Series Arc Detection and Complex Load Recognition Based on Principal Component Analysis and Support Vector Machine

被引:74
作者
Jiang, Jun [1 ,2 ]
Wen, Zhe [1 ]
Zhao, Mingxin [1 ]
Bie, Yifan [1 ]
Li, Chen [3 ]
Tan, Mingang [1 ]
Zhang, Chaohai [1 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Ctr More Elect Aircraft Power Syst, Nanjing 211106, Jiangsu, Peoples R China
[2] Nanjing Univ Aeronaut & Astronaut, Jiangsu Key Lab New Energy Generat & Power Conver, Nanjing 211106, Jiangsu, Peoples R China
[3] State Grid Zhejiang Elect Power Co Ltd, Res Inst, Hangzhou 310014, Zhejiang, Peoples R China
来源
IEEE ACCESS | 2019年 / 7卷
关键词
Series arc faults; dimensionality reduction; support vector machine; load recognition; arc detection; FAULT-DETECTION; SYSTEM; LINES;
D O I
10.1109/ACCESS.2019.2905358
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The increasing household loads make series arc faults more complex, which are difficult to be detected by traditional circuit breakers and lead to the frequent occurrence of residential fire accidents. In this paper, a comprehensive approach of complex load recognition and series arc detection is proposed on the basis of principal component analysis and support vector machine (PCA-SVM) combination model. Several typical loads were selected and analyzed, especially nonlinear and complex loads like power electronics load and multi-state load. Three time-domain parameters, maximum slip difference (MSD), zero current period (ZCP) and maximum Euclidean distance (MED), and nine frequency-domain harmonics information are collected to complex waveforms. To decrease the computation cost and further to enhance the response velocity, all the time-domain and frequency-domain information were blended and dimensionally reduced to three parameters by principal component analysis (PCA). Prior to the series arc detection, load recognition is trained and completed with the artificial intelligence (AI) algorithm. At last, the comprehensive model of load recognition and series arc detection is achieved based on a support vector machine (SVM). The accuracy of load recognition and series arc detection reaches 99.1% and 99.3%, respectively, demonstrating the excellent performances of the intelligent approach to diagnose the series arcing activities in modern household applications.
引用
收藏
页码:47221 / 47229
页数:9
相关论文
共 28 条
[1]  
[Anonymous], 2013, 626062013 IEC
[2]   Arc Fault Detection Method Based on CZT Low-Frequency Harmonic Current Analysis [J].
Artale, Giovanni ;
Cataliotti, Antonio ;
Cosentino, Valentina ;
Di Cara, Dario ;
Nuccio, Salvatore ;
Tine, Giovanni .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2017, 66 (05) :888-896
[3]   Research on Series Arc Fault Detection Based on High-Order Cumulants [J].
Bao, Guanghai ;
Jiang, Run ;
Liu, Dejun .
IEEE ACCESS, 2019, 7 :4586-4597
[4]  
Cheng HH, 2010, PROCEEDINGS OF THE ASME INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE, VOL 3, P1
[5]  
Gao HX, 2017, ELECTR CONTACT, P325, DOI 10.1109/HOLM.2017.8088107
[6]   Deep-Learning-Based Earth Fault Detection Using Continuous Wavelet Transform and Convolutional Neural Network in Resonant Grounding Distribution Systems [J].
Guo, Mou-Fa ;
Zeng, Xiao-Dan ;
Chen, Duan-Yu ;
Yang, Nien-Che .
IEEE SENSORS JOURNAL, 2018, 18 (03) :1291-1300
[7]   Online Condition Monitoring of MV Switchgear Using D-Dot Sensor to Predict Arc-Faults [J].
Hussain, Ghulam Amjad ;
Shafiq, Muhammad ;
Lehtonen, Matti ;
Hashmi, Murtaza .
IEEE SENSORS JOURNAL, 2015, 15 (12) :7262-7272
[8]   Optimal Design of a Band Pass Filter and an Algorithm for Series Arc Detection [J].
Ji, Hong-Keun ;
Wang, Guoming ;
Kim, Woo-Hyun ;
Kil, Gyung-Suk .
ENERGIES, 2018, 11 (04)
[9]   A novel fault-detection technique of high-impedance arcing faults in transmission lines using the wavelet transform [J].
Kim, CH ;
Kim, H ;
Ko, YH ;
Byun, SH ;
Aggarwal, RK ;
Johns, AT .
IEEE TRANSACTIONS ON POWER DELIVERY, 2002, 17 (04) :921-929
[10]  
Lezama J, 2014, ELECTR CONTACT, P19