurtsema, Gert
    Westerhuis, Ralf
    Gansevoort, Ron T.
    Gaillard, Carlo A. J. M.
    Franssen, Casper F. M.
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2020, 40 (02) : 328 - 340
  • [30] Cerebral oxygenation measured by near-infrared spectroscopy and jugular vein oxygen saturation during robotic-assisted laparoscopic radical prostatectomy under total intravenous anaesthesia
    Kumagai, Motoi
    Ogawa, Shohei
    Doe, Aya
    Suzuki, Kenji
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2015, 11 (03) : 302 - 307